Peavey 1264 H - Manual
Peavey 1264 H – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Beamwidth; Figure 3; Impedance; Figure 2; Q & Directivity Index; Figure 4; Figure 1
- Page 3 – capabilities; Applications; The Peavey ILS 1264 is a high; Figure 5; Figure 6
- Page 5 – Horizontal Polar Patterns 6 dB per Division
- Page 7 – Vertical Polar Patterns 6 dB per Division
- Page 10 – A PRODUCT OF PEAVEY ELECTRONICS CORP.; FULL RANGE; BIAMP; ILS
Frequency Response, 1 meter
on-axis, swept-sine in anechoic
environment:
63 Hz - 18.5 kHz (±3 dB)
Usable Low Frequency Limit
(-10 dB point):
48 Hz
Power Handling:
Full Range:
700 W continuous
1,400 W program
2,800 W peak
Low Frequency Section:
500 W continuous
1,000 W program
2,000 W peak
High Frequency Section:
100 W continuous
200 W program
400 W peak
Sound Pressure Level, 1 Watt,
1 meter in anechoic
environment
:
Full Range:
96.0 dB SPL, (2.83 V input)
Low Frequency Section:
97.0 dB SPL, (2.83 V input)
High Frequency Section:
109.0 dB SPL, (2.83 V input)
Maximum Sound Pressure Level
(1 meter):
Full Range:
124.5 dB SPL continuous
130.5 dB SPL peak
Low Frequency Section:
124.0 dB SPL continuous
130.0 dB SPL peak
High Frequency Section:
129.0 dB SPL continuous
135.0 dB SPL peak
Radiation Angle measured at
-6 dB point of polar response:
500 Hz – 1.6 kHz:
Horiz.
105
o
± 15
o
Vert.
115
o
± 15
o
1.6 kHz - 5 kHz:
Horiz.
60
o
± 10
o
Vert.
50
o
± 20
o
5 kHz - 16 kHz:
Horiz.
55
o
± 5
o
Vert.
30
o
± 5
o
Directivity Factor, Q (Mean):
16.18 ± 9.18
Directivity Index, Di (Mean):
11.13 dB ± 3.13 dB
Transducer Complement:
Low Frequency Section:
1x 12in. woofer, vented
1208-8 SPS
High Frequency Section:
1x 1.6 in. exit/100 mm voice coil
compression driver on Quadratic
Throat Waveguide
™
44 XT (w/o adapter) on a CH
®
-
642qt
Box Tuning Frequency:
Low Frequency Section:
55 Hz
Harmonic Distortion:
1% rated power
2nd Harmonic:
100 Hz:
3.22%
1 kHz:
0.52%
S
P
E
C
I
F
I
C
A
T
I
O
N
S
ILS
™
1264H
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
3rd Harmonic: 100 Hz: 0.29% 1 kHz: 0.30% 10% rated power2nd Harmonic: 100 Hz: 7.40% 1 kHz: 2.24% 3rd Harmonic: 100 Hz: 1.96% 1 kHz: 0.40% Crossover Frequency (internalpassive): Low Frequency - High Frequency: 1,900 Hz Time Offset: Low Frequency: 0.00 ms High Frequency: 0.81 ms Impedance (Z): Full Ra...
3 • Flexible suspension provisions• Robust power handling capabilities • Passive crossover included• Bi-amplified crossover provisions Applications • Stadiums• Arenas• Multi-purpose facilities• Cruise ships• Theme parks• Houses of worship• Live music venues• Hotel meeting rooms• Conference facilitie...
-90 o -60 o -30 o 0 o 30 o 60 o 90 o 200 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 315 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 500 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 800 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1.25 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 ...