Klinkmann Automation Omron Ethernet DAServer i Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 Contents Before You Begin .......................................................................................................... 1 About This User Guide.......................................
Page 3 - Before You Begin; About This User Guide
Klinkmann Automation Omron Ethernet DAServer 1 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 Before You Begin About This User Guide This user’s guide describes the user interface and functions of the KLINKMANN OMRON Ethernet Direct DAServer. It also provides you with the step-by-step ...
Page 4 - CHAPTER 1; Introduction; Overview
Klinkmann Automation Omron Ethernet DAServer 2 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 CHAPTER 1 Introduction This chapter provides you with an overview of the KLINKMANN OMRON Ethernet Direct DAServer, including the application- and bus-level communications protocols, item namin...
Page 5 - Communication Protocols; Application Communications Protocols
Klinkmann Automation Omron Ethernet DAServer 3 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 Microsoft Windows program capable of acting as a DDE, SuiteLink ™ or OPC client that can also coexist with FactorySuite ™ 2000 and greater. Communication Protocols The OMRON Ethernet Direct DA...
Page 6 - FINS Message Communication; Accessing Items via the DAServer
Klinkmann Automation Omron Ethernet DAServer 4 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 FastDDE FastDDE provides a means of packing many proprietary Wonderware Dynamic Data Exchange messages into a single Microsoft DDE message. This packing improves efficiency and performance by ...
Page 8 - Features
Klinkmann Automation Omron Ethernet DAServer 6 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 • topic name: Meaningful names are configured in the DAServer to identify specific devices. These names are then used as the topic names in all conversations with that device. For example, Omr...
Page 9 - CHAPTER 2; Before starting the OMRON Ethernet DAServer
Klinkmann Automation Omron Ethernet DAServer 7 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 CHAPTER 2 Before starting the OMRON Ethernet DAServer This chapter contains instructions how to configure OMRON PLCs to be accessible by Omron Ethernet DAServer in OMRON Ethernet FA network. C...
Page 15 - Example program for sending “unsolicited” data from PLC
Klinkmann Automation Omron Ethernet DAServer 13 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 To complete the configuration: from the "Ethernet Unit CPU Bus Unit" (or from the "PLC IO Table - NewPLC1") dialog box select "Options" and click "Transfer to PLC&...
Page 18 - CHAPTER 3; Configuration; Getting Started Quickly with the DAServer
Klinkmann Automation Omron Ethernet DAServer 16 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 CHAPTER 3 Configuration Once the KLINKMANN Omron Ethernet DAServer has been installed, a small amount of configuration is required. This configuration is performed using the DAServer Manager ...
Page 19 - Configuring the DAServer
Klinkmann Automation Omron Ethernet DAServer 17 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 4. From the System Management Console, find the Omron Ethernet DAServer in the DAServer Manager tree, the location in which it is installed. • Under the Local branch node, the name of the DAS...
Page 22 - DASOmronEth Hierarchy in the DAServer Manager
Klinkmann Automation Omron Ethernet DAServer 20 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 • To activate the DAServer, right-click on ArchestrA.DASOmronEth.1 and select Activate Server from the shortcut menu. Note: To run the Omron Ethernet DAServer as a service, right-click on the...
Page 27 - Configuring Device Group Definitions
Klinkmann Automation Omron Ethernet DAServer 25 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 Note: Default Watchdog state is “non-active”, i.e. Watchdog Time Interval is equal to zero. Note: In order to use the DAServer, you must activate it. See the DAServer Manager documentation fo...
Page 31 - Configuring Device Item Definitions
Klinkmann Automation Omron Ethernet DAServer 29 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 3. In the Archive Configuration Set configuration view, provide a Configuration Set Name. 4. Click Archive. • All current configuration values are saved to the archived set. Once you have arc...
Page 33 - Hot Configuration
Klinkmann Automation Omron Ethernet DAServer 31 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 1. Right-click anywhere in the Device Items dialog box. 2. Select the Clear All command from the shortcut menu. • All the device items listed in the dialog box, including their corresponding ...
Page 34 - CHAPTER 4; Item Names; Item Name General Format
Klinkmann Automation Omron Ethernet DAServer 32 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 CHAPTER 4 Item Names The Omron Ethernet DAServer supports item/point names consistent with the point naming conventions used by OMRON PLCs and programming software. The Server supports almost...
Page 45 - CQM1 PLCs
Klinkmann Automation Omron Ethernet DAServer 43 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 CQM1 PLCs The following table lists the supported item names for the CQM1 PLCs: Memory Area Prefix Tag Type Range Value Range Format Suffix IR & SR area (Bit status) IR Discrete IR0:00......
Page 46 - DAServer Standard System Items
Klinkmann Automation Omron Ethernet DAServer 44 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 102 - IR Output area (Word contents), word address 102 LR62.10 - LR area (Bit status), word address 62, bit number 10 DM21 - DM area (Word contents), word address 21 DAServer Standard System ...
Page 47 - DAServer Global System Item
Klinkmann Automation Omron Ethernet DAServer 45 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 DAServer Global System Item The following system item refers to specific information regarding a global condition of the DAServer. System Item Name Type/ Access Rights Description Values $SYS...
Page 49 - DAServer Device-Group-Specific System Items
Klinkmann Automation Omron Ethernet DAServer 47 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 DAServer Device-Group-Specific System Items The following system items refer to specific information regarding device groups that have been configured in the DAServer. System Item Name Type/ ...
Page 51 - Generic OPC Syntax
Klinkmann Automation Omron Ethernet DAServer 49 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 device groups with a zero update interval (manual protocol triggering). Generic OPC Syntax DAServer serves as a container for the OPC Groups, which provide the mechanism for containing and lo...
Page 52 - CHAPTER 5; Troubleshooting; Monitoring Connectivity Status with the PLC
Klinkmann Automation Omron Ethernet DAServer 50 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 CHAPTER 5 Troubleshooting This chapter describes the troubleshooting tools you can use to deal with the Omron Ethernet DAServer problems you may encounter. The DAServer Manager provides acces...
Page 53 - Monitoring the Status of DAS Conversations; Using DDEStatus and IOStatus in Excel
Klinkmann Automation Omron Ethernet DAServer 51 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 YourOPCAccessPath is the assembly of hierarchy node names leading to a specific controller device. $SYS$Status is the discrete item used to monitor the status of connectivity with the control...
Page 54 - Writing Values to the DAServer from Excel
Klinkmann Automation Omron Ethernet DAServer 52 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 In this example, each time the value of <tagname> changes in the PLC, the DAServer will automatically send the new value to the cell containing the formula in Excel. Note: Refer to the ...
Page 55 - Error Messages and Codes; DAServer Error Messages
Klinkmann Automation Omron Ethernet DAServer 53 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 Error Messages and Codes Generic DAServer error messages and Omron Ethernet-DAServer-specific messages are supported. Use the Log Flag data to customize the messages logged to the Log Viewer....
Page 59 - Server-Specific Error Codes; FINS Response Codes
Klinkmann Automation Omron Ethernet DAServer 57 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 Server-Specific Error Codes There are following server-specific error codes, shown in the table, that augment those provided by the DAS Toolkit. Error code Logger Message Log Flag -10002 PLC ...
Page 64 - CHAPTER 6; Reference; DAServer Architecture; DAServers
Klinkmann Automation Omron Ethernet DAServer 62 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 CHAPTER 6 Reference Contents • DAServer Architecture • Component Environments DAServer Architecture Note: DAServers are supported on Microsoft Windows 2000 and Windows XP only. NetDDE protoco...
Page 65 - DAS Engine
Klinkmann Automation Omron Ethernet DAServer 63 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 Each physical part of a DAServer is comprised of a set of .exe and/or .dll modules. Wonderware provides the Plug-ins and the DAS Engine. The DAS Toolkit user creates the PLC Protocol Layer (D...
Page 66 - Component Environments
Klinkmann Automation Omron Ethernet DAServer 64 Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3 17014m13 The PLC Protocol Layer provides a protocol-translation function for specific hardware, such as OMRON FinsGateway; and it serves as an interface between the DAS Engine and the hardware. Compon...