Page 2 - MGE UPS Systems; IMPORTANT SAFETY INSTRUCTIONS; Read before installing product; Note
Page 2 - 3400723200/AC MGE UPS Systems 1660 Scenic AvenueCosta Mesa, CA 92626(714) 557-1636 For service call1-800-438-7373 www.mgeups.com SAVE THESE INSTRUCTIONS. This manual contains important instructions for 89340-89346 that should be followed during installation and maintenance of the UPS and ba...
Page 3 - Introduction; CAUTION: Safety of persons; CAUTION: Product safety; Special precautions
3400723200/AC - Page 3 Introduction CAUTION: Safety of persons ◗ The UPS has its own internal power source (the battery). Consequently, the power outlets may be energized even if the UPS isdisconnected from the AC-power source. ◗ Dangerous voltage levels are present within the UPS. It should be open...
Page 4 - Foreword; Using this document; Pictograms
Page 4 - 3400723200/AC Foreword Using this document Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. Information may be ...
Page 5 - Contents; Presentation
3400723200/AC - Page 5 Contents 1. Presentation 1.1 Overall view .................................................................................................................................. 7 Tower models ............................................................................................
Page 6 - Maintenance; Technical data
Page 6 - 3400723200/AC Contents 4. Maintenance 4.1 Trouble-shooting ..........................................................................................................................22 4.2 Replacement of the battery module ........................................................................
Page 10 - Unpacking and parts check; Tower models
P U L S A R E v o l u t i o n 1 1 0 0 Page 10 - 3400723200/AC 2. Installation 2.1 Unpacking and parts check RS232 communications cable for Windows Operating Systems. For Unix/Linux Operating Systems, please order for free the following part number: 66090 USB communications cable. CD-ROM with the Sol...
Page 11 - Rack models
P U L S A RE v o l u t i o n 1500 Rack 3400723200/AC - Page 11 2. Installation RS232 communications cable for Windows Operating Systems. For Unix/Linux Operating Systems, please order for free the following part number: 66090 USB communications cable. CD-ROM with the Solution-Pac and UPS Driver soft...
Page 13 - Follow steps 1 to 6 for rack mounting of the UPS on the rails.
P U L S A RE v o l u t i o n 1500 Rack 3400723200/AC - Page 13 2. Installation Follow steps 1 to 6 for rack mounting of the UPS on the rails. The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS. For step 1, screw quantity shown is for 1500 VA. 800 and 1100 VA use two screws...
Page 14 - Follow steps 1 to 3 for rack mounting of the UPS on the rails.; Wall Mount Configuration
P U L S A RE v o l u t i o n 1500 Rack Page 14 - 3400723200/AC 2. Installation 500 Rack model Follow steps 1 to 3 for rack mounting of the UPS on the rails. 1 2 3 3 1 P U L S A R E v o l u t i o n 1500 Rack P U L S A R E v o l u t i o n 1500 Rack Wall Mount Configuration Floor Mount Configuration
Page 15 - Connecting the protected equipment
Pb Hertz 50/60 Hz W/VA 1000W/1440VA Ausg Hertz 50/60 Hz Amps 12A MAX Netz Util Load Mains Reseau Volt 120V~1O Volt 120V~1O 36Vdc, 9Ah U.S. PAT. NO. 6,094,363 Programmable 2 1 Vac OUT I max 12A U.P.S. 34Z5 R Vac IN SITE WIRING FAULT Data line protection T20A/125V~ RS232 344-50254-00 IN OUT 1 - Remove...
Page 16 - Connection to the RS232 or USB communications port
Page 16 - 3400723200/AC Pb Hertz 50/60 Hz W/VA 1000W/1440VA Ausg Hertz 50/60 Hz Amps 12A MAX Netz UtilLoad Mains Reseau Volt 120V~1O Volt 120V~1O 36Vdc, 9Ah U.S. PAT. NO. 6,094,363 Programmable 2 1 Vac OUT I max 12A U.P.S. 34Z5 R Vac IN SITE WIRING FAULT Data line protection T20A/125V~ RS232 344-502...
Page 17 - Installation of the communications-card option
3400723200/AC - Page 17 2. Installation 2.6 Installation of the communications-card option 1 - Remove the slot cover 4 secured by two screws. 2 - Insert the card in the slot. 3 - Secure the card with the two screws. Restricted-access slot forthe communications card 4 Pb Hertz 50/60 Hz W/VA 1000W/144...
Page 18 - Shift to booster or fader mode
The booster and fader functions maintain the output voltage supplied bythe UPS within close tolerances around the rated value even if significantvoltage variations occur in the AC-input power. This avoids calling on bat-tery power.The values defining the voltage range may be set using the UPS Driver...
Page 19 - Operation on battery power; Transfer to battery power; The equipment connected to the UPS is supplied by the battery.; Threshold for the low-battery warning; The equipment is no longer supplied with power.
3400723200/AC - Page 19 1 2 % % 1 2 % % 3. Operation 3.3 Operation on battery power (following failure of AC-input power) Transfer to battery power The AC-input power is out of tolerances, LED 11 goes ON.During operation on battery power, the buzzer beeps every ten seconds. The equipment connected t...
Page 22 - Troubleshooting requiring MGE UPS SYSTEMS after-sales support
Indication LED 12 goes ON andthe buzzer sounds contin-uously. Signification UPS electronics have detected a UPS fault. ◗ The connected equipment is no longer supplied. The equipment connected to the UPS is no longer protected. Correction Call the after-sales support depart-ment. Indication LED 13 fl...
Page 23 - Replacement of the battery module; Removal of the battery module; remove all watches, rings, bracelets and any other metal objects; D - Disconnect the battery module by; Battery Replacement Chart
3400723200/AC - Page 23 P U L S A RE v o l u t i o n 1 1 0 0 B A C 4.2 Replacement of the battery module 4. Maintenance Removal of the battery module When replacing batteries, use the Battery Replacement Chart below to determine the correct battery.This operation may be carried out with the UPS supp...
Page 24 - Installation of the new battery module; CAUTION: risk of electric arc when connecting the battery.
Page 24 - 3400723200/AC 4. Maintenance Installation of the new battery module Carry out the above operation in reverse order. ◗ CAUTION: risk of electric arc when connecting the battery. ◗ To maintain an identical level of performance and safety, use a battery module identical to that previously mou...
Page 25 - A - Unclip the small plate with the MGE
3400723200/AC - Page 25 D A B C P U L S A R Evolution 1500 Rack 4. Maintenance Removal of the battery module This operation may be carried out with the UPS supplying power to the load. A - Unclip the small plate with the MGE logo on the front panel of the UPS. B - Remove the two screws.C - Remove th...
Page 27 - This product has been designed to respect the environment:; UPS recycling at the end of service life:
3400723200/AC - Page 27 5. Environment This product has been designed to respect the environment: It does not contain CFCs or HCFCs. UPS recycling at the end of service life: MGE UPS SYSTEMS undertakes to recycle, by certified companies and in compliance with all applicable regulations, allUPS produ...
Page 28 - Simplified diagram
Page 28 - 3400723200/AC 6. Appendices 6.1 Technical data Simplified diagram Input Output Battery Charger Inverter Booster / fader transformer Filter
Page 29 - Technical characteristics; Output rating
3400723200/AC - Page 29 6. Appendices Technical characteristics (1) The upper and lower thresholds may be set using the UPS Driver software.(2) Or 40 Hz in low-sensitivity mode (may be set using the UPS Driver software).(3) Adjustable from 100 to 127 V using the UPS Driver software. Output rating AC...
Page 30 - Examples of battery backup times
Page 30 - 3400723200/AC 6. Appendices Examples of battery backup times Pulsar Evolution 500 Pulsar Evolution 800 Pulsar Evolution 1100 1 hub 1 router 1 data server + 1 hub + 1 router Pulsar Evolution 1500 2 file/print servers 0 10 20 50 100 t (min) 30 40 60 70 80 90 110 120 0 10 20 50 100 t (min) 30...