Page 2 - CleanWave - Installation and user manual; INDEX
MGE-UPS CleanWave - Installation and user manual Page 2/13 Version 2.1.4 – 15/01/2007 - INDEX 1. INTRODUCTION .....................................................................................................3 2. PRESENTATION ..........................................................................
Page 3 - ENERAL PRESENTATION
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 3/13 Version 2.1.4 – 15/01/2007 - 1. INTRODUCTION The present document is a user manual for the zero-sequenced filters CleanWave ® . It is intended to the persons responsible for the installation, the use and the maintenance of the filter...
Page 5 - ANGE; According to European standards
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 5/13 Version 2.1.4 – 15/01/2007 - 2.2. R ANGE The following table summarises the characteristics of the different products of the range (at 400V, 50/60Hz). Minimum sections 1 TYPE Power. I phase max I neutral Max Total losses max Phases N...
Page 6 - ECHNICAL SPECIFICATIONS; Electrical specifications
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 6/13 Version 2.1.4 – 15/01/2007 - 2.3. T ECHNICAL SPECIFICATIONS Standards Construction and safety : IEC-60439-1 Conception : IEC-60289, IEC-60727 IP rating Unprotected : IP00 Protected : IP21 Electrical specifications Frequency : 50 / 60...
Page 7 - no voltage; CCESS TO THE FILTER
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 7/13 Version 2.1.4 – 15/01/2007 - 3. SAFETY CAUTION !!! The CleanWave ® filter exhibits potentially lethal voltages. Like any electrical equipment, the installation and the use of the CleanWave ® require some basic precautions. 3.1. I NTE...
Page 8 - ELECTRICAL ENGINEERING; LECTRICAL SCHEMATIC; Non; CleanW ave; LECTRICAL PROTECTIONS
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 8/13 Version 2.1.4 – 15/01/2007 - 4. ELECTRICAL ENGINEERING The electrical study for the implementation of a CleanWave ® filter is very easy. The few instructions described in this document must however be respected in order to ensure the...
Page 9 - INSTALLATION AND STARTING; ANDLING; PE
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 9/13 Version 2.1.4 – 15/01/2007 - 5. INSTALLATION AND STARTING 5.1. H ANDLING The filters are delivered on a wooden tray and can easily be moved with the help of a forklift. They can also be handled with the help of the lifting rings. 5.2...
Page 10 - Table 9; NERGISING
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 10/13 Version 2.1.4 – 15/01/2007 - The connections are the following : Terminal Connection 1 L1 upstream 2 L2 upstream 3 L3 upstream 4 N upstream 5 N downstream 6 L1 downstream 7 L2 downstream 8 L3 downstream Earth Earth (PE) Table 9 The ...
Page 11 - Check that there is no voltage on the terminals.
MGE UPS SYSTEMS CleanWave - Installation and user manual Page 11/13 Version 2.1.4 – 15/01/2007 - 6. MAINTENANCE After installation, the CleanWave ® filter requires almost no maintenance. We only recommend a periodic (e.g. annual) inspection. This inspection must be done with no voltage by a qualifie...