Oregon Scientific BPW128 - Manual
Oregon Scientific BPW128 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – WRIST TYPE BLOOD PRESSURE; USER’S MANUAL; INTRODUCTION; Before use please note:; This device is intended for non-invasive measuring and
- Page 4 – B. Battery compartment; wrapping
- Page 5 – batteries; Replace the batteries if:; When battery power is low, replace all the batteries.
- Page 6 – PROPER EQUIPMENT SETUP; on bare skin for correct measurements.
- Page 7 – WHAT IS MEAN ARTERIAL PRESSURE; Mean Arterial Pressure; OSCILLOMETRIC MEASURING METHOD; the; BLOOD PRESURE DEFINITIONS; Hypertension; professional when blood-pressure
- Page 8 – MEASUREMENT; a seated position. Avoid
- Page 9 – HOW TO TAKE MEASUREMENT; Refer to Fig1
- Page 10 – Refer to Fig2; measurement will be shown first.
- Page 11 – HOW TO SET THE TIME; Refer to Fig3
- Page 12 – AUTOMATIC POWER OFF; The device will automatically; ERROR MESSAGES; Display; ]button for 2 seconds, the display will flash; minutes
- Page 13 – SPECIFICATIONS; Operating environment; MAINTENANCE, CLEANING AND CARE; Here are a few product care instructions:
- Page 14 – WARRANTY; IMPORTANT ADVICE - RETAIN FOR; Please observe user’s manual; Manufacturer
- Page 15 – If the device does not function:; CAUTION; - The content of this manual is subject to change with-
GB
1
mmHg
60
80
100
120
140
160
180
200
220
/ min
2
1
21.2 22.2
85 90
158
92
110
155
93
112
10:05 10:12
x
x
x
x
x
x
LOG BOOK
: Age: Weight: kg/lbs
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
GB 3 INFORMATION CONCERNING THE CE SYMBOL This device complies with the European regulations based on theMedical Products Code, and bears the CE mark “CE0123”. Thedevice has been quality inspected according to EG guideline93/42/EWG and tested in compliance to the EN1060-1Non-invasive sphygmomanomete...
4 GB DESCRIPTION AND FUNCTION OF PARTS A. Liquid Crystal Display (LCD) and protective cover - Large easy-reading display- 5 functional symbols- S y s t o l i c [ S Y S / m m H g ] , D i a s t o l i c [ D I A / m m H g ] , M e a n [MAP/mmHg], Pulse [pul/min.]and date & time display. B. Battery co...
GB 5 DISPLAY-SYMBOL DESCRIPTION Memory Mark Weak Battery Inflating Mark Air releasing Pulse Mark INSTALLING BATTERIES 1. Slide battery cover off. 2. Install batteries first. Ensure correct polarity. Battery Type: 2 Alkaline LR03 (AAA)size 3. Replace the cover. Replace the batteries if: 1. the weak b...