Screw (B)

M4 x 16

● The Drain Pump should be installed on the wall next to the left side of the indoor unit for use.

● By installation of the Drain Pump, it is possible to run the drain tube and refrigerant tube together vertically.

● The Drain Pump should be installed after the indoor unit is positioned on the wall.

*

Be sure to carefully read this manual and the installation manual for the indoor unit first before installation of the Drain Pump.

1. Accessories

* The items (B) – (F) are packed between main body and cover of the Drain Pump. Take them out after the cover removed.

Mitsubishi package air conditioner optional equipment

Drain Pump installation manual

WARNING

Denotes a condition or operation which, if handled incorrectly,

may lead to serious injury or death.

CAUTION

Denotes a condition or operation which, if handled incorrectly,

may lead to bodily injury or property damage.

CAUTION

Make sure that the refrigerant pipes are well insu-

lated to prevent dew condensation.

Incomplete insulation may cause dew conden

-

sation on the surface of the pipes, wetting the

ceiling, floor, and other important property.

(A) Drain

Pump

(B) Screw

(C) Drain

tube

(D) Drain tube

cover

(E) Tube clip

(F) Pull tight

(G) Paper

pattern

(H) Wiring

plate

x 1

(M4 x 16) x 1

(M4 x 35) x 6

x 1

x 1

x 1

x 1

x 1

x 1

2. Overall dimensions and required installation space (mm)

● Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED

FOR SAFETY” before installation.

● Be sure to observe the warnings and cautions specified here as they include

important items related to safety.

● Precautions are classified as follows, according to the level of potential danger.

Required space for installation of Drain Pump

[Maintenance space]

3. Before installation of the Drain Pump

3-1 Set up of the Drain Pump

● Remove the cover and the mounting plate which is fixed on the back of the Drain Pump each.

* The packaging material which is put between the cover and the main body of Drain Pump is only for cushion for

transportation. Take it out as it is unnecessary.

* Take out the accessories.

● Run the pull tight (F) attached through the square hole on the mounting plate.

● Cut the knock out hole on the cover with a nipper and etc.

● The installation place should be carefully considered if it is proper

for installation. If it is not strong enough to hole the unit, make it

stronger by using board or beam before installation.

(1) Decide the installation position of the mounting plate by using the

paper pattern (G) attached.

(* The left end of the indoor unit should be marked in advance.)

1) Fix the paper pattern on the wall with the screw (B) (M4 × 16)

attached with putting it to the left end of the indoor unit for

positioning of the Drain Pump as shown in the drawing.

2) Position the mounting plate with pushing it against the paper

pattern.

(2) Fix the mounting plate with the screws (B) (M4 × 35) attached. Fix

the mounting plate using the 5 dia. holes.

(6 locations pointed by arrows in the drawing.)

In case that the mounting plate is fixed by fixing bolts (through

bolts, bolt anchors, or nut anchors), get M10 or W3/8 screws locally

and put them into two ø 12 holes of the mounting plate to fix it.

(3) When the mounting plates is installed, remove the paper pattern.

(4) Check that the mounting plate is level and positioned correctly

with the indoor unit. (Fig. 2)

* The screws removed will be used later. Keep them not to lose.

Cover

Screws (4 pcs)

Mounting plate

Screws (4 pcs)

Main body of

Drain Pump

Pull tight (F)

(1) Make the knock out hole for left side piping on the left side panel of the indoor unit.
(2) Pull out the drain cap from the left

drain outlet.

● Hold the convex section at the

end and pull the drain cap.

(4) Insert the drain cap into the

right drain outlet.

● Insert a screwdriver or similar tool

into the hole at the end of the cap and

insert the cap fully into the outlet.

(3) Remove the drain hose from the

indoor unit.

● Hold the end of the drain hose (a)

(marked by the arrow) and pull the

drain hose out (b).

(5) Insert the accessory drain hose (C)

into the left drain outlet.

Insert the hose up to the base of the

drain pipe connection opening.

*

Make sure that the hook on the drain

hose is securely caught on the projec

-

tion in the opening in the drain pan.

(6) Install the indoor unit.

4. Installation of the Drain Pump

4-1 Fixing of the mounting plate

3-2 Set up and installation of the indoor unit

(* See the item of piping connection set up in the installation manual of the indoor unit.)

Fig. 6

Marking

Mounting plate

Align these 4 sides

with the paper

pattern (G).

Indoor unit

Paper pattern (G)

Fig. 5-2

Fig. 5-4

Fig. 5-1

Drain

cap

Fig. 5-3

Drain

cap

Drain

cap

2

1

RG79Y376H01

Hook

Fig. 4

(* Position the indoor unit first.)

CAUTION

The indoor unit must be installed horizontally.

Otherwise, the water can leak and it will make the wall dirty.

● After installation work has been completed, explain the “ THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR

SAFETY ”, use, and maintenance of the unit to the customer and perform the test run to ensure normal operation.

● Both the installation manual and operation manual must be given to the user for keeping. These manuals must be

passed on to subsequent users.

THE FOLLOWING SHOULD ALWAYS

BE OBSERVED FOR SAFETY

CAUTION

Make sure that the drainage piping is carried out

correctly following the installation manual and that it

is insulated in order to prevent dew condensation.

Any deficiency caused by piping may result in water leakage,

wetting the ceiling, floor, and other personal property.

WARNING

Ask a dealer or an authorized technician to

install the unit.

If the unit is installed incorrectly, water leak

-

age, electric shock, or fire may result.

Model PAC-SH94DM-E

PKA-RP.KAL

PKFY-P.VKM-E

(a)

(b)

Knock out hole

for piping

Flexible drain tube

(VP20) port (female)

Refrigerant pipe

(Two pipes can be

raised together)

Hole for

Indoor

unit

piping

800

(Max.

lift)

500

(Max.

lift)

R 20

79

21

275

300

167

300

Dimension of Mounting plate

Fig. 1

Fig. 3

WARNING

For installation work, follow the instructions

in the installation manual.

If the unit is installed incorrectly, water leak

-

age, electric shock, or fire may result.

78.5

187

(Make sure of the following items attached with the Drain Pump before installation.)

305

55 (Space for piping)

Mounting

plate

Indoor unit

Tube band position

Paper pattern

2 - ø12 dia. hole

(M10 or W3/8)

6 - ø5 dia. hole

(M4 x 35)

30

18

85

120

70

80
30
90

50

Fig. 2

8

* The same space is

required for the left front

and rear piping.

*

In case that there is a rim at the corner of ceiling,
consider the dimension of the rim before installation.

Obstruc

-

tion

300

3

1,170

Drain Pump

250

or

more

100.5 or more

365

108

or

more

550 or more

60 or less

*

5

RG79Y376H01_EN.indd 1