  • Page 2 – CHOOSING AN ADVANCE CURVE; FACTOR; Figure 1 Ignition Timing Factors.; TIPS ON SELECTING AN ADVANCE CURVE
  • Page 3 – CENTRIFUGAL ADVANCE CURVE; SELECTING THE ADVANCE SPRINGS; Figure 2 The Factory Equipped Curve.; Timing Curve From Factory; Figure 4 Advance Curves.; SPRING COMBINATION
  • Page 4 – Figure 5 Advance Stop Bushing Chart.; BUSHING SIZE; Silver
  • Page 5 – OPTIONAL VACUUM ADVANCE LOCKOUT; Note: If no shims were required, use one beneath; Figure 10 Checking Installation of the Lockout Plate.
  • Page 6 – Figure 11 Marking the Rotor Location.; INSTALLING THE DISTRIBUTOR; Place the distributor cap back on and
  • Page 7 – Figure 13 Connecting an MSD Ignition Control.
  • Page 8 – to connect to the tach with another tee-splice coming off to use for; Figure 14 Setting the Rev Limiter.; Limited Warranty; or consequential damages.; Service; When returning MSD components for warranty service,; Proof of Purchase must be supplied for verification. After; All returns must have a Return Material Authorization (RMA) number; issued to them before; M S D
Loading the manual

MSD Pro-Billet Small Diameter

Ready-to-Run Ford V8 Distributor

PN 8350; 351C-460, PN 8354; 351W

PN 8352; 289/302

ONLINE PRODUCT REGISTRATION: Register your MSD product online and you’ll be entered

in our monthly 8.5mm Super Conductor Spark Plug Wire give-away! Registering your product

will help if there is ever a warranty issue with your product and helps the MSD R&D team create

new products that you ask for! Go to www.msdperformance.com/registration.

Important:

  Read these instructions before attempting the installation.

Parts Included:

1 - Pro-Billet Distributor

1 - Rotor, PN 8467

1 - Distributor Cap, PN 8431

1 - Advance Kit

Note: The terminals of the Ready-to-Run Ford Distributors require spark plug style terminals. You may 

need to change the terminals and boots of your wires. MSD offers two kits, PN 8849 or PN 8848 that 

are supplied with nine boots and terminals.

TIMING FUNCTIONS

Before continuing with the installation, here are a few definitions you should be aware of:

Initial Timing:    This  is  the  base  timing  (also  referred  to  as  idle  timing)  of  the  engine  before  the 

centrifugal advance begins.

Centrifugal Advance:  The centrifugal (or mechanical) advance mechanism is made up of weights, 

springs, advance cams, and an advance stop bushing.  The amount and rate of advance that your 

distributor  is  capable  of  is  determined  by  the  centrifugal  timing.    If  you  ever  wish  to  lock  out  the 

centrifugal advance, refer to the centrifugal advance section. 

Total Timing:  This is the total of the initial timing plus the centrifugal advance added together.  Example:  

10°  Initial + 25° centrifugal  =  35°  Total Timing. (When checking Total timing, disconnect and cap 

the vacuum canister and plug the vacuum line.)

Vacuum Advance: The  vacuum  advance  will  advance  the  timing  up  to  10°  during  partial  throttle 

driving (with 15 lbs of vacuum). The vacuum line should be routed to a ported vacuum outlet above 

the throttle plates.

Note: MSD Distributors are supplied with the heavy (slow) advance springs and the 21° stop bushing 

installed. This is to prevent detonation in certain applications. Review the information on pages 

2-3 to determine the best advance curve for your application.

RPM LIMIT AND TACHOMETER INFORMATION

Tach Signal:  The Ready-to-Run Distributor features a Gray Tach Output wire which provides a clean signal 

for most tachometers and even some aftermarket fuel injection systems. The signal output 

is a 12 volt square wave, 20° duty cycle.  This wire is also responsible for programming the 

built-in rev limiter. 

1 - O-ring Seal

1 - Vacuum Advance Lock-Out Kit

1 - Tube of Gear Lubricant

1 - Wiring Harness

1 - Gray Tach Jumper

M S D  

•   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CHOOSING AN ADVANCE CURVE; FACTOR; Figure 1 Ignition Timing Factors.; TIPS ON SELECTING AN ADVANCE CURVE

2 INSTALLATION INSTRUCTIONS M S D   •   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4 Rev Limiter: The Ready-to-Run Distributor has a built-in rev limit that can easily be adjusted from 2,000  rpm to over 10,000 rpm. The defau...

Page 3 - CENTRIFUGAL ADVANCE CURVE; SELECTING THE ADVANCE SPRINGS; Figure 2 The Factory Equipped Curve.; Timing Curve From Factory; Figure 4 Advance Curves.; SPRING COMBINATION

INSTALLATION INSTRUCTIONS 3 M S D   •   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4 CENTRIFUGAL ADVANCE CURVE SELECTING THE ADVANCE SPRINGS Figure 2 The Factory Equipped Curve. Timing Curve From Factory Figure 4 Advance Curv...

Page 4 - Figure 5 Advance Stop Bushing Chart.; BUSHING SIZE; Silver

4 INSTALLATION INSTRUCTIONS M S D   •   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4 Figure 5 Advance Stop Bushing Chart. Figure 6 Changing the Advance Stop Bushing. Figure 7 Removing the Retaining Sleeve. SELECTING THE ADVAN...

Other Msd Models

All Msd Other