Page 2 - Copyright
Copyright © 2007 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. ...
Page 6 - Model Number Designation; xxx; De s c ri p t i o n
2 I NTRODUCTION M ODEL N UMBER D ESIGNATION M ODEL N UMBER D ESIGNATION Figure 1. Model Number Designation B ASE K IT C OMPONENTS AND O PTIONAL A CCESSORIES B AS E K I T P a rt # De s c ri p t i o n MS2122* Stratos E Scanner * See model number designation above for detailed information on interface ...
Page 7 - E P L AC E M E N T
3 I NTRODUCTION B ASE K IT C OMPONENTS AND O PTIONAL A CCESSORIES O P T I O N AL A C C E S S O R I E S P a rt # De s c ri p t i o n AC to DC Power Transformer - Regulated +5V @ 1.5A +12V @ 1.5A 46-46812 120V United States and Canada 46-46813 220V – 240V Continental European 46-46814 220V – 240V Unit...
Page 8 - See caution statement on page 3.
4 I NTRODUCTION G ENERAL P RECAUTIONS The following are some general precautions to remember when handling your MS2122 scanner. D O N OT T URN the unit upside down with the platter in place. D O N OT P RESS on the window in the replacement platter or the vertical window frame. P RESS on the platter’...
Page 9 - Design Specifications; Light Source: VLD 650 nm; Mechanical; For Regulatory Compliance Information refer to pages 43 - 45.; Environmental; required
5 I NTRODUCTION MS2122 D ESIGN S PECIFICATIONS Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: <2.2 mW Horizontal Depth of Field: 0 mm - 152 mm (0”- 6”) for 0.33 mm (13 mil) bar code Vertical Depth of Field: 0 mm - 216 mm (0”- 8.5”) for 0.33 mm (13 mil) bar code Scan ...
Page 10 - Components; TEM
6 B ASE M ODEL C HARACTERISTICS MS2122 Scanner Components Figure 6. MS2122 Components I TEM N O . D ESCRIPTION 1 Blue and White LED Bar 2 Volume/Tone Button (Multi-Function) 3 Diamonex or Sapphire Horizontal Window (Laser Aperture) 4 Flow Direction Indicator 5 Stainless Steel Platter (Replaceable) 6...
Page 11 - Dimensions
7 B ASE M ODEL C HARACTERISTICS MS2122 Scanner Dimensions Figure 7. MS2122 Connectors Connector Panel Figure 8. MS2122 Connectors
Page 12 - Caution
8 B ASE M ODEL C HARACTERISTICS MS2122 Scanner Caution and Serial Number Labels Figure 9. MS2122 Label Locations (Top) and Examples (Bottom) Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage)...
Page 13 - SWAP
9 I NSTALLATION Q UICK I NSTALLATION O UTLINE The following is a quick preview of the steps required for 1 st time installations. Each item is discussed in detail later in this section. • Determine clearance, ventilation and service access requirements. • Determine checkout counter layout taking int...
Page 14 - Proper Lifting Technique; Figure 15. Lifting Handles
10 I NSTALLATION U NPACKING THE U NIT 1. Make sure the shipping box is top-side up before opening. 2. Remove the accessories box and check its content for the following items. • Product Manuals • Power Supply • Communication Cable(s) 3. Lift the scanner out of the shipping box by gripping the bottom...
Page 15 - Option B
11 I NSTALLATION I NSTALLING THE U NIT IN THE C OUNTER There are two options for mounting your MS2122 scanner. Option A, is a two-point mounting system that supports the unit at the front and back. Option B , is a three-point mounting system that supports the unit at the back and on the sides. Befor...
Page 17 - Scanner RS232 to Host; Figure 18. RS232 Interface Cable Installation Schematic
13 I NSTALLATION I NTERFACE RS232 The following steps describe how to properly install the cables for an RS232 Stratos E application. The scanner must then be configured to match the host’s RS232 parameters. Cable installation alone does not guarantee that the Stratos E will communicate properly wit...
Page 18 - USB; NTEGRATED; Scanner USB to Host; IBM OEM Full Speed USB Communication; Figure 19. USB Cable Installation Schematic
14 I NSTALLATION I NTERFACE F ULL S PEED USB (I NTEGRATED ) The following steps describe how to properly install the cables for a Full Speed Stratos E application. The scanner must then be configured to match the host’s USB parameters. Cable installation alone does not guarantee that the Stratos E w...
Page 19 - IBM; XX; Scanner RS232/ IBM to Host; Scanner Configuration; Figure 20. IBM Cable Installation Schematic
15 I NSTALLATION I NTERFACE IBM 46 XX The following steps describe how to properly install the cables for an IBM 46xx Stratos E application. The scanner must then be configured to match the host’s IBM 46xx parameters. Cable installation alone does not guarantee that the Stratos E will communicate pr...
Page 20 - OCIA; Scanner OCIA to Host; Section I: OCIA for Enabling and Setting; Figure 21. OCIA Cable Installation Schematic
16 I NSTALLATION I NTERFACE OCIA The following steps describe how to properly install the cables for an OCIA Stratos E application. The scanner must then be configured to match the host’s OCIA parameters. Cable installation alone does not guarantee that the Stratos E will communicate properly with t...
Page 21 - Scanner Configuration Bar Codes:; Figure 22. AUX Cable Installation Schematic
17 I NSTALLATION S ECONDARY M ETROLOGIC S CANNER , C ABLE I NSTALLATION The following steps describe how to properly install the cables between a secondary Metrologic scanner and the Stratos E . The Stratos E and the secondary scanner must then be configured to communicate properly. Cable installati...
Page 22 - NSTALLATION; EAS; EACTIVATION; Base Model; SW1 & SW2 switches 1 and 6 set to ON; . It is important to pass the entire tag through; Figure 24. EAS Deactivation Area
18 I NSTALLATION EAS D EACTIVATION SW1 and SW2 are the switch banks inside the Checkpoint device that set the deactivation range. The following is a list of Checkpoint recommended switch bank settings. Base Model Checkpoint Recommended Switch Bank Settings MS2122 SW1 & SW2 switches 1 and 6 set t...
Page 23 - Specifications are subject to change without notice.
19 S CANNER O PERATION S CAN Z ONE Figure 25. Checker-Side (13 mil) Figure 26. Horizontal Left / Right (13 mil) Specifications are subject to change without notice.
Page 25 - IR; IR Activation Area Perpendicular to Package Flow
21 S CANNER O PERATION S CAN Z ONE Figure 29. Top-Down (13 mil) IR A CTIVATION A REA The Stratos E ’s default power save mode † is Dual Action Power Save Mode #2 (see page 26) . This power save mode † turns the laser OFF after a configured period of non-use then turns the motor OFF after thirty-minu...
Page 27 - Diagnostic Indicator Display
23 S CANNER O PERATION I NDICATOR D ESCRIPTIONS Visual Steady Blue When all lasers are active, the blue LED is illuminated. The blue LED will remain illuminated until all lasers are deactivated. Steady Blue and Single White Flash When the scanner successfully reads a bar code, the white LED will fla...
Page 28 - Figure 32. Diagnostic Indicator Display; Error; for the proper interface
24 S CANNER O PERATION I NDICATOR D ESCRIPTIONS Diagnostic Indicator Display There is a two-digit error code display located under the platter near the bottom right corner of the output window (see figure below). Figure 32. Diagnostic Indicator Display The following is a list of possible error codes...
Page 30 - MetroSelect Configuration Guide; Blink Power Save Mode:; Laser Off
26 S CANNER O PERATION P OWER S AVE M ODES The MS2122 has five configurable power save modes. Refer to the MetroSelect Configuration Guide ( MLPN 00-02407 x ) for additional information on Power Save Modes. 1. Blink Power Save Mode: Blinks the laser OFF & ON after a configured period of non-use....
Page 31 - Changing the Beeper Tone; The Multi-Function Button; Changing the Beeper Volume; Power Save Mode; Figure 34. Changing the Beeper
27 S CANNER O PERATION B EEPER O PTIONS AND B UTTON F UNCTIONS Changing the Beeper Tone Beeper tones may be configured directly or incrementally using the following bar code. The new tone will be heard followed by a short pause. Two more new tones will be heard signifying the new setting has been st...
Page 33 - Figure 37. Horizontal Scan Window Replacement
29 M AINTENANCE D AILY M AINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. For the glass window: 1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. 2. Gently wipe the scanner window. For the ...
Page 34 - Figure 38. Vertical Scan Window Replacement
30 M AINTENANCE V ERTICAL S CAN W INDOW R EPLACEMENT Figure 38. Vertical Scan Window Replacement
Page 43 - interface; The secondary scanner and the Stratos; SCHOOL
39 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT OCIA RS232 IBM 46 XX USB German 434/439 Supplements 9 9 9 9 Convert Bookland to ISBN 9 9 9 9 Bookland 979 Supplements 9 9 9 9 Convert 979 to ISBN 9 9 9 9 Convert 290 to ISBN 9 9 9 9 Reformat ISBN 9 9 9 9 Add EAN Article ID 9 9 9 9 ...
Page 44 - Figure 39. Connector Layout
40 S CANNER AND C ABLE T ERMINATIONS S CANNER P INOUT C ONNECTIONS The MS2122 scanner interfaces terminate to 10-pin modular jacks located on the bottom of the units. The serial number label indicates the model number of the scanner. EAS Auxiliary RS232 In Pin Function Pin Function 1 EAS In 1 Signal...
Page 45 - Cable Connector Configurations; Type A; No Connect
41 S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C ONFIGURATIONS Cable Connector Configurations RS232 Interface Cable, MLPN 57-57000 x -N-3 Pin Function 1 Signal Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR Input 5 Power/Signal Ground 6 Reserved 7 CTS Input 8 RTS Output 9 +5VDC F...
Page 46 - Pin; 0-Position Modular Plug; All signals are referenced from the auxiliary / secondary scanner.; Specifications subject to change without notice.
42 S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C ONFIGURATIONS Cable Connector Configurations Aux Port Configuration Cable*, MLPN 57-57008 x -N-3 Pin Function ** 1 No Connect 2 Output from the Scanner 3 Input to the Scanner 4 No Connect 5 Ground 6 - 9 No Connect 9-Pin D-Type Connector RS232 ...
Page 47 - ITE Equipment
43 R EGULATORY C OMPLIANCE S AFETY ITE Equipment IEC 60950-1; EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN: 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no ci...
Page 48 - EMC; Notice
44 R EGULATORY C OMPLIANCE EMC Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity: CISPR 24, EN 55024 Class A Devices The following is applicable when the scanner cable is greater in length than 3 meters (9.8 feet) when fully extended: Les instructions ci-dessous s’appliquent aux cables d...
Page 49 - Reorient or relocate the receiving antenna
45 R EGULATORY C OMPLIANCE EMC Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner ne dépassant pas 3 métres (9.8 pieds) de long en extension maximale: Folgen...
Page 50 - Metrologic Eria Ibérica, SL; Customer Service Department; MTLG; No.5 Xinghan Street, Xinsu Industrial Square
46 L IMITED W ARRANTY The MS2122 Stratos E ™ Series scanners are manufactured by Metrologic at its Suzhou, China facility. The MS2122 Stratos E Series scanners have a three (3) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS2122 Stratos E Series sca...