Page 2 - File: Induction Heating; CE And Non CE Models
ProHeat 35 Processes Description Induction Heating Power Source Induction Heating OM-222 166N 2009−03 File: Induction Heating Visit our website at www.MillerWelds.com CE And Non CE Models
Page 3 - From Miller to You
Miller Electric manufactures a full lineof welders and welding related equipment.For information on other quality Millerproducts, contact your local Miller distributor to receive the latest fullline catalog or individual specification sheets. To locate your nearestdistributor or service agency call ...
Page 4 - TABLE OF CONTENTS
TABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 6 - DECLARATION OF CONFORMITY; for European Community (CE marked) products.; declares that; David A. Werba; Date of Declaration
243165 DECLARATION OF CONFORMITY for European Community (CE marked) products. MILLER Electric Mfg. Co., 1635 Spencer Street, Appleton, WI 54914 U.S.A. declares that the product(s) identified in this declaration conform to the essential requirements andprovisions of the stated Council Directive(s) an...
Page 8 - SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING; Symbol Usage; Induction Heating Hazards; ELECTRIC SHOCK can kill.; FUMES AND GASES can be hazardous.
OM-222 166 Page 1 SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING ihom _2007−04 Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, ifnot avoided, will result in death or serious injury. Thepossible hazard...
Page 9 - FIRE OR EXPLOSION hazard.; INDUCTION HEATING can cause burns.; Additional Symbols for Installation, Operation, and Maintenance; FALLING UNIT can cause injury.; MOVING PARTS can cause injury.; California Proposition 65 Warnings
OM-222 166 Page 2 FIRE OR EXPLOSION hazard. D Do not overheat parts. D Watch for fire; keep extinguisher nearby. D Keep flammables away from work area. D Do not locate unit on, over, or near combustible surfaces. D Do not install unit near flammables. D Do not operate where the atmosphere may contai...
Page 11 - Signification des symboles; Dangers relatifs au soudage à l’arc
OM-222 166 Page 4 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION ihom _2007−04fre Se protéger, ainsi que toute autre personne travaillant sur les lieux, contre les étincelles et le métal chaud. 2-1. Signification des symboles DANGER! − Indique une situation dangereuse qui si onl’évite pa...
Page 13 - LIRE LES INSTRUCTIONS.; Proposition californienne 65 Avertissements; Principales normes de sécurité
OM-222 166 Page 6 LE RAYONNEMENT HAUTE FRÉ-QUENCE (HF) risque de provoquerdes interférences. D Le rayonnement haute fréquence (HF) peutprovoquer des interférences avec les équipe-ments de radio-navigation et de communication,les services de sécurité et les ordinateurs. D Demander seulement à des per...
Page 14 - SECTION 3 − DEFINITIONS; Warning Label Definitions
OM-222 166 Page 7 SECTION 3 − DEFINITIONS 3-1. Warning Label Definitions Warning! Watch Out! There arepossible hazards as shown by thesymbols. 1 Electric shock from wiring cankill. 1.1 Wear dry insulating gloves. Do not wear wet or damagedgloves. 1.2 Disconnect input plug or power before working onm...
Page 16 - IP
OM-222 166 Page 9 3-3. WEEE Label (For Products Sold Within The EU) Do not discard product (where ap-plicable) with general waste. Reuse or recycle Waste Electricaland Electronic Equipment (WEEE)by disposing at a designated collec-tion facility. Contact your local recycling officeor your local distr...
Page 17 - SECTION 4 − INSTALLATION; Serial Number and Rating Label Location
OM-222 166 Page 10 SECTION 4 − INSTALLATION 4-1. Serial Number and Rating Label Location The serial number and rating information for the power source is located on the front of the machine. Use the rating labels to determine input power requirements and/or rated output. For future reference, write ...
Page 19 - Connecting 3-Phase Input Power For 460/575 Volt Models
OM-222 166 Page 12 4-6. Connecting 3-Phase Input Power For 460/575 Volt Models 803 994-C 3/8 in Tools Needed: ! Installation must meet all Nationaland Local Codes − have only quali-fied persons make this installation. ! Disconnect and lockout/tagout in-put power before connecting inputconductors fro...
Page 20 - Connecting 3-Phase Input Power For 400/460 Volt IEC And CE Models
OM-222 166 Page 13 Ref. 804 430-A Tools Needed: 4-7. Connecting 3-Phase Input Power For 400/460 Volt IEC And CE Models 3/8 in ! Installation must meet all National andLocal Codes − have only qualified per-sons make this installation. ! Disconnect and lockout/tagout inputpower before connecting input...
Page 21 - Power Source Output Connections
OM-222 166 Page 14 Ref. 803 993-C / Ref. 804 217-A 4-8. Power Source Output Connections 1 Output Connector 1 2 Output Connector 2 3 Protective Plug 4 Air-Cooled Extension Cable 5 Liquid-Cooled Extension Cable The power source is capable of single ordual output. When connected for singlepower output,...
Page 22 - Remote 14 Receptacle RC14 Information and Connections
OM-222 166 Page 15 803 993-C 4-9. Remote 14 Receptacle RC14 Information and Connections 1 Plug 2 Threaded Collar 3 Keyway 4 Remote 14 Receptacle RC14(See Section 4-10) To connect to receptacle, align key-way, insert plug and tightenthreaded collar. A J B K I C L N H D M G E F 3 4 2 1 1 2 4-10. Remot...
Page 23 - -12. Temperature Recorder Socket Information
OM-222 166 Page 16 803 993-C 4-11. Temperature Recorder Receptacle RC9 Information And Connections 1 Plug 2 Threaded Collar 3 Temperature RecorderReceptacle RC9 (See Section4-12) To connect to receptacle, insertplug and tighten threaded collar. 3 2 1 1 2 4-12. Temperature Recorder Socket Information...
Page 25 - -14. 115 Volt AC Duplex Receptacle And Supplementary Protector
OM-222 166 Page 18 803 993-C 4-14. 115 Volt AC Duplex Receptacle And Supplementary Protector 1 115 VAC 2.5 A Single-PhaseAC Receptacle RC1 2 Supplementary Protector CB1(2.5 A) The receptacle supplies nominal 115volts ac auxiliary power for use withthe optional digital recorder. Maxi-mum output from ...
Page 29 - SECTION 5 − COMPONENTS AND CONTROLS; Controls
OM-222 166 Page 22 SECTION 5 − COMPONENTS AND CONTROLS 5-1. Controls . When a control panel button is pushedthe yellow lamp lights to indicate ac-tivation. 1 Power Switch Use switch to turn power source On andOff. 2 TC1−4 Temperature Display Provides temperature display of thermo-couples 1 through 4...
Page 30 - SECTION 6 − SETUP AND OPERATION; Safety Equipment; F SYSTEM SETUP
OM-222 166 Page 23 SECTION 6 − SETUP AND OPERATION 6-1. Safety Equipment Wear the following duringoperation: 1 Dry, Insulating Gloves 2 Safety Glasses With SideShields DO NOT wear rings or watchesduring operation. sb3.1* 1/94 1 2 6-2. System Description The ProHeat 35 Induction Heating Power Source ...
Page 32 - Cannot enter Run mode
OM-222 166 Page 25 6-4. Programming Programming allows the operator to setup a program for a particular heating process. The selections available are Temperature, Remote, Manual, orPower vs Time (Time). 6-4-1. Temperature-Based Control Temperature-based control operates the system and controls the h...
Page 38 - Manual Control; Remote Control; Voltage: 0 V; Power vs Time Control
OM-222 166 Page 31 Mode.......: Custom Program Segment....: 5 Type.......: End Control TC.: 1 Custom Program Screen End segment ends the heat treat cycle. Controller is programmed to control the process using four thermocouples. 6-4-2. Manual Control Manual control allows programming of a specific p...
Page 41 - Cooler; Cooler cannot be turned off; ProHeat
OM-222 166 Page 34 Power....: 0.0 KW TC5: 77 Current..: 0 A TC6: 77 Voltage..: 0 V Frequency: 4.5 KHz Parameters Screen 6-7. Cooler The Cooler button is used to turn the cooler On or Off on systems using liquid-cooled output cables. Systems using liquid-cooled output cables will not deliver output u...
Page 42 - Must be running to enter Hold mode; Hold mode not available when
OM-222 166 Page 35 S The Stop button indicator LED illuminates to indicate no heating cycle is in process. S The temperature displays indicate actual temperature from the TC’s (thermocouples). If no thermocouples are connected, the displays indi- cate OPEN. S Control LEDs illuminate to indicate the ...
Page 44 - System Operating Characteristics; Table 6-1. Power Source Output Characteristics; Air Cooled Output; Liquid Cooled Output
OM-222 166 Page 37 6-9. System Operating Characteristics The power source delivers a high-frequency alternating current output that energizes the coil creating the magnetic field used to heat the workpiece.The power source output characteristics are a function of the configuration, type and number o...
Page 45 - SECTION 7 − MAINTENANCE; Routine Maintenance
OM-222 166 Page 38 SECTION 7 − MAINTENANCE 7-1. Routine Maintenance ! Disconnect power before maintaining. . Maintain more oftenduring severe conditions. n = Check Z = Change ~ = Clean l = Replace * To be done by Factory Authorized Service Agent Reference Every3Months 1 2 1 2 Section 4-8,4-13 l Dama...
Page 47 - Notes
OM-222 166 Page 40 2. Turn ProHeat 35 power switch off. 3. Have qualified person disconnect primary power. 4. Remove precision DVM and TC calibrator. 5. Complete calibration label & place it on unit directly above TC1 display.I.D. No. (TC board serial number) Be sure the serial number matches th...
Page 48 - In
OM-222 166 Page 41 d o e s her e b y c er ti fy th e a b o v e ins tr u m e n t w as c a lib ra te d a ga in s t s tanda rd s and m e e ts o r e x c ee d s al l p u b lis hed s p ec if ic at io ns . T h e a c c ur ac y o f thes e s ta nda rd s is d ir ec tl y tr a c e a b le to th e N at ional In s ...
Page 50 - SECTION 8 − SAFETY PRECAUTIONS FOR SERVICING; Servicing Hazards
OM-222 166 Page 43 SECTION 8 − SAFETY PRECAUTIONS FOR SERVICING Protect yourself and others from injury — read and follow these precautions. 8-1. Symbol Usage OM-222166J - 2007−06, safety_ihtm 2007−04 DANGER! − Indicates a hazardous situation which, ifnot avoided, will result in death or serious inj...
Page 51 - OVERUSE can cause OVERHEATING.; EMF Information
OM-222 166 Page 44 MOVING PARTS can cause injury. D Keep away from moving parts such as fans. D Have only qualified persons remove doors,panels, covers, or guards for maintenance asnecessary. D Keep hands, hair, loose clothing, and tools away from movingparts. D Reinstall doors, panels, covers, or g...
Page 52 - SECTION 9 − DIAGNOSTICS & TROUBLESHOOTING; Operator Interface Indicators
OM-222 166 Page 45 SECTION 9 − DIAGNOSTICS & TROUBLESHOOTING The ProHeat 35 power source has on-board capabilities to aid in troubleshooting problems should any conditions occur during operation. Thistroubleshooting capability consists of the Fault LED, Limit LED, and message screens that appear...
Page 53 - Limit Conditions; Limit Condition Codes
OM-222 166 Page 46 9-2. Limit Conditions A limit condition indicates that the system has encountered an open thermocouple or is outside the range of its optimum operating conditions orparameters. Should a limit condition occur during operation, the yellow Limit LED will flash to indicate a problem. ...
Page 54 - Fault Conditions
OM-222 166 Page 47 Limit Condition Additional Information L11: Coolant Overtemp Limit Check coolant flow and levelClean coolant filters and heat exchangerIncrease number of turnsVerify appropriate insulation thickness L12: Power Source Overtemp Limit Check for blocked ventsClean wind tunnel heat sin...
Page 55 - System Diagnostic Screens
OM-222 166 Page 48 Fault Condition Additional Information F67: Over Frequency Fault Verify heating cable properly wrappedVerify material being heated is magnetic F68: Cable Connection Fault Check for loose/open output connectionVerify all output cables are same typeVerify receptacle plug connected F...
Page 57 - Removing Wrapper and Measuring Input Capacitor Voltage
OM-222 166 Page 50 9-7. Removing Wrapper and Measuring Input Capacitor Voltage ! 900 Volts dc can be presenton the capacitor bus andsignificant DC voltage canremain on capacitors afterunit is Off. Always check thevoltage on inverter assemblyas shown to be sure the inputcapacitors have dischargedbefo...
Page 58 - Blowing Out Inside Of Unit; MATERIAL THICKNESS REFERENCE CHART
OM-222 166 Page 51 9-8. Blowing Out Inside Of Unit ! Turn Off welding powersource and disconnect inputpower. ! Remove wrapper and besure input capacitors aredischarged. Blow out inside of unit. Blow out fanmotors in right side panel and frontpanel. 804 625-B Notes 16 Gauge (.063 in) 22 Gauge (.031 i...
Page 59 - SECTION 10 − ELECTRICAL DIAGRAM
OM-222 166 Page 52 SECTION 10 − ELECTRICAL DIAGRAM Figure 10-1. Circuit Diagram
Page 61 - SECTION 11 − PARTS LIST
OM-222 166 Page 54 SECTION 11 − PARTS LIST . Hardware is common andnot available unless listed. Figure 11-1. Wrappers Ref. 804 218-D 1 3 5 6 7 8 11 9 10 11 See Figure 11-2 See Figure 11-3 4 2 12 13 14 Quantity Description Part No. Dia. Mkgs. Item No. Figure 11-1. Wrappers 1 +217 470 PANEL, side RH 1...
Page 73 - Figure 11-10. Hermaphroditic Blank Plug Assy
OM-222 166 Page 66 . Hardware is common andnot available unless listed. Figure 11-10. Hermaphroditic Blank Plug Assy 804 300-A 1 2 3 4 5 3 4 6 7 8 1 9 Quantity Description Part No. Dia. Mkgs. Item No. Figure 11-10. Hermaphroditic Blank Plug Assy 224 260 1 221 440 O-RING, .737 ID x .103 CS 2 . . . . ...
Page 74 - Figure 11-11. Air−Cooled Output Extension Cables
OM-222 166 Page 67 804 324-A 1 2 3 4 5 6 7 8 Figure 11-11. Air−Cooled Output Extension Cables Description Part No. Dia. Mkgs. Item No. Figure 11-11. Air−Cooled Output Extension Cables 195 404, 195 405, And 300 362 Quantity 1 225 918 SHELL ASSY, connector − air cooled 1 . . . . . . . . . . . . . . . ...
Page 75 - Figure 11-12. Liquid−Cooled Output Extension Cables
OM-222 166 Page 68 1 6 5 7 9 10 8 11 2 3 4 6 5 4 3 804 411-A Figure 11-12. Liquid−Cooled Output Extension Cables Description Part No. Dia. Mkgs. Item No. Figure 11-12. Liquid−Cooled Output Extension Cables (195 402, 195 403, And 300 180) Quantity 1 225 917 Connector Shell 1 . . . . . . . . . . . . ....
Page 77 - Figure 11-14. Quick Connect To Quick Connect Hose; Description
OM-222 166 Page 70 201 432-G 1 Figure 11-14. Quick Connect To Quick Connect Hose Description Part No. Dia. Mkgs. Item No. Figure 11-14. Quick Connect To Quick Connect Hose (204 877) Quantity 1 204955 Ftg, Plstc Coupler Qdisc X 1/4 Npt Female 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 78 - (Equipment with a serial number preface of LK or newer)
Warranty Questions? Call1-800-4-A-MILLERfor your localMiller distributor. miller_warr 2009−01 Your distributor also givesyou ... ServiceYou always get the fast,reliable response youneed. Most replacementparts can be in yourhands in 24 hours. SupportNeed fast answers to thetough welding questions?Con...
Page 79 - Please complete and retain with your personal records.; Contact a DISTRIBUTOR or SERVICE AGENCY near you.; For Service
ORIGINAL INSTRUCTIONS − PRINTED IN USA © 2009 Miller Electric Mfg. Co. 2009−01 Miller Electric Mfg. Co. An Illinois Tool Works Company1635 West Spencer StreetAppleton, WI 54914 USA International Headquarters−USAUSA Phone: 920-735-4505 Auto-AttendedUSA & Canada FAX: 920-735-4134International FAX:...
Page 80 - Head Office; RAPID HEAT
Head Office Rapid Heat SystemsDragon Works Chester RoadSaltney,Chester CH4 8RW T: +44 (0) 1244 670810F: + 44 (0) 1244 680491E: [email protected] www.rapidheatsystems.com RAPID HEAT SYSTEMS