Screw (B)
M4 x 16
● The Drain Pump should be installed on the wall next to the left side of the indoor unit for use.
● By installation of the Drain Pump, it is possible to run the drain tube and refrigerant tube together vertically.
● The Drain Pump should be installed after the indoor unit is positioned on the wall.
*
Be sure to carefully read this manual and the installation manual for the indoor unit first before installation of the Drain Pump.
1. Accessories
* The items (B) – (F) are packed between main body and cover of the Drain Pump. Take them out after the cover removed.
Mitsubishi package air conditioner optional equipment
Drain Pump installation manual
WARNING
Denotes a condition or operation which, if handled incorrectly,
may lead to serious injury or death.
CAUTION
Denotes a condition or operation which, if handled incorrectly,
may lead to bodily injury or property damage.
CAUTION
Make sure that the refrigerant pipes are well insu-
lated to prevent dew condensation.
Incomplete insulation may cause dew conden
-
sation on the surface of the pipes, wetting the
ceiling, floor, and other important property.
(A) Drain
Pump
(B) Screw
(C) Drain
tube
(D) Drain tube
cover
(E) Tube clip
(F) Pull tight
(G) Paper
pattern
(H) Wiring
plate
x 1
(M4 x 16) x 1
(M4 x 35) x 6
x 1
x 1
x 1
x 1
x 1
x 1
2. Overall dimensions and required installation space (mm)
● Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED
FOR SAFETY” before installation.
● Be sure to observe the warnings and cautions specified here as they include
important items related to safety.
● Precautions are classified as follows, according to the level of potential danger.
Required space for installation of Drain Pump
[Maintenance space]
3. Before installation of the Drain Pump
3-1 Set up of the Drain Pump
● Remove the cover and the mounting plate which is fixed on the back of the Drain Pump each.
* The packaging material which is put between the cover and the main body of Drain Pump is only for cushion for
transportation. Take it out as it is unnecessary.
* Take out the accessories.
● Run the pull tight (F) attached through the square hole on the mounting plate.
● Cut the knock out hole on the cover with a nipper and etc.
● The installation place should be carefully considered if it is proper
for installation. If it is not strong enough to hole the unit, make it
stronger by using board or beam before installation.
(1) Decide the installation position of the mounting plate by using the
paper pattern (G) attached.
(* The left end of the indoor unit should be marked in advance.)
1) Fix the paper pattern on the wall with the screw (B) (M4 × 16)
attached with putting it to the left end of the indoor unit for
positioning of the Drain Pump as shown in the drawing.
2) Position the mounting plate with pushing it against the paper
pattern.
(2) Fix the mounting plate with the screws (B) (M4 × 35) attached. Fix
the mounting plate using the 5 dia. holes.
(6 locations pointed by arrows in the drawing.)
In case that the mounting plate is fixed by fixing bolts (through
bolts, bolt anchors, or nut anchors), get M10 or W3/8 screws locally
and put them into two ø 12 holes of the mounting plate to fix it.
(3) When the mounting plates is installed, remove the paper pattern.
(4) Check that the mounting plate is level and positioned correctly
with the indoor unit. (Fig. 2)
* The screws removed will be used later. Keep them not to lose.
Cover
Screws (4 pcs)
Mounting plate
Screws (4 pcs)
Main body of
Drain Pump
Pull tight (F)
(1) Make the knock out hole for left side piping on the left side panel of the indoor unit.
(2) Pull out the drain cap from the left
drain outlet.
● Hold the convex section at the
end and pull the drain cap.
(4) Insert the drain cap into the
right drain outlet.
● Insert a screwdriver or similar tool
into the hole at the end of the cap and
insert the cap fully into the outlet.
(3) Remove the drain hose from the
indoor unit.
● Hold the end of the drain hose (a)
(marked by the arrow) and pull the
drain hose out (b).
(5) Insert the accessory drain hose (C)
into the left drain outlet.
●
Insert the hose up to the base of the
drain pipe connection opening.
*
Make sure that the hook on the drain
hose is securely caught on the projec
-
tion in the opening in the drain pan.
(6) Install the indoor unit.
4. Installation of the Drain Pump
4-1 Fixing of the mounting plate
3-2 Set up and installation of the indoor unit
(* See the item of piping connection set up in the installation manual of the indoor unit.)
Fig. 6
Marking
Mounting plate
Align these 4 sides
with the paper
pattern (G).
Indoor unit
Paper pattern (G)
Fig. 5-2
Fig. 5-4
Fig. 5-1
Drain
cap
Fig. 5-3
Drain
cap
Drain
cap
2
1
RG79Y376H01
Hook
Fig. 4
(* Position the indoor unit first.)
CAUTION
The indoor unit must be installed horizontally.
Otherwise, the water can leak and it will make the wall dirty.
● After installation work has been completed, explain the “ THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR
SAFETY ”, use, and maintenance of the unit to the customer and perform the test run to ensure normal operation.
● Both the installation manual and operation manual must be given to the user for keeping. These manuals must be
passed on to subsequent users.
THE FOLLOWING SHOULD ALWAYS
BE OBSERVED FOR SAFETY
CAUTION
Make sure that the drainage piping is carried out
correctly following the installation manual and that it
is insulated in order to prevent dew condensation.
Any deficiency caused by piping may result in water leakage,
wetting the ceiling, floor, and other personal property.
WARNING
Ask a dealer or an authorized technician to
install the unit.
If the unit is installed incorrectly, water leak
-
age, electric shock, or fire may result.
Model PAC-SH94DM-E
PKA-RP.KAL
PKFY-P.VKM-E
(a)
(b)
Knock out hole
for piping
Flexible drain tube
(VP20) port (female)
Refrigerant pipe
(Two pipes can be
raised together)
Hole for
Indoor
unit
piping
800
(Max.
lift)
500
(Max.
lift)
R 20
79
21
275
300
167
300
Dimension of Mounting plate
Fig. 1
Fig. 3
WARNING
For installation work, follow the instructions
in the installation manual.
If the unit is installed incorrectly, water leak
-
age, electric shock, or fire may result.
78.5
187
(Make sure of the following items attached with the Drain Pump before installation.)
305
55 (Space for piping)
Mounting
plate
Indoor unit
Tube band position
Paper pattern
2 - ø12 dia. hole
(M10 or W3/8)
6 - ø5 dia. hole
(M4 x 35)
30
18
85
120
70
80
30
90
50
Fig. 2
8
* The same space is
required for the left front
and rear piping.
*
In case that there is a rim at the corner of ceiling,
consider the dimension of the rim before installation.
Obstruc
-
tion
300
3
1,170
Drain Pump
250
or
more
100.5 or more
365
108
or
more
550 or more
60 or less
*
5