PASCO PS-2190 - Manual
PASCO PS-2190 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – M H z 2 - c h a n n e l V o l t a g e S e n s o r; Sample Rate in the Sensors Screen
- Page 3 – Trigger Settings; ) button to select ‘OK’; Trigger in the Graph Display; tical dashed line appear on the Graph indicating the stop time.; A b o u t t h e S e n s o r; Front Panel Indicators
- Page 4 – B a s i c S p e c i f i c a t i o n s; For assistance with any PASCO product, contact PASCO at:; Address: PASCO scientific
®
I n s t r u c t i o n S h e e t
0 1 2 - 1 0 2 5 3 A
1 M H z 2 - ch a n n e l Vo l t ag e S e n s o r
P S - 2 1 9 0
Included Equipment
•
1 MHz 2-channel Voltage Sensor
Additional Equipment Required
•
Xplorer GLX datalogger (PS-2002)
•
Patch Cords (SE-9750 or SE-9751)
Q u i ck S t a r t
1.
Connect the 1 MHz 2-channel Voltage Sensor to your
PASPORT Xplorer GLX datalogger.
2.
Use patch cords to connect Channel 1 and Channel 2 to the
parts of the circuit for which you want to measure the volt-
age.
3.
On the Xplorer GLX, press the start button (
s
) to begin
recording data.
4.
When data recording is done, press the start button again to
stop recording data.
The sensor measures up to two voltages simultaneously at speeds
up to one million samples per second when used with the GLX in
oscilloscope mode.
I n t ro d u c t i o n
The 1 MHz 2-channel Voltage Sensor is a high speed, two chan-
nel PASPORT voltage sensor that has a basic voltage range of
±10 volts. It has amplifiers that allow full-scale input ranges of
±1 volt and ±0.1 volt. The sensor uses an oversampling scheme
that allows input sampling at speeds up to one million samples
per second.
The 1 MHz 2-channel Voltage Sensor connects to a PASPORT
Xplorer GLX datalogger. Measurements are recorded and dis-
played by the datalogger.
S e t - u p
Connecting the Sensor to an Xplorer GLX
Datalogger
Plug the sensor into any port on the top of the PASPORT Xplorer
GLX datalogger. The Xplorer GLX screen will automatically
show a Graph display of voltage versus time.
Setting Sensor Parameters
Sample rate, data averaging, and input voltage range are set in the
Sensors screen.
•
Press the Home button (
h
) to open the Home screen.
•
Press F4 (
I
) under Sensors in the Home screen to open
the Sensors screen.
Figure 1: Sensor screen
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
® 1 M H z 2 - c h a n n e l V o l t a g e S e n s o r P S - 2 1 9 0 2 The Sensors screen shows the icon and name of the sensor in the upper left corner, and menus for Sample Rate Unit, Sample Rate, Reduce/Smooth Averaging, Channel 1, and Channel 2. Sample Rate in the Sensors Screen By default, the s...
® 1 M H z 2 - c h a n n e l V o l t a g e S e n s o r P S - 2 1 9 0 3 The sample rate is linked to the time resolution on the horizontal axis. For example, when the horizontal axis scale is 0 to 10 ms, the sample rate in the Sensor Settings screen is 20,000 Hz. When the horizontal scale is 0 to 5 ms...
® 1 M H z 2 - c h a n n e l V o l t a g e S e n s o r P S - 2 1 9 0 4 Trigger In-Out The PS-2190 has two BNC connectors on the rear panel labeled Trigger In and Trigger Out. By connecting the Trigger Out of one PS-2190 to the Trigger In of a second PS-2190, the two sensors are time synchronized and ...