Msd 8731 2-Step Ford 5.0L Mod Motor 2011 Installation- User Manual

Msd 8731 2-Step Ford 5.0L Mod Motor 2011 Installation

Msd 8731 2-Step Ford 5.0L Mod Motor 2011 Installation– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – Figure 2 Wiring the 2-Step Launch Control.; WIRING; Red; 2 volt Connection through this single Red wire.; Black; Connects to a good engine round or the negative battery terminal.; Blue; Activation Wire. When grounded, the launch feature will be active.
  • Page 3 – CONNECT THE ACTIVATION WIRE; The launch rpm limit can be activated through a ground or a 12 volt; Ground: Switch the Blue wire to ground to activate the launch limit.; and schematic. Also, check any wiring for voltage or ground with the; DETAILED IN STEP 5, FOLLOW THIS; OR; Figure 3 Alternate Wiring.
  • Page 4 – Limited Warranty; for special or consequential damages.; Service; When returning MSD components for warranty service,; Proof of Purchase must be supplied for verification. After; All returns must have a Return Material Authorization (RMA) number; issued to them before; M S D I G N I T I O N; CONFIRM INSTALLATION; If the engine has trouble starting or running. check the following:
Loading the manual

M S D I G N I T I O N

• W W W . M S D I G N I T I O N . C O M • ( 9 1 5 ) 8 5 7 - 5 2 0 0 • F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4

MSD 2-Step Launch Control

for Ford 5.0L Mod Motors 2011

PN 8731

ONLINE PRODUCT REGISTRATION: Register your MSD product online and you’ll be entered

in our monthly 8.5mm Super Conductor Spark Plug Wire give-away! Registering your product

will help if there is ever a warranty issue with your product and helps the MSD R&D team create

new products that you ask for! Go to www.msdignition.com/registration.

P a r t s I n c l u d e d :

1 - 2-Step Launch Control

1 - Harness

The 2-Step Launch Control is a low rpm limiter only. The factory speed limiter will not be affected.

This MSD 2-Step Launch Control is designed for Ford Modular 5.0L engines with Coil-on-Plug ignitions. The

2-Step Control switches to a lower rpm limit that will assist in consistent launches and 60-foot times. RPM

adjustments are made via two rotary switches located on the harness side of the unit. The adjustment range

is from 1,000 - 10,900 rpm, in 100 rpm increments. An LED will illuminate when the launch rev limit is active.

Note: It is recommended to have the Service Manual for your vehicle. If you cannot identify an

activation wire, a microswitch or relay may be required.

Note: The engine rpm must drop more than one third of the set launch limit in order to activate. For

example, if the launch limit is set at 3,000 rpm, the engine speed must drop below 2,000 rpm

in order for the launch limit to become active (one third of 3,000 rpm is a 1,000 rpm drop).

Caution: Keeping the engine on a lower rpm limit may cause the Check Engine light to come on

and could potentially damage the catalytic converter.

IMPORTANT: Due to wiring variations on different models, MSD cannot identify specific wiring on

the clutch switches. Consult your Service Manual for wiring schematics.

MOUNTING

The 2-Step Control can be mounted in any

position but keep in mind to mount it so the

rotary dials are accessible for adjustments

(Figure 1). Hardware is supplied for mounting.

Before mounting the unit, confirm that the

wiring harnesses reach their connections.

Parts Bag:

1 - Tap

3 - Mounting Screws

Figure 1 Accessible Rotary Dials.

ROTARY

DIALS

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Figure 2 Wiring the 2-Step Launch Control.; WIRING; Red; 2 volt Connection through this single Red wire.; Black; Connects to a good engine round or the negative battery terminal.; Blue; Activation Wire. When grounded, the launch feature will be active.

2 INSTALLATION INSTRUCTIONS M S D I G N I T I O N • W W W . M S D I G N I T I O N . C O M • ( 9 1 5 ) 8 5 7 - 5 2 0 0 • F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4 1. Connect the 3-pin harness to the 2-step and connect the Black wire to the good engine or chassis ground. 2. Disconnect the 2-pin connectors from ...

Page 3 - CONNECT THE ACTIVATION WIRE; The launch rpm limit can be activated through a ground or a 12 volt; Ground: Switch the Blue wire to ground to activate the launch limit.; and schematic. Also, check any wiring for voltage or ground with the; DETAILED IN STEP 5, FOLLOW THIS; OR; Figure 3 Alternate Wiring.

INSTALLATION INSTRUCTIONS 3 M S D I G N I T I O N • W W W . M S D I G N I T I O N . C O M • ( 9 1 5 ) 8 5 7 - 5 2 0 0 • F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4 CONNECT THE ACTIVATION WIRE The launch rpm limit can be activated through a ground or a 12 volt source. Ground: Switch the Blue wire to ground to ac...

Page 4 - Limited Warranty; for special or consequential damages.; Service; When returning MSD components for warranty service,; Proof of Purchase must be supplied for verification. After; All returns must have a Return Material Authorization (RMA) number; issued to them before; M S D I G N I T I O N; CONFIRM INSTALLATION; If the engine has trouble starting or running. check the following:

Limited Warranty M SD IGNITION warrants this product to be free from defects in material and workmanship under its intended normal use*, when properly installed and purchased from an authorized MSD dealer, for a period of one year from the date of the original purchase. This warranty is void for any...

Other Msd Models