Mr. Heater HS4040SPLP - User Manual

Mr. Heater HS4040SPLP

Mr. Heater HS4040SPLP Heater – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 2 – CONTENTS; Connection diagram for flame rod current; Carbon Monoxide Poisoning:; THE STATE OF C ALIFORNIA REQUIRES THE; LANGUAGES; ENGLISH
  • Page 3 – GENERAL INFORMATION; USE MODERATE AMOUNT OF PIPE DOPE; Figure 1. Pipe Compound Application
  • Page 4 – Figure 3. Typical Piping Installation; FIGURE 1; When­a­higher­than­the­maximum­recommended­
  • Page 5 – must be electrically grounded in accordance with the; CLEANING INFORMATION
  • Page 6 – OPERATOR MAINTENANCE; operation or maintenance of your heater.; ADJUSTING THE PILOT FL AME; increase pilot flame.; REPL ACING THE GAS VALVE UNIT; Intermittent Use; THERMOSTAT
  • Page 7 – TABLE 4. TROUBLESHOOTING CHART; SYMPTOMS; HIGH ALTITUDE OPERATION; altitude rating plate with stamped data, necessary
  • Page 8 – CONNEC TION DIAGRAM FOR FL AME ROD CURRENT; MEANS OF PROVING ADEQUATE GROUNDING AREA; the installation is the measurement of the flame rod; Figure 3; ­–­Using­a­microammeter­to­prove­adequate­grounding­area.
  • Page 10 – Replacement Parts for Retro Grid Kits
  • Page 12 – REPL ACEMENT PARTS LIST FOR CONTROL
  • Page 15 – TYPIC AL BEAM MOUNT; FIGURE 4; HORIZONTAL MOUNT; CLEARANCES TO COMBUSTIBLES; TYPIC AL WALL MOUNT; MOUNTING
  • Page 16 – USE­ONLY­MANUFACTURER’S­REPLACEMENT­PARTS.­USE­; PARTS ORDERING INFORMATION:; or direct from the factory; FOR INFORMATION REGARDING SERVICE; LIMITED WARRANTY; ­reserves­the­right­to­make­changes­at­any­time,­without­notice­or­; OPERATING INSTRUC TIONS AND OWNER’S MANUAL; READ INSTRUC TIONS C AREFULLY:; Read and follow all; HEATSTAR High-Intensity Infrared Heaters
  • Page 17 – GUIDE D’UTILISATION ET MANUEL DU PROPRIÉTAIRE; LISEZ SOIGNEUSEMENT LES INSTRUC TIONS :; ­Lisez­et­suivez­toutes­; Radiateurs infrarouges à forte intensité HEATSTAR; cet appareil ou de tout autre appareil.; ­utiliser­les­interrupteurs­électriques.; NE PAS; service­ou­le­fournisseur­de­gaz.
  • Page 18 – TABLE DES MATIÈRES; Intoxication au monoxyde de carbone :; REMARQUE; LANGUES; ANGLAIS
  • Page 19 – INFORMATIONS GÉNÉRALES; DÉGAGEMENTS Dégagements minimums par rapport aux; ALIMENTATION EN GAZ
  • Page 20 – Figure 3. Installation normale de la tuyauterie
  • Page 21 – SYSTÈME ÉLEC TRIQUE; FIGURE 2
  • Page 22 – DE L’OPÉRATEUR; AJUSTEMENT DE L A FL AMME DE L A VEILLEUSE; PROCÉDURE DE DÉMARRAGE; L A VALVE DE GAZ; FRÉQUENCE DES CONTRÔLES; Utilisation intermittente
  • Page 23 – TABLEAU 4. TABLEAU DE DÉPANNAGE; UTILISATION EN HAUTE ALTITUDE
  • Page 24 – SCHÉMA DE CONNEXION DU COURANT DU DÉTEC TEUR DE FL AMME; TESTER SI L A ZONE DE MISE À L A TERRE EST ADÉQUATE
  • Page 25 – Liste des pièces de rechange pour les radiateurs
  • Page 28 – LISTE DES PIÈCES DE RECHANGE POUR LE SYSTÈME
  • Page 31 – MONTAGE SUR POUTRE NORMAL; MONTAGE HORIZONTAL; DÉGAGEMENTS PAR RAPPORT AUX COMBUSTIBLES; MONTAGE MURAL NORMAL; MONTAGE
  • Page 32 – POUR DES INFORMATIONS SUR LE SERVICE
  • Page 33 – INSTRUCCIONES DE USO Y MANUAL DEL USUARIO; LEA CUIDADOSAMENTE L AS INSTRUCCIONES:; Lea y siga todas; Calentadores infrarrojos de alta intensidad HEATSTAR; Si no se siguen al pie de la letra las instrucciones de este manual,; Abra­las­ventanas
  • Page 34 – CONTENIDOS; Intoxicación con monóxido de carbono:; IDIOMAS; INGLÉS
  • Page 35 – INFORMACIÓN GENERAL
  • Page 36 – Figura 3. Instalación típica de las tuberías; FIGURA 1
  • Page 37 – TERMOSTATO Y UBIC ACIÓN; FIGURA 2
  • Page 38 – RESOLUCIÓN DE PROBLEMAS; PROCEDIMIENTO DE ENCENDIDO; Uso intermitente; TERMOSTATO
  • Page 39 – TABL A 4. CUADRO DE RESOLUCIÓN DE PROBLEMAS; FUNCIONAMIENTO EN ALTITUDES ELEVADAS; SÍNTOMAS
  • Page 40 – DIAGRAMA DE CONEXIÓN DE L A CORRIENTE DE L A VARILL A DE L A LL AMA; MEDIOS PARA DEMOSTRAR UN ÁREA DE CONEXIÓN; Figura 3
  • Page 44 – LISTA DE REPUESTOS PARA EL SUFIJO DEL; LISTA DE REPUESTOS PARA EL SUFIJO DEL SISTEMA
  • Page 47 – MONTAJE TÍPICO PARA VIGAS; FIGURA 4; MONTAJE HORIZONTAL; DISTANCIA A COMBUSTIBLES; MONTAJE TÍPICO PARA PAREDES; MONTAJE
  • Page 48 – USE­SOLAMENTE­REPUESTOS­DEL­FABRICANTE.­EL­; SI DESEA OBTENER INFORMACIÓN ACERC A DE REPARACIONES
Loading the manual

OPERATING INSTRUC TIONS AND OWNER’S MANUAL

READ INSTRUC TIONS C AREFULLY:

Read and follow all

instructions. Place instructions in a safe place for future
reference. Do not allow anyone who has not read these
instructions to assemble, light, adjust or operate the heater.

HEATSTAR High-Intensity Infrared Heaters

LANGUAGES

MODELS

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.

If the information in this manual is not followed exactly, a fire or explosion
may result causing proper ty damage, personal injury or loss of life.

WARNING:

­—­ Do­not­store­or­use­gasoline­or­other­flammable­vapors­and­liquids­in­the­vicinity­of­this­or­any­

other appliance.

—­ WHAT­TO­DO­IF­YOU­SMELL­GAS
­ •­ Open­Windows
­ •­

DO NOT

try to light any appliance.

­ •­

DO NOT

use electrical switches.

­ •­

DO NOT

­use­any­telephone­in­your­house.­Immediately­call­your­local­gas­supplier­from­a

­ ­

neighbor's­telephone.­Follow­the­gas­supplier's­instructions.

­ •­

DO NOT

touch any electrical switch; do not use any phone in your building.

­ •­ Installation­and­service­must­be­perfomed­by­a­qualified­installer,­service­agency­or­the­gas

supplier.

­ •­ If­you­cannot­reach­your­gas­supplier,­call­the­Fire­Department.

This­is­an­unvented­gas-fired­heater.­It­uses­air­(oxygen)­from­the­area­in­which­it­is­used.­Adequate­
combustion­and­ventilation­air­must­be­provided.­Refer­to­page­4­&­5

ENERCO­GROUP­INC.,­4560­W.­160TH­ST.,­CLEVELAND,­OHIO­44135­•­866-447-2194

4000 & 8000 Models

9000 Models

HS4030­ HS8070­

HS9100

HS4040­ HS9080­ HS9120
HS8050­ HS9090­ HS9140
HS8060­ HS9100S­ ­­

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CONTENTS; Connection diagram for flame rod current; Carbon Monoxide Poisoning:; THE STATE OF C ALIFORNIA REQUIRES THE; LANGUAGES; ENGLISH

E2 Enerco Group, Inc. |Gas-Fired Infra-Red Space Heaters Operating Instructions and Owner’s Manual CONTENTS General­Information .......................................................... 3 Clearances ........................................................................ 3 Gas­Supply .................

Page 3 - GENERAL INFORMATION; USE MODERATE AMOUNT OF PIPE DOPE; Figure 1. Pipe Compound Application

E3 Operating Instructions and Owner’s Manual Enerco Group, Inc. | Gas-Fired Infra-Red Space Heaters 1. GENERAL INFORMATION a. Your­heater­comes­fully­assembled­and­is­tested­at­ the factory for proper gas and input as stated on the name plate. b. Before­proceeding­with­the­installation,­be­sure­to­i...

Page 4 - Figure 3. Typical Piping Installation; FIGURE 1; When­a­higher­than­the­maximum­recommended­

E4 Enerco Group, Inc. |Gas-Fired Infra-Red Space Heaters Operating Instructions and Owner’s Manual NOTE: 1.­Only­Use­A­Pipe­Compound­Which­Is­Resistant­To­Liquefied­Gases­On­L.P.­Installations. 2.­Fittings­Shown­Are­Not­Included­With­Heater. Figure 3. Typical Piping Installation Sediment trap FIGURE...

Other Mr. Heater Heaters Models

All Mr. Heater Heaters