  • Page 2 – CYLINDER PROGRAMMING; Figure 3 Wiring to an Inductive Ignition System.; MOUNTING; then install the screws.; WIRING; Red; Connects to a switched 12 volt source.; Black; On inductive ignitions, it connects to the coil negative terminal.; Figure 2 Cylinder Select Loops.; CYLINDERS CUT LOOPS; NONE
  • Page 3 – Figure 4 Wiring to an MSD Ignition Control.
  • Page 4 – Limited Warranty; or consequential damages.; Service; When returning MSD components for warranty service,; Proof of Purchase must be supplied for verification. After; All returns must have a Return Material Authorization (RMA) number; issued to them before; M S D; Module Selectors: These Selectors offer; 2 different rpm limits at the turn of a knob.; RPM PART NUMBER
Loading the manual

IMPORTANT: Read the instructions before attempting the installation.

Parts Included

1 - RPM Window Switch

4 - Self Tapping Screws

Note: RPM Modules must be purchased separately. See the chart on the last page for part

numbers.

The RPM Activated Window Switch can be connected to stock ignition systems or MSD Ignitions. When

using a capacitive discharge ignition such as an MSD,

do not connect the Switch to the coil negative

terminal. Damage to the Switch may occur.
The Switch is capable of carrying 1.5 amps. If the circuit you are activating requires more current, an

MSD Relay, PN 8960 or 8961 must be used. The MSD RPM Activated Switch is equipped with a "smart

driver". This circuit will protect the RPM Switch from damage by monitoring its temperature. If there is an

inadvertant short or too much current is drawn through the Switch, the smart driver will sense the increased

temperature and shut the Switch off. However, once the temperature drops to a safe point, the smart driver

will turn the Switch back on. It will continuously cycle On and Off as the temperature dictates.
If you experience a problem with your Switch not operating, turn the circuit off for a few minutes to cool, then try

again. If the circuit activates then shuts off, there may be too much current flow. Check the device's Installation

Instructions to find its recommended maximum current.

The RPM Window Switch has a circuit that activates a device by providing a ground path at a desired

rpm (Figure 1). The ground will be removed at a different rpm to deactivate the device. If no rpm

module is installed, the device will remain activated as long as the rpm is above the activation amount.

Figure 1 Operation of the RPM Window Switch.

4 - Heat-Shrink Caps

M S D  

•   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

ONLINE PRODUCT REGISTRATION: Register your MSD product online and you’ll be entered

in our monthly 8.5mm Super Conductor Spark Plug Wire give-away! Registering your product

will help if there is ever a warranty issue with your product and helps the MSD R&D team create

new products that you ask for! Go to www.msdperformance.com/registration.

MSD RPM Activated Window Switch

PN 8956

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CYLINDER PROGRAMMING; Figure 3 Wiring to an Inductive Ignition System.; MOUNTING; then install the screws.; WIRING; Red; Connects to a switched 12 volt source.; Black; On inductive ignitions, it connects to the coil negative terminal.; Figure 2 Cylinder Select Loops.; CYLINDERS CUT LOOPS; NONE

2 INSTALLATION INSTRUCTIONS M S D   •   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4 CYLINDER PROGRAMMING The Window Switch is programmed for 8-cylinder applications, however it can be used with 4 or 6-cylinder applications. ...

Page 3 - Figure 4 Wiring to an MSD Ignition Control.

INSTALLATION INSTRUCTIONS 3 M S D   •   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4 Figure 4 Wiring to an MSD Ignition Control. Figure 5 Wiring with an MSD Relay. Note: Capacitive discharge ignitions only.

Page 4 - Limited Warranty; or consequential damages.; Service; When returning MSD components for warranty service,; Proof of Purchase must be supplied for verification. After; All returns must have a Return Material Authorization (RMA) number; issued to them before; M S D; Module Selectors: These Selectors offer; 2 different rpm limits at the turn of a knob.; RPM PART NUMBER

RPM Module Kits are supplied with five modules in a range of 200 rpm increments. There are even number sets and odd number sets available. Example: PN 8746 includes 5,000, 5,200, 5,400, 5,600, 5,800 modules. Kit Even Set Odd Set 3,000 Kit PN 8743 87431 4,000 Kit PN 8744 87441 5,000 Kit PN 8745 87451...

Other Msd Models

All Msd Other