Page 2 - WARNINGS; This appliance is equipped for (natural; CONTENTS; SOCIAL MEDIA
2 Installation Instructions and Owner’s Manual Unvented Liquid Propane Fired Room Heater WARNINGS IMPORTANT : Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fi re,...
Page 3 - DANGER; Carbon Monoxide Poisoning:; Figure 1; Fresh Air for Combustion; Operating heater above elevations of 4,500 feet; SPECIFICATIONS
3 Installation Instructions and Owner’s Manual Unvented Liquid Propane Fired Room Heater DANGER : Carbon monoxide poisoning may lead to death. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the fl u, with headaches, dizziness, or nausea. If you have these signs, the hea...
Page 4 - Determine the Type of Heater Location; LOCAL CODES; WARNING; National Fuel Gas
4 Installation Instructions and Owner’s Manual Unvented Liquid Propane Fired Room Heater b. Whether stripping has been added on operable windows and doors, and c. Caulking or sealants are applied to areas such as joints around windows and door frames, between wall-ceiling joints, between wall panels...
Page 5 - INSTALLATION; Figure 2
5 Installation Instructions and Owner’s Manual Unvented Liquid Propane Fired Room Heater include attics* and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts. *IMPORTANT: Do not prov...
Page 6 - CHECK GAS TYPE; Figure 4; FASTENING HEATER TO WALL; Figure 5
6 Installation Instructions and Owner’s Manual Unvented Liquid Propane Fired Room Heater WARNING: A qualifi ed service person must install heater. Follow all local codes. CHECK GAS TYPE Use only LP-gas. If your gas supply is not LP-gas , do not install heater. Call dealer where you bought heater for...
Page 7 - Figure 6
7 Installation Instructions and Owner’s Manual Unvented Liquid Propane Fired Room Heater Figure 6 Attaching to Wall Stud: This way is the best providing the strongest mounting in wood frame houses. Attaching to Wall Anchor: This way allows you to attach mounting bracket to hol-low walls (wall areas ...
Page 8 - FLOOR MOUNTING AWAY FROM WALL:
8 Installation Instructions and Owner’s Manual Unvented Liquid Propane Fired Room Heater Figure 10 2. Mark screws locations on wall. 3. Remove heater from mounting bracket. 4. If installing bottom mounting screw into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attachin...
Page 9 - CHECKING GAS CONNECTIONS
9 Installation Instructions and Owner’s Manual Unvented Liquid Propane Fired Room Heater Figure 12 CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once. WARNING: Never use an open fl ame to check for a gas leak. Appl...
Page 10 - Operating Your Heater; OPERATING YOUR HEATER; FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; LIGHTING INSTRUCTIONS
10 Installation Instructions and Owner’s Manual Unvented Liquid Propane Fired Room Heater 6. Correct all leaks at once. 7. Light heater (see Operating Your Heater , page page 10. 8. Turn off heater (see To Turn OFF Gas to Appliance , page 10. 9. Replace front panel. OPERATING YOUR HEATER FOR YOUR SA...
Page 11 - TO TURN OFF GAS TO APPLIANCE; To Turn OFF Gas to; CLEANING AND MAINTENANCE; CLEANING ODS/PILOT AND BURNER
11 Installation Instructions and Owner’s Manual Unvented Liquid Propane Fired Room Heater TO TURN OFF GAS TO APPLIANCE SHUTTING OFF HEATER: 1. Turn off equipment shutoff valve. 2. Turn control knob clockwise to the OFF position. SHUTTING OFF BURNER ONLY (PILOT STAYS LIT) 1. Turn control knob clockwi...
Page 12 - TROUBLESHOOTING; Only a qualifi ed service person should service and repair heater.
12 Installation Instructions and Owner’s Manual Unvented Liquid Propane Fired Room Heater TROUBLESHOOTING NOTE: All troubleshooting items are listed in order of operation and likely occurrence. WARNING: Only a qualifi ed service person should service and repair heater. CAUTION: Never use a wire need...
Page 14 - PARTS LIST AND DIAGRAM
14 Installation Instructions and Owner’s Manual Unvented Liquid Propane Fired Room Heater MODEL: BF10TB LP / BF10T LP ITEM P/N PART DESCRIPTION QTY ITEM P/N PART DESCRIPTION QTY 1 80040 Wire Guard 1 13 80055 Regulator Mounting Bracket 1 2 80051 Front Panel 1 14 80020 Regulator Connection 1 3 80038 G...
Page 16 - REPLACEMENT PARTS ORDERING INFORMATION:; Accessories may be purchased at any Mr. Heater local dealer or; FOR INFORMATION REGARDING SERVICE; OPERATING INSTRUCTIONS; READ INSTRUCTIONS CAREFULLY:; Read and follow all instructions. Place instructions in a safe
16 Installation Instructions and Owner’s Manual Unvented Liquid Propane Fired Room Heater Mr. Heater, Inc. reserves the right to make changes at any time, without notice or obligation, in colors, specifications, accessories, materials and models. WARNING: USE ONLY MANUFACTURERÊS REPLACEMENT PARTS. U...