Table of Contents:
- Page 2 – Exploded View and Replacement Parts List..63
- Page 3 – Safety Precautions; power plug and main circuit for the model installed.
- Page 8 – Location of Controls and Components; Unit
- Page 11 – Refrigeration Cycle Diagram; INDOOR
- Page 13 – Wiring Connection Diagram
- Page 15 – Electronic Circuit Diagram
- Page 17 – Printed Circuit Board
- Page 20 – Instruction; Select the Best Location
- Page 21 – Install a Sleeve of Piping
- Page 23 – Connect the Cable to the Indoor Unit; The inside and outside connecting cable can; Connecting cable; between indoor unit and
- Page 24 – Wire Stripping And Connecting Requirement; Cutting and flaring the piping; end down to avoid the metal powder entering the pipe.
- Page 25 – Please fasten the installation stand firmly with bolt or nails.; the piping to indoor
- Page 28 – Insulation
- Page 29 – Control; Cooling Operation; Cooling operation can be set using remote control.
- Page 30 – Soft Dry Operation; Soft Dry operation can be set using remote control.
- Page 31 – Automatic Operation; Automatic operation can be set using remote control.
- Page 32 – Indoor Fan Speed Control; Cooli
- Page 33 – Indoor Fan Motor rpm Abnormal Control
- Page 34 – shown in the diagram.
- Page 35 – Horizontal Airflow Direction Control; Powerful Operation
- Page 36 – Quiet Operation
- Page 37 – the power is resumed.; Remote Control Signal Receiving Sound
- Page 38 – Operation; Press continously for 15s
- Page 40 – (Applicable to all models except KKD models)
- Page 45 – ECO Patrol Operation
- Page 46 – No setting temperature adjustment.
- Page 49 – Minutes Time Save Control; This phenomenon is to reduce the built up humidity inside a room.; 0 Seconds Forced Operation; full cycle and return back to the outdoor unit.; Starting Current Control; will start to operate at 1.6 seconds later.
- Page 51 – Mode; AUTO OPERATION MODE
- Page 52 – Remote Control Button; Button
- Page 53 – Guide; Refrigeration cycle system
- Page 55 – Disassembly and Assembly Instructions; Removal Procedures
- Page 56 – To remove power electronic controller
- Page 57 – To remove cross flow fan and indoor fan motor
- Page 59 – Data; Operation Characteristics; Cooling
- Page 63 – Exploded View and Replacement Parts List
- Page 65 – “O” marked parts are recommended to be kept in stock.
- Page 67 – Printed in Malaysia
© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2010.
Unauthorized copying and distribution is a violation of law.
Order No: PHAAM1006051C3
Indoor Unit
Outdoor Unit
CS-C18KKS
CS-C24KKS
CU-C18KKS
CU-C24KKS
TABLE OF CONTENTS
1.
Safety Precautions ............................................. 3
2.
Specification ....................................................... 5
3.
Features .............................................................. 7
4.
Location of Controls and Components ........... 8
4.1
Indoor Unit .................................................... 8
4.2
Outdoor Unit ................................................. 8
4.3
Remote Control ............................................ 8
5.
Dimensions ......................................................... 9
5.1
Indoor Unit .................................................... 9
5.2
Outdoor Unit ............................................... 10
6.
Refrigeration Cycle Diagram ........................... 11
7.
Block Diagram .................................................. 12
8.
Wiring Connection Diagram ............................ 13
8.1
CS-C18KKS CU-C18KKS .......................... 13
8.2
CS-C24KKS CU-C24KKS .......................... 14
9.
Electronic Circuit Diagram .............................. 15
9.1
CS-C18KKS CU-C18KKS .......................... 15
9.2
CS-C24KKS CU-C24KKS .......................... 16
10.
Printed Circuit Board .......................................17
10.1
Indoor Unit ..................................................17
11.
Installation Instruction.....................................20
11.1
Select the Best Location ............................20
11.2
Indoor Unit ..................................................21
11.3
Outdoor Unit ...............................................25
12.
Operation Control.............................................29
12.1
Cooling Operation ......................................29
12.2
Soft Dry Operation......................................30
12.3
Automatic Operation ..................................31
12.4
Indoor Fan Speed Control ..........................32
12.5
Outdoor Fan Speed Control .......................34
12.6
Vertical Airflow Direction Control................34
12.7
Horizontal Airflow Direction Control ...........35
12.8
Powerful Operation.....................................35
12.9
Quiet Operation ..........................................36
12.10
Timer Control..............................................37
12.11
Random Auto Restart Control ....................37
12.12
Remote Control Signal Receiving Sound...37
12.13
Patrol Operation .........................................38
12.14
E-ion operation ...........................................42
12.15
ECO Patrol Operation ................................45
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service
or repair the products dealt with in this service information by anyone else could result in serious injury or death.
WARNING
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 13. Protection Control ............................................49 13.1 Restart Control (Time Delay Safety Control).. ....................................................................49 13.2 7 Minutes Time Save Control .....................49 13.3 60 Seconds Forced Operation ...................
3 CAUTION WARNING WARNING 1. Safety Precautions • Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. • Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model installed. •...
8 4. Location of Controls and Components 4.1 Indoor Unit 4.2 Outdoor Unit 4.3 Remote Control