Page 2 - Contents; Before using the unit
2 Before using the unit Contents Before using the unit Introduction ................................................................................................... 3Intended use .................................................................................................. 3Important safety i...
Page 4 - Important safety instructions; respiratory therapist.
4 Important safety instructions Read all the information in the instruction manual and any other literature included in the box before using the device. When using an electrical product, especially when children are present, basic safety precautions should always be followed including the following:...
Page 5 - battery, do not place hair pins or other metal objects in the bag.
5 Important safety instructions EN • Do not use the main unit, AC adapter, optional rechargeable battery, or optional battery charger while they are wet, or connect them to a power outlet or other devices with wet hands. • The compressor, AC adapter, and optional rechargeable battery and charger are...
Page 6 - rechargeable battery or charger.
6 Important safety instructions • Do not leave the unit unattended with infants or persons who cannot express their consent. • Do not subject the device or the parts to any strong shocks such as dropping the device on the floor. • Do not distort the vaporiser head, or jab the nozzle of the medicatio...
Page 7 - General Safety Precautions:; Save these instructions for future reference.
7 Important safety instructions EN General Safety Precautions: • Inspect the device and parts before using them each time, and check that there are no problems. In particular, be sure to check the following:- That the vaporiser head, nozzle or air tube are not damaged.- That the nozzle is not blocke...
Page 8 - D. Inhalation Attachments; Rear View
8 1. Know your unit A. Compressor (Main Unit) A1. Power IndicatorA2. Power SwitchA3. Charge IndicatorA4. Air ConnectorA5. Filter Cover (* Air filter inside.) A6. Nebuliser Kit HolderA7. AC Adapter JackA8. Battery Connector B. Air Tube (PVC, 207cm) B1. Air PlugB2. Air Plug C. Nebulising Parts D. Inha...
Page 10 - Guide to using the Comp Air Elite; Preparing the Nebuliser for Use (Section 3); • Do not tilt the nebuliser kit so that it is at an; How the nebuliser kit works
10 2. Guide to using the Comp Air Elite Preparing the Nebuliser for Use (Section 3) Note: Clean and disinfect the nebuliser kit and applicable inhalation attachments before using the device for the first time, or if it has not been used for more than one week. Taking Medication (Section 4) Notes: • ...
Page 11 - Operating instructions; Preparing the nebuliser for use; Plug the AC adapter into a power outlet.
11 EN Operating instructions 3. Preparing the nebuliser for use Warning: Clean and disinfect the nebuliser kit, mouthpiece and optional nosepiece or masks before using them for the first time after purchase, if the device has not been used for a long period of time, or if more than one person uses t...
Page 12 - Adding medication and assembling the parts; Rotate the inhalation top anti-clockwise.; Caution: The capacity of the medication
12 3. Preparing the nebuliser for use 3.2 Adding medication and assembling the parts 1. Remove the mouthpiece and cap from the nebuliser kit. 2. Remove the inhalation top from the medication tank. 1) Rotate the inhalation top anti-clockwise. 2) Lift the inhalation top out of the medication tank. 3. ...
Page 13 - Attaching the mouthpiece
13 3. Preparing the nebuliser for use EN 5. Reattach the vaporiser head to the medication tank. 6. Put the inhalation top back inside the medication tank. 1) Align the protrusion on the inhalation top with the indent on the medication tank, as shown. 2) Rotate the inhalation top clockwise and align ...
Page 14 - Attaching the nosepiece
14 3. Preparing the nebuliser for use Attaching the child mask (PVC) Attach the mask to the inhalation top. 1) Attach the cap to the inhalation air inlet. 2) Attach the child mask to the inhalation top. Attaching the nosepiece Attach the cap when using the nosepiece. 1) Attach the cap to the inhalat...
Page 15 - Attach the air tube to the air connector on the compressor.
15 3. Preparing the nebuliser for use EN 8. Attach the air tube. 1) Attach the air tube to the air connector on the compressor. 2) Attach the other end of the air tube to the air tube connector on the medication tank. Notes: • Make sure that the air tube is securely attached to the compressor (main ...
Page 16 - To stop nebulisation; Do not block the air filter cover.
16 4. Taking medication 1. Hold the nebuliser kit as indicated on the right. Caution: Do not tilt the nebuliser kit so that it is at an angle of greater than 45°. Medication may flow into the mouth. 2. Press the power switch. The compressor starts and nebulisation starts. Notes: • The green light sh...
Page 19 - Care and maintenance; Cleaning and daily disinfecting; Make sure that the power indicator is out.
19 EN Care and maintenance 5. Cleaning and daily disinfecting 5.1 Cleaning Following the cleaning instructions after each use will prevent any remaining medication in the tank from drying, resulting in the device not nebulising effectively and also for preventing infections. Warning: Thoroughly rins...
Page 20 - Caution: The compressor is not; Nebuliser kit should be replaced after using for 6 months.; Disinfecting the nebulising parts; Remove the parts and discard the solution.; Mild Detergent
20 5. Cleaning and daily disinfecting 6. After cleaning and disinfecting the parts, rinse them thoroughly with clean water and allow the parts to air dry in a clean environment. 7. If the compressor is dirty, wipe it clean with a soft cloth moistened with water or mild detergent. Caution: The compre...
Page 21 - Handling the Vaporiser Head
21 5. Cleaning and daily disinfecting EN Handling the Vaporiser Head The vaporiser head is an important part that is used to vaporise medication.Be sure to observe the following precautions when handling it. Caution: • Always wash the vaporiser head after each use. Failure to do so could cause block...
Page 22 - Maintenance and storage; express their consent.; under direct sunlight.; Benzene
22 6. Maintenance and storage To keep your device in the best condition and protect the device from damage follow these directions: Caution: • Do not leave the unit unattended with infants or persons who cannot express their consent. • Do not subject the device or the parts to any strong shocks such...
Page 23 - Changing the air filter
23 EN 7. Changing the air filter On average, the air filter should be changed every 60 days or so, or when the filter has changed colour from white. 1. Pull the air filter cover off the compressor. 2. Change the air filter. Remove the old air filter with a sharp object, such as a toothpick, and inse...
Page 26 - Operating Temperature/
26 9. Technical data Notes: • Subject to technical modification without prior notice.• This OMRON product is produced under the strict quality system of OMRON Healthcare Co. Ltd., Japan. • The device may not work if the temperature and voltage conditions are different to those defined in the specifi...
Page 27 - ml maximum; Appropriate Medication; ml minimum - 7 ml maximum
27 9. Technical data EN Technical data for the OMRON Comp Air compressor with the OMRON V.V.T. (Virtual Valve Technology) Nebuliser kit: Notes: • Performance may vary with drugs such as suspensions or high viscosity. See drug supplier’s data sheet for further details. • The data above is referenced ...
Page 28 - Read the instruction manual carefully
28 9. Technical data Notes: • Do not use the device where it may be exposed to flammable gas.• This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive) and the European Standard EN13544-1:2007, Respiratory therapy equipment - Part1: Nebulizing systems and their com...
Page 30 - Optional parts and accessories; Kit Set
30 10.Optional parts and accessories OMRON V.V.T. Nebuliser Kit Set Order No. 9956268-9 Air Tube (PVC, 207cm) Order No. 9956270-0 Mouthpiece Order No. 9956273-5 Air Tube (Silicon, 100cm) Order No. 9956269-7 Nosepiece Order No. 9956274-3 Child Mask (SEBS) Set Order No. 9956281-6 Adult Mask (SEBS) Ord...
Page 31 - Optional parts and accessories
31 10. Optional parts and accessories EN Filter Cover Order No.9956638-2 Instruction Manual Order No.9956633-1 Carrying Bag Order No.9956631-5 Battery Set Includes the rechargeable battery, battery charger.Order No.9986453-7 Rechargeable Battery Order No.9986457-0 Battery Charger Order No.9986461-8 ...
Page 32 - Using the battery for; Fully charge the battery.
32 11. Using optional accessories 11.1 Using the optional rechargeable battery Use the rechargeable battery as shown in the chart below. For details, refer to the following pages. Using the battery for the first time. When the battery has not been used for a while. Fully charge the battery. Attach t...
Page 33 - Using optional accessories; Important notes on using the optional rechargeable battery; at the time of shipment.
33 11. Using optional accessories EN 1. Charge the battery. 1) Insert the power connector of the AC adapter into the AC adapter jack on the charger. 2) Plug the AC adapter into a power outlet. Important notes on using the optional rechargeable battery • Charge the battery before using it for the fir...
Page 35 - When battery power is low; • Battery power is low and the device will cease to; If the battery will not be used for a long time
35 11. Using optional accessories EN When battery power is low The charge indicator on the main unit will light when battery power is low. Please note the following points about using the device after the charge indicator lights:• Stop using the device when the charge indicator comes on. • Battery p...
Page 36 - Made in China; THE NETHERLANDS
36 11. Using optional accessories Made in China Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp THE NETHERLANDS www.omron-healthcare.com Production facility OMRON (DALIAN) CO....