- Page 2 – Figure 1 Operation of the RPM Activated Swtich.; WIRING; Red; Connects to a switched 12 volt source.; Black Connects to ground.; On inductive ignitions, it connects to the coil negative terminal.; MOUNTING
- Page 3 – Figure 3 Wiring to an MSD Ignition Control.; PN 89501 - MSD Unit must be used on single
- Page 4 – Limited Warranty; or consequential damages.; Service; When returning MSD components for warranty service,; Proof of Purchase must be supplied for verification. After; All returns must have a Return Material Authorization (RMA) number; issued to them before; M S D
Parts Included In This Kit:
1 - RPM Switch
4 - Self Tapping Screws
MSD RPM Activated Switch
PN 89501 - 1-Cylinder, 4 Stroke 720°
PN 89502 - 2-Cylinder, 4 Stroke 360°
1-Cylinder, 2 Stroke 360°
4 - Heat Shrink Caps
Important: Read the instructions before attempting the installation.
Note: RPM Modules must be purchased separately. See the chart on page 4 for part numbers.
PN 89501, 1-CYLINDER, 4-STROKE (720°) ENGINES
This RPM Switch is preset for an ignition trigger, that fires every 720° of crankshaft rotation. This
particular Switch may not be programmed for any other configurations. This unit is typically used on
a multiple cylinder engine, which has a Coil-per-Cylinder ignition system.
PN 89502, 2-CYLINDER, 4-STROKE (360°) ENGINES OR 1-CYL, 2-STROKE (360°)
This RPM Switch is preset for an ignition trigger that fires every 360° of crankshaft rotation. This
particular Switch may not be programmed for any other configuration. This unit is typically used on
a waste spark ignition system equipped with a dual tower coil that fires two cylinders. This coil is
triggered every 360° of crankshaft rotation. This RPM Switch may also be used on a single cylinder,
2-Stroke engine.
Note: If an MSD Ignition is used in conjunction with an RPM Switch an alternate RPM Switch may
be needed.
The RPM Activated Switch can be connected to stock ignition systems or an MSD Ignition. When
using a capacitive discharge ignition such as an MSD, do not connect the Switch to the coil negative
terminal. Damage to the Switch will occur.
The Switch is capable of carrying 1.5 amps of current. If the circuit you are activating requires more
current, an MSD Relay, PN 8960 or PN 8961 must be used. The MSD RPM Activated Switch is
equipped with a “smart driver”. This circuit will protect the RPM Switch from damage by monitoring
its temperature. If there is an inadvertent short or too much current is drawn through the Switch,
the smart driver will sense the increase in temperature and shut the Switch off. However, once the
temperature drops to a safe point, the smart driver will turn the Switch back on. It will continuously
cycle On and Off as the temperature dictates.
If you experience a problem with your Switch not operating, turn the circuit off for a few minutes to
cool then try again. If the circuit activates then shuts off, there may be too much current flow. Check
the device's Installation Instructions to find its recommended maximum current.
The RPM Switch has two activation wires. The Yellow wire is Normally Open and will activate a circuit
by switching to ground. The Gray wire is Normally Closed to ground and will open the ground circuit
at the desired RPM (Figure 1). If no RPM module is installed, the Switch will not activate the circuit.
M S D
• W W W . M S D P E R F O R M A N C E . C O M • ( 9 1 5 ) 8 5 7 - 5 2 0 0 • F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4
ONLINE PRODUCT REGISTRATION: Register your MSD product online and you’ll be entered
in our monthly 8.5mm Super Conductor Spark Plug Wire give-away! Registering your product
will help if there is ever a warranty issue with your product and helps the MSD R&D team create
new products that you ask for! Go to www.msdperformance.com/registration.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 INSTALLATION INSTRUCTIONS M S D • W W W . M S D P E R F O R M A N C E . C O M • ( 9 1 5 ) 8 5 7 - 5 2 0 0 • F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4 Figure 1 Operation of the RPM Activated Swtich. WIRING Red Connects to a switched 12 volt source. Black Connects to ground. White The rpm in...
INSTALLATION INSTRUCTIONS 3 M S D • W W W . M S D P E R F O R M A N C E . C O M • ( 9 1 5 ) 8 5 7 - 5 2 0 0 • F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4 Figure 3 Wiring to an MSD Ignition Control. Figure 4 Wiring a PN 89502 to an inductive ignition. PN 89501 - MSD Unit must be used on single ...
RPM PART NUMBER 3,000 - 5,200 PN 8670 4,600 - 6,800 PN 8671 6,000 - 8,200 PN 8672 7,600 - 9,800 PN 8673 9,000 - 11,200 PN 8674 R P M M o d u l e K i t s a r e s u p p l i e d with five modules in a range of 200 rpm increments. There are even n u m b e r s e t s a n d o d d n u m b e r sets available...