PASCO PS-2170 - Manual

PASCO PS-2170

PASCO PS-2170 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – Optional Equipment; Temperature
  • Page 3 – S e n s o r , I n t e r f a c e , a n d S o f t w a r e S e t u p; Computer Setup; Using PASCO Capstone; ) in the Tools palette to; In the Graph display screen, click the green Record button (; Wireless Setup; Using SPARKvue HD; In the Graph display screen, touch the green Record button (
  • Page 4 – Using the SPARK SLS; Press the; Check; ) to change the visibility of that measurement. (You can also; Calibration Information; Te m p e r a t u r e; thermistor; Measuring Temperature; Temperature Calibration
  • Page 5 – Measuring pH; Cleaning
  • Page 6 – P r e s s u r e; Vo l t ag e
  • Page 7 – S p e c i f i c a t i o n s
  • Page 8 – A p p e n d i x A : PA S C O C a p s t o n e C a l i b r a t i o n
  • Page 9 – A p p e n d i x B : S PA R K v u e H D C a l i b r a t i o n; Touch “Temperature” and then touch “Show”.
  • Page 10 – A p p e n d i x C : S PA R K S L S C a l i b r a t i o n
  • Page 12 – Te ch n i c a l S u p p o r t; For assistance with any PASCO product, contact PASCO at:; Product End of Life Disposal Instructions:; Address: PASCO scientific
Loading the manual

I n s t r u c t i o n M a n u a l

0 1 2 - 0 9 5 2 3 B

C h e m i s t r y M u l t i M e a s u r e S e n s o r

P S - 2 1 7 0

Included Equipment

Model Number

1. Chemistry MultiMeasure Sensor

PS-2170

2. Stainless Steel Temperature Probe

PS-2153

3. Voltage Probe

PS-2165

4. pH Electrode

PS-2573

5. Polyurethane Tubing (60 cm, 0.125 inch ID)

6. Quick-release Connectors (qty. 4)

Hose and Coupling Kit

7. Tubing Connectors (qty. 4)

8. Syringe (60 cc)

9. Alligator Clip with Insulator (qty. 2 each)

Polyurethane Tubing, (blue, 15 cm, 0.25 inch OD)

not shown

Required Equipment

Note

PASPORT Interface and
Data Acquisition Software

See PASCO catalog or

www.pasco.com

CHEMISTR

Y

PS-2170

ä

SENSO

R

PRESSURE

pH/ISE/ORP

VOLTA

GE

TEMPERA

TURE

1

2

3

4

5

6

7

8

9

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Optional Equipment; Temperature

C h e m i s t r y M u l t i M e a s u r e S e n s o r I n t r o d u c t i o n 2 012-09523B I n t ro d u c t i o n The PS-2170 Chemistry MultiMeasure Sensor combines four sensors in a single unit: The sensor includes a temperature probe, a voltage probe, and a pH electrode. The pressure sensing eleme...

Page 3 - S e n s o r , I n t e r f a c e , a n d S o f t w a r e S e t u p; Computer Setup; Using PASCO Capstone; ) in the Tools palette to; In the Graph display screen, click the green Record button (; Wireless Setup; Using SPARKvue HD; In the Graph display screen, touch the green Record button (

M o d e l N o . P S - 2 1 7 0 S e n s o r , I n t e r f a c e , a n d S o f t w a r e S e t u p 3 012-09523B Computer Setup Using PASCO Capstone • Connect a PASPORT-compatible interface to the computer and start the PASCO Capstone software. (Refer to the documentation that came with your PASPORT int...

Page 4 - Using the SPARK SLS; Press the; Check; ) to change the visibility of that measurement. (You can also; Calibration Information; Te m p e r a t u r e; thermistor; Measuring Temperature; Temperature Calibration

C h e m i s t r y M u l t i M e a s u r e S e n s o r T e m p e r a t u r e 4 012-09523B Hand-held Setup Using the SPARK SLS • Connect the sensor to a port on the SPARK SLS and turn on the interface. The sensor parameter screen opens and shows the list of measurements for the sensor. • In the sensor...

Other PASCO Models

All PASCO Other