Powerware 650825 kVA - Manual

Powerware 650825 kVA

Powerware 650825 kVA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111
112 Page 112
113 Page 113
114 Page 114
115 Page 115
116 Page 116
117 Page 117
118 Page 118
119 Page 119
120 Page 120
121 Page 121
122 Page 122
123 Page 123
124 Page 124
125 Page 125
126 Page 126
127 Page 127
128 Page 128
129 Page 129
130 Page 130
131 Page 131
132 Page 132
133 Page 133
134 Page 134
135 Page 135
136 Page 136
137 Page 137
138 Page 138
139 Page 139
140 Page 140
141 Page 141
142 Page 142
143 Page 143
144 Page 144
145 Page 145
146 Page 146
147 Page 147
148 Page 148
149 Page 149
150 Page 150
151 Page 151
152 Page 152
153 Page 153
154 Page 154
155 Page 155
156 Page 156
157 Page 157
158 Page 158
159 Page 159
160 Page 160
161 Page 161
162 Page 162
163 Page 163
164 Page 164
165 Page 165
166 Page 166
167 Page 167
168 Page 168
169 Page 169
170 Page 170
171 Page 171
172 Page 172
173 Page 173
174 Page 174
175 Page 175
176 Page 176
177 Page 177
178 Page 178
179 Page 179
180 Page 180
181 Page 181
182 Page 182
183 Page 183
184 Page 184
185 Page 185
186 Page 186
187 Page 187
188 Page 188
189 Page 189
190 Page 190
191 Page 191
192 Page 192
Page: / 192

Table of Contents:

  • Page 3 – Table of Contents; Introduction
  • Page 4 – Installing Options and Accessories
  • Page 5 – Communication
  • Page 6 – 0 Product Specifications; Model Numbers; Warranty
  • Page 7 – List of Figures
  • Page 9 – Figure 8-3. Remote Monitor Panel II Front Panel
  • Page 10 – This page intentionally left blank.
  • Page 11 – Chapter 1; Eaton’s Powerware; NOTE; UPS Standard Features; Installation Features; Sections can be permanently bolted to the floor.
  • Page 12 – Control Panel; Building Alarm Monitoring
  • Page 13 – Alarm Contact; Advanced Battery Management
  • Page 14 – Options and Accessories; Field Installed UPM; X−Slot Cards
  • Page 15 – Single−Feed Kit; Controller Area Network (CAN) Bridge Card; Input Output Module Configuration; Battery System
  • Page 16 – Basic System Configurations; Bold type; UPS
  • Page 17 – For More Information; Refer to the
  • Page 18 – Getting Help; Call your local service representative
  • Page 19 – Chapter 2; IMPORTANT SAFETY INSTRUCTIONS; This UPS contains
  • Page 21 – Section I
  • Page 23 – Chapter 3; Use the following basic sequence of steps to install the UPS:; Creating an Installation Plan; Environmental and Installation Considerations; The UPS system installation must meet the following guidelines:
  • Page 24 – Ambient Temperature Range:
  • Page 28 – Figure 3-8. ISBM Section Center of Gravity; Figure 3-9. UPM Section Center of Gravity
  • Page 29 – Figure 3-10. Remote EPO Switch Dimensions
  • Page 30 – UPS System Power Wiring Preparation; For external wiring, use 90
  • Page 34 – Table 3-8. Supplied Intercabinet Wiring Terminal Hardware Kit
  • Page 35 – these power cable terminations.
  • Page 36 – Table 3-10. Supplied External Wiring Terminal Hardware Kit
  • Page 37 – Conduit sizes listed are for copper wiring only.; Table 3-13. Power Cable Conduit Requirements
  • Page 38 – Table 3-14. Recommended Input Circuit Breaker Ratings
  • Page 40 – There is no manual DC disconnect device within the UPS.
  • Page 41 – UPS System Interface Wiring Preparation; Use twisted-pair wires for each input and return or common.
  • Page 42 – Alarm relay wiring should be a minimum of 22 AWG.; Distributed Bypass Power Wiring Preparation
  • Page 43 – Inspecting and Unpacking the UPS Cabinets
  • Page 44 – Remove the protective covering from the cabinets.
  • Page 47 – Chapter 4; Preliminary Installation Information; Installation should be performed only by qualified personnel.; Refer to the following while installing the UPS system:; Unloading the UPS Sections from the Pallet; Do not tilt cabinets more than 10° from vertical.
  • Page 48 – Figure 4-1. Removing the ISBM Section Left Side Shipping Bracket
  • Page 49 – Figure 4-2. Removing the ISBM Section Right Side Shipping Bracket; Repeat Steps 2 through 6 for the remaining cabinet.
  • Page 50 – Figure 4-3. Removing the UPM Section Left Side Shipping Bracket
  • Page 51 – Figure 4-4. Removing the UPM Section Right Side Shipping Bracket; Mechanically Joining the Sections
  • Page 54 – Figure 4-7. ISBM Section to UPM Section Joining Brackets; Electrically Connecting the Sections
  • Page 56 – Reinstall the front wireway panel.
  • Page 61 – Figure 4-12. ISBM Section Battery Input Power Terminal Detail; Figure 4-13. ISBM Section Output Power Terminal Detail
  • Page 62 – Figure 4-14. UPS Intercabinet Interface Harness Locations
  • Page 63 – Figure 4-15. Pl1 Interface Board Location; Figure 4-16. J39 Location on Pl1 Interface Board
  • Page 64 – Field Installed UPM Installation; Powerware; Battery System Installation; External Power Wiring Installation; To install wiring to connections:
  • Page 65 – Figure 4-17. ISBM and UPM Section Debris Shields
  • Page 66 – Figure 4-18. ISBM Section Conduit and Wire Entry Locations; Remove the top conduit plate from the top of the ISBM
  • Page 68 – Figure 4-19. Distributed Bypass Wire Length
  • Page 73 – Figure 4-24. UPM Rectifier Input Power Terminal Block Detail
  • Page 74 – Battery Power Wiring
  • Page 75 – Figure 4-25. ISBM Section Power Terminal Detail BB – Common Battery
  • Page 77 – Installing Interface Connections
  • Page 78 – Close the door and secure the latch.; Figure 4-27. ISBM Section Interface Terminal Locations
  • Page 80 – Figure 4-29. Typical Alarm Relay Connection
  • Page 82 – TB1 Battery Interface Connections; Reinstall the interface entry plate and install the conduit.
  • Page 84 – X−Slot Connections
  • Page 85 – Installing a REPO Switch; for wiring the switch.; To Install a REPO switch:
  • Page 86 – Reinstall the interface entry plate and install conduit.; Figure 4-35. Normally−Open REPO Switch Wiring
  • Page 88 – Initial Startup
  • Page 89 – Installation Checklist
  • Page 90 – Distributed Bypass Installation Checklist; All power cables are properly sized and terminated.
  • Page 91 – Notes
  • Page 93 – Chapter 5; Installing an Optional Powerware Hot Sync CAN Bridge Card; Figure 5-1. Powerware Hot Sync CAN Bridge Card
  • Page 95 – Figure 5-2. Powerware Hot Sync CAN Bridge Card Connections
  • Page 96 – Installing Distributed Bypass Control Wiring; To install distributed bypass control wiring:
  • Page 97 – Figure 5-4. Distributed Bypass System UPS CAN Wiring without MOBs
  • Page 98 – Figure 5-5. Distributed Bypass Pull−Chain Wiring without MOBs
  • Page 99 – Figure 5-6. Distributed Bypass Pull−Chain Wiring with MOBs
  • Page 100 – Table 5-4. Pull−Chain Wiring Terminations with MOBs
  • Page 101 – Installing an Optional Remote Monitor Panel II; To install RMP II wiring:; Reinstall the conduit landing plate.; Close the front door and secure the latch.
  • Page 103 – Installing an Optional Relay Interface Module II; To install RIM II wiring:
  • Page 105 – Installing an Optional Supervisory Contact Module II; To install SCM II wiring:
  • Page 106 – Figure 5-11. Supervisory Contact Module II TB2
  • Page 107 – Accessory Mounting Dimensions; Figure 5-12. Remote Monitor Panel II Dimensions
  • Page 108 – Figure 5-13. Relay Interface Module II Dimensions
  • Page 109 – Figure 5-14. Supervisory Contact Module II Dimensions
  • Page 111 – Section II
  • Page 113 – Chapter 6; UPS System Overview; Figure 6-1. Main Elements of the UPS System; backup battery supply
  • Page 114 – Single UPS; Modes
  • Page 115 – Figure 6-2. Path of Current Through the UPS in Normal Mode
  • Page 116 – Bypass Mode; Figure 6-3. Path of Current Through the UPS in Bypass Mode
  • Page 117 – Battery Mode
  • Page 118 – Figure 6-4. Path of Current Through the UPS in Battery Mode
  • Page 119 – Single UPS Unit System Oneline Configurations
  • Page 133 – Multiple UPS Distributed Bypass System; UPMs are connected with their; Multiple UPS Parallel System Modes
  • Page 134 – command; Normal Mode – Distributed Bypass
  • Page 135 – Bypass Mode – Distributed Bypass
  • Page 136 – Battery Mode – Distributed Bypass
  • Page 138 – Multiple UPS Distributed Bypass System Oneline Configurations
  • Page 143 – Chapter 7; This section describes how to operate the UPS.; UPS Controls and Indicators; Figure 7-1. UPS Controls and Indicators – ISBM Section Shown
  • Page 144 – Using the Control Panel; The control panel consists of:
  • Page 145 – Status Indicators; status indicators; System Events; EVENTS
  • Page 146 – Using the LCD and Pushbuttons; METERS; UPS status
  • Page 147 – Using the Menu; Mimic Screen; pushbutton on the; CONTROLS
  • Page 148 – Display Menu Operation; Table 7-3 describes the menu functions and and how to use them.
  • Page 150 – System Status Screen and Controls; Press the; Figure 7-5. Typical System Status Screen
  • Page 151 – Table 7-4. Typical System Status Messages
  • Page 152 – Load Off Screen; HOLD LOAD OFF BUTTON FOR 3 SECONDS
  • Page 153 – Single UPS Operation; Starting the UPS in Normal Mode; SHUTDOWN
  • Page 154 – Starting the UPS in Bypass Mode
  • Page 156 – Transfer from Normal to Bypass Mode; ON; Power is present inside the UPS cabinet sections.; Transfer from Bypass to Normal Mode; ONLINE
  • Page 157 – Transfer from Normal to Bypass Mode and Shut Down UPS; Single UPM Shutdown
  • Page 158 – UPS and Critical Load Shutdown
  • Page 159 – Using the UPS LOAD OFF Pushbutton or Command
  • Page 160 – Using the Remote Emergency Power−off Switch
  • Page 162 – Multiple UPS Distributed Bypass Operation; Starting the Distributed Bypass System in Normal Mode
  • Page 163 – Starting the Distributed Bypass System in Bypass Mode
  • Page 166 – Transfer from Normal to Bypass Mode and Shut Down all UPSs
  • Page 171 – Chapter 8; Modem Card
  • Page 172 – eNotify Service; Support Agreement after the initial; eNotify Service Features
  • Page 173 – Powerware LanSafe Power Management Software; Four separate, programmable notification groups (phone numbers)
  • Page 174 – Call Answer; Terminal Mode; In Terminal mode, the user can request the following functions:; Display UPS Control Panel
  • Page 175 – Event History Log; mode is always in English.
  • Page 177 – Contacts should not be operated in excess of 30 Vac @ 5A maximum.; Remote Monitor Panel II
  • Page 179 – Relay Interface Module II
  • Page 180 – Supervisory Contact Module II; Figure 8-5. Supervisory Contact Module II Enclosure; The SCM II provides signals for the indications shown in Table 8-3.; Table 8-3. SCM II Status Indicators and Connections
  • Page 181 – Chapter 9; Important Safety Instructions; EVEN WHEN
  • Page 182 – Performing Preventive Maintenance; DAILY Maintenance; Perform the following steps daily:; MONTHLY Maintenance; Perform the following steps monthly:
  • Page 183 – Figure 9-1. ISBM Section Air Filter Locations
  • Page 184 – Figure 9-2. UPM Section Air Filter Locations; Powerware 9395 Field Installed UPM Mechanical; Verify washed filter is thoroughly dry before reinstalling.
  • Page 185 – PERIODIC Maintenance; Installing Batteries
  • Page 186 – Recycling the Used Battery or UPS
  • Page 187 – Product Specifications; UPS Input
  • Page 188 – UPS Output; UPS Environmental
  • Page 189 – LIMITED FACTORY WARRANTY FOR THREE-PHASE POWERWARE
Loading the manual

Powerware 9395 UPS and Plus 1 UPS
650–825 kVA
Installation and Operation Manual

®

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Table of Contents; Introduction

EATON Powerware ® 9395 UPS (650–825 kVA) Installation and Operation Manual S 164201725 Rev 2 www.powerware.com i Table of Contents 1 Introduction 1−1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 4 - Installing Options and Accessories

TABLE OF CONTENTS EATON Powerware ® 9395 UPS (650–825 kVA) Installation and Operation Manual S 164201725 Rev 2 www.powerware.com ii 4.8 Installing UPS External and Battery Power Wiring 4−18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 5 - Communication

TABLE OF CONTENTS EATON Powerware ® 9395 UPS (650–825 kVA) Installation and Operation Manual S 164201725 Rev 2 www.powerware.com iii 7.3 Single UPS Operation 7−11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

Other Powerware Models

All Powerware Other