Page 4 - introduction; uses of Pulsar EX20
ii Pulsar EX Rack : 86-153500-00 MGE UPS SYSTEMS introduction In critical situations, count on MGE UPSSYSTEMS Pulsar EX20 Rack and EX30 Rack uninterruptible power supplies (UPS). Their protection keeps your dataintact and accessible.Pulsar EX20 Rack and EX30Rack UPSs ensure top quality power around ...
Page 5 - options
MGE UPS SYSTEMS Pulsar EX Rack : 86-153500-00 iii c Bar graph continuously indicates the battery charge level or the critical load powerlevel; c Pulsar EX20 Rack and EX30Rack are environment friendly: all components arerecyclable and an electronic power-saverdevice reduces power consumption if theUP...
Page 6 - Rack and; Rack; EX-Driver for Windows; personalization of the UPS operating; for networks and
iv Pulsar EX Rack : 86-153500-00 MGE UPS SYSTEMS software supplied withPulsar EX20 Rack and EX30 Rack To meet the different operatingenvironments of your UPS, Pulsar EX Rack includes 2 MGE UPS SYSTEMS softwareprograms: c EX-Driver software for Windows c Network based Solution-Pac TM power management...
Page 7 - general contents; Pulsar presentation
Pulsar EX20 Rack / EX30Rack / EXB20/30 presentation general contents Pulsar presentation ............................................................................................................................. 3 getting started / operation ..........................................................
Page 8 - front view
Pulsar EX Rack : 86-153500-00 7b 5 7a 9 12 11 10 7c 6 13 8 7a Pulsar EX Rack : 86-153500-00 3 MGE UPS SYSTEMS 4 MGE UPS SYSTEMS Pulsar EX20 Rack / EX30Rack front view Pulsar EX20 Rack rear view 1d 1b 1c 1f 1e 1a 2 3 ! … – + – + … … … … % %
Page 11 - key to diagrams; b output receptacles rated each 15A,
MGE UPS SYSTEMS Pulsar EX Rack : 86-153500-00 7 key to diagrams 2 "function" button: switches off audiowarning device or measures loadcharge percentage (if utility powerpresent), 3 "ON/OFF" switch:button pushed in: ONbutton not pushed in: OFF, 5 attached input cord, 6 input circuit b...
Page 12 - technical data; output specifications:; dimensions and weights:
8 Pulsar EX Rack : 86-153500-00 MGE UPS SYSTEMS technical data – + a c output power: v Pulsar EX20 Rack: 2000VA/1400W v Pulsar EX30 Rack: 3000VA/2100W c input voltage: v voltage (V): a 90V to 138V single phase ( 70V to 138V at 1/3 Power, 80V to 138V at 2/3 Power) v frequency (F): 47Hz to 53Hz or 57H...
Page 13 - Rack battery back-up time
MGE UPS SYSTEMS Pulsar EX Rack : 86-153500-00 9 Pulsar EX20 Rack battery back-up time Pulsar EX30 Rack battery back-up time 3000 VA 1500 VA 750 VA t (hours) Pulsar EX30 Rack alone Pulsar EX30 Rack + 1 Pulsar EXB20/30 Pulsar EX30 Rack + 2 Pulsar EXB20/30 0 1 2 3 4 5 2000 VA 1500 VA 1000 VA 500 VA t (...
Page 15 - contents; getting started
MGE UPS SYSTEMS Pulsar EX Rack: 86-153500-00 11 contents getting started .................................................................................................................. 12 location .......................................................................................................
Page 16 - location; connect the AC input cord to the utility
12 Pulsar EX Rack: 86-153500-00 MGE UPS SYSTEMS getting started location c observe the safety rules indicated at the beginning of this document. preliminary checks c check that the "on/off" button " " on the front is not pushed in; c check that rating shown on the rating label corres...
Page 17 - communication; option 1; status information card: after the card is; standard port; option 2; SNMP card: after the card is installed in
MGE UPS SYSTEMS Pulsar EX Rack: 86-153500-00 13 communication c the U-Talk communication port, at the rear of the Pulsar, delivers information in theform of an RS232 series link supported bythe communication protocol exclusive toMGE UPS SYSTEMS.The Solution-Pac TM programs use the data made availabl...
Page 18 - operation; starting up with utility power present; normal operation
14 Pulsar EX Rack: 86-153500-00 MGE UPS SYSTEMS operation starting up with utility power present 17 s 7 s 5 s 0 s several beeps UPS is on utility power 1 s beep output off output off normal operation indicator lights test press button "on/off" : automatic sequence: your load is supportedby t...
Page 19 - starting up with out utility power
MGE UPS SYSTEMS Pulsar EX Rack: 86-153500-00 15 starting up with out utility power 17 s 7 s 5 s 0 s several beeps 1 s beep output off output off normal operation on battery indicator lights test press "on/off" button: automatic sequence: your load is supportedby the battery UPS is on utility...
Page 20 - operation on battery; no utility power; break in utility power
16 Pulsar EX Rack: 86-153500-00 MGE UPS SYSTEMS operation on battery no utility power your load is supplied by the utility power(on line) indicating the loadcharge percentage:here 50% At whatever point the utility powerreturns, Pulsar switches to normaloperation: return of utility power load charge ...
Page 21 - overload; operating anomalies
MGE UPS SYSTEMS Pulsar EX Rack: 86-153500-00 17 overload utility power present 1 beep every second automatic load transfer to bypass operating anomalies device fault v vv v v automatic load transfer to bypass, v vv v v switch off Pulsar (release "on/off" button), disconnect from the wall soc...
Page 23 - proprietary rights statement
Pulsar EX Rack : 86-153500-00 MGE UPS SYSTEMS service and factory repair - call 1 - 800 - 523 - 0142 c direct questions about the operation, repair, or servicing of this equipment to MGE UPS SYSTEMS, Inc. Customer Support Services. Include the part number, and serial number of the unit in any corres...