MGE UPS Systems 18/280 kVA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
1
2
3
4
5
6
7
8
9
10
11
12
13
Table of Contents:
Page 2 – CleanWave - Installation and user manual; INDEX
Page 11 – Check that there is no voltage on the terminals.
Loading the manual
T
H
E
U
N
I
N
T
E
R
R
U
P
T
I
B
L
E
P
O
W
E R
P R
O V
I D E
R
Installation and user manual
CleanWave
18÷280 kVA
English
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 - CleanWave - Installation and user manual; INDEX
MGE-UPS CleanWave - Installation and user manual Page 2/13 Version 2.1.4 – 15/01/2007 - INDEX 1. INTRODUCTION .....................................................................................................3 2. PRESENTATION ..........................................................................
Page 3 - ENERAL PRESENTATION
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 3/13 Version 2.1.4 – 15/01/2007 - 1. INTRODUCTION The present document is a user manual for the zero-sequenced filters CleanWave ® . It is intended to the persons responsible for the installation, the use and the maintenance of the filter...
Page 5 - ANGE; According to European standards
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 5/13 Version 2.1.4 – 15/01/2007 - 2.2. R ANGE The following table summarises the characteristics of the different products of the range (at 400V, 50/60Hz). Minimum sections 1 TYPE Power. I phase max I neutral Max Total losses max Phases N...
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 6/13 Version 2.1.4 – 15/01/2007 - 2.3. T ECHNICAL SPECIFICATIONS Standards Construction and safety : IEC-60439-1 Conception : IEC-60289, IEC-60727 IP rating Unprotected : IP00 Protected : IP21 Electrical specifications Frequency : 50 / 60...
Page 7 - no voltage; CCESS TO THE FILTER
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 7/13 Version 2.1.4 – 15/01/2007 - 3. SAFETY CAUTION !!! The CleanWave ® filter exhibits potentially lethal voltages. Like any electrical equipment, the installation and the use of the CleanWave ® require some basic precautions. 3.1. I NTE...
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 8/13 Version 2.1.4 – 15/01/2007 - 4. ELECTRICAL ENGINEERING The electrical study for the implementation of a CleanWave ® filter is very easy. The few instructions described in this document must however be respected in order to ensure the...
Page 9 - INSTALLATION AND STARTING; ANDLING; PE
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 9/13 Version 2.1.4 – 15/01/2007 - 5. INSTALLATION AND STARTING 5.1. H ANDLING The filters are delivered on a wooden tray and can easily be moved with the help of a forklift. They can also be handled with the help of the lifting rings. 5.2...
Page 10 - Table 9; NERGISING
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 10/13 Version 2.1.4 – 15/01/2007 - The connections are the following : Terminal Connection 1 L1 upstream 2 L2 upstream 3 L3 upstream 4 N upstream 5 N downstream 6 L1 downstream 7 L2 downstream 8 L3 downstream Earth Earth (PE) Table 9 The ...
Page 11 - Check that there is no voltage on the terminals.
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 11/13 Version 2.1.4 – 15/01/2007 - 6. MAINTENANCE After installation, the CleanWave ® filter requires almost no maintenance. We only recommend a periodic (e.g. annual) inspection. This inspection must be done with no voltage by a qualifie...