I n s t r u c t i o n S h e e t

0 1 2 - 1 2 3 6 0 A

PA S C O O p t i c s

A d j u s t a bl e F o c a l L e n g t h L e n s

O S - 8 4 9 4

800-772-8700

www.pasco.com

*012-12360*

®

Included Equipment

Quantity

1.

Adjustable Focal Length Lens

2

2.

Tubing, 5 mm O.D.

30 cm

3.

10 mL Syringe

1

Related Equipment

Human Eye Model (OS-8477)

Eye Model Bracket (OS-8469)

Adjustable Lens Holder* (OS-8474

Basic Optics Light Source* (OS-8470)

Basic Optics Bench*, 60 cm (OS-8541)

Basic Optics Viewing Screen* (OS-8460)

*Part of Basic Optics System, OS-8515A

See www.pasco.com for other PASCO Optics System equipment.

Introduction

The Adjustable Focal Length Lens includes two lenses, a
length of plastic tubing, and a 10 milliliter (mL) syringe. Each
lens consists of a plastic housing with two flexible membranes
held onto the housing with removable rings. Use the syringe to
fill the lens with a fluid such as water and to increase or
decrease the amount of fluid between the two flexible mem-
branes. By adjusting the curvature of the membranes, you can
adjust the focal length of the lens.

The Adjustable Focal Length Lens is designed to be used with
the PASCO Human Eye Model (OS-8477) to demonstrate

accomodation

, the ability of the eye’s crystalline lens to change

its focal length. It can also be used with components of the
PASCO Basic Optics System (OS-8515A) such as the Light
Source, Optics Bench, Viewing Screen, and Adjustable Lens
Holder.

1

2

3

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Disconnect the syringe from the plastic tubing.

® 2 Assembly and Maintenance Cut a length of tubing about 15 cm (6 inch) long. Adjust the syringe so that the piston is beyond the midpoint of the cylinder. Attach the piece of plastic tubing to the 10 mL syringe and the connector on the edge of the lens housing (see Figure 1). NOTE: Avoid touching ...

Page 3 - Figure 3

® 3 Use with the Human Eye Model Set the Basic Optics Light Source about 5 to 10 cm in front of the Human Eye Model with the “crossed-arrow” target aligned with the opening in the front of the model. Place the retina viewing screen in the “NORMAL” groove. Make sure that the lens is filled with a flu...

Page 4 - Technical Support; For assistance with any PASCO product, contact PASCO at:; Limited Warranty; Copyright; Trademarks; Address: PASCO scientific

® 4 Technical Support For assistance with any PASCO product, contact PASCO at: For the latest revision of this Instruction Sheet, visit: www.pasco.com/go?OS-8494 Limited Warranty For a description of the product warranty, see the PASCO catalog. Copyright The PASCO scientific 012-12360A Adjust- able ...