Page 5 - NTRODUCTION; Product Overview; Rapid scan speed of 100 scans per second; ODEL
1 I NTRODUCTION Product Overview Metrologic's MS9590i VoyagerGS is the first Voyager-branded product designed specifically for the light-industrial marketplace. The VoyagerGS provides an aggressive solution for scanning all standard 1D bar codes in an ergonomic form factor that maximizes comfort and...
Page 6 - Scanner and Accessories; ASIC; Available for download at; PTIONAL; Description
2 I NTRODUCTION Scanner and Accessories B ASIC K IT Part # Description MS9590 i or MS9591 i MS9590 i Industrial Bar Code Scanner or MS9591 i High-Density Industrial Bar Code Scanner 00-02544 MetroSelect Single-Line Configuration Guide 00-05343 MS9590 i VoyagerGS Industrial Series Single-Line Hand...
Page 7 - Coiled
3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part # Description Cable Compatibility Warning Use only MS9590 i series compatible product cables from the list below. Damage may occur to the scanner if incompatible cables are used. Any damage incurred from incorrect cable usage will v...
Page 8 - Scanner Components; No. Item Description; Figure 1. Scanner Components
4 I NTRODUCTION Scanner Components No. Item Description 1 Window Laser Aperture 2 Trigger See How to use CodeGate on page 16 3 Cable Connection 10-pin RJ45, Female Socket, See Scanner Pinout Connections on page 31 4 Speaker See Audible Indicators on page 17 5 White LED See Visual Indicators on page ...
Page 9 - Cable Installation and Removal; Installation; Figure 2. Connecting the Cable; click; Removal; Figure 3. Releasing the Cable; dimple
5 I NTRODUCTION Cable Installation and Removal Installation Important: If the cable is not fully latched, the unit can power intermittently. Figure 2. Connecting the Cable 1. Plug the 10-pin RJ45 end of the cable into the 10-pin socket on the scanner. There will be an audible click when the connecto...
Page 10 - Labels; has a serial number label located on the underside; Figure 4 . Molded Text and Serial Number Label
6 I NTRODUCTION Labels Every MS9590 i and MS9591 i has a serial number label located on the underside of the scanner head and molded text on the scanner handle. The label and molded text provide important information such as the unit’s date of manufacture, serial number, CE and caution information. ...
Page 12 - Applicable for IBM
8 S CANNER I NSTALLATION RS485 (-106) 1. Turn off the host device. 2. Plug the 10-pin RJ45 end of the MVC cable into the 10-pin socket on the scanner. There will be an audible click when the connector lock engages. 3. Connect the other end of the MVC cable to the host device. 4. Turn on the host...
Page 13 - must; See caution on page 6.
9 S CANNER I NSTALLATION Keyboard Wedge (-47) 1. Turn off the host device. 2. Plug the 10-pin RJ45 end of the cable into the 10-pin socket on the scanner. There will be an audible click when the connector lock engages. 3. Disconnect the host device's keyboard. 4. Connect the "Y" ends of the ...
Page 15 - USB is the default communication protocol for the MS9590
11 Figure 9. S CANNER I NSTALLATION USB (-106) 1. Turn off the host system. 2. Plug the 10-pin RJ45 end of the USB cable into the 10-pin socket on the scanner. There will be an audible click when the connector lock engages. 3. Plug the USB Type A end of the cable into the host's USB port. 4. Turn ...
Page 16 - Figure 10. Stand Components
12 S TANDS Flex Stand Components (PN 46-00709) Item Item Description Qty . A Cradle Coupler 1 B Cradle 1 C Flexible Shaft 1 D Screw Cap 2 E Stand Base 1 F ¼" - 20 x ⅜ " Flat Head Phillips Screw, 100° Undercut 2 G #8 Round Head Wood Screw 2 H M3 -.5 x 20 mm, Pan Head Phillips Screw 1 J M3 Fla...
Page 17 - TANDS; Figure 11. Stand Assembly
13 S TANDS Flex Stand Assembly (PN 46-00709) Figure 11. Stand Assembly
Page 19 - Cradle Angle Warning; Figure 16. Cradle Angle Warning
15 S TANDS Optional Wall/Tabletop Stand Fixed Mount (PN 46-00885 ) 1. Drill two #39 pilot holes in the wall spaced 39 mm (1.54") apart on a horizontal centerline. 2. Install one #8 wood screw in each of the pilot holes, leaving a space between the head of the screw and the wall surface. 3. Locat...
Page 21 - Audible; One Beep; first; During Operation; Three Beeps
17 I NDICATORS Audible During operation, the scanner provides audible feedback that indicates the status of the scanner and latest scan. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the beeper tone, refer to the MetroSelect Single-Line Conf...
Page 22 - NDICATORS; Visual; series scanner has three; Figure 18. LED Configuration; All LEDs are Off
18 I NDICATORS Visual Each MS9590 i series scanner has three LED indicators (blue, white, and yellow) located on the head of the scanner. When the scanner is in operation, the flashing, or stationary activity of the LEDs indicates the status of the scanner and the current scan. Figure 18. LED Config...
Page 23 - One Razzberry Tone – On Power Up
19 I NDICATORS Failure Modes One Razzberry Tone – On Power Up This indicates the scanner has experienced a flipper/motor failure. Return the scanner for repair to an authorized service center. Three Beeps – On Power Up If the scanner beeps 3 times on power up, verify the host and scanner are set to ...
Page 24 - Bar Codes; MetroSet
20 C ONFIGURATION M ODES The MS9590 i series scanners have three modes of configuration. • Bar Codes The scanner can be configured by scanning the bar codes located in the MetroSelect ® Single-Line Configuration Guide ( MLPN 00-02544). This manual can be downloaded FREE at www.metrologic.com. • Metr...
Page 25 - ROM; Do not; POS Scanners
21 U PGRADING THE F LASH ROM F IRMWARE The MS9590 i and the MS9591 i are part of Metrologic's line of scanners with flash upgradeable firmware. The upgrade process requires a new firmware file supplied to the customer by a customer service representative and Metrologic's MetroSet 2 software . A...
Page 26 - Depth of Field; Start; Figure 19. MS9590i Depth of Field vs. Bar Code Element Width
22 D EPTH OF F IELD MS9590 i Depth of Field (In the Field of View) Bar Code Element Width Start (From Scanner Face) End (From Scanner Face) Total .127 mm 5.0 mil 83 mm (3.3") 108 mm (4.3") 25 mm (1.0") .15 mm 5.7 mil 64 mm (2.5") 127 mm (5.0") 63 mm (2.5") .19 mm 7.5 mil 38 m...
Page 27 - Figure 20. MS9591i Depth of Field vs. Bar Code Element Width
23 D EPTH OF F IELD MS9591 i Depth of Field (In the Field of View) Bar Code Element Width Start (From Scanner Face) End (From Scanner Face) Total .10 mm 4.0 mil 25 mm (1.0") 45 mm (1.8") 20 mm (.8") .12 mm 4.8 mil 23 mm (0.9") 51 mm (2.0") 28 mm (1.1") .13 mm 5.2 mil 22 mm (0...
Page 28 - IR; CTIVATION; Specifications are subject to change without notice.
24 IR A CTIVATION R ANGE The MS9590 i series has a built in object detection sensor that instantly turns on the scanner's laser when an object is presented within the scanner's IR activation area. Refer to the MetroSelect Single-Line Configuration Guide for information on configurable IR activation ...
Page 29 - Or; Keyboard Type
25 A PPLICATIONS AND P ROTOCOLS The model number on each scanner includes the scanner number and the default communication protocol for the scanner. Scanner Version Identifier Communication Protocol(s) 14 RS232 - TXD, RXD, RTS, CTS, DTR, DSR 47 Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit...
Page 30 - Symptoms; All Interfaces; Enable beeper and select a tone.
26 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited warranty terms. Symptoms Possible Causes Solution All Interfaces No power is being supplied to the unit. Check the transforme...
Page 32 - The computer is in
28 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The next four items are only relevant for a Keyboard Wedge interface. The unit scans but the data is not correct. The unit’s configuration is not correct. Make sure that the proper PC type AT, PS2 or XT is selected. Verify the correct coun...
Page 33 - Series Specifications; PERATIONAL
29 D ESIGN S PECIFICATIONS MS9590 i Series Specifications O PERATIONAL Light Source: V isible L aser D iode 650 nm ± 10 nm Laser Power: 0.809 mW (peak) Pulse Duration: 560 µsec MS9590 i Refer to page 22 Depth of Scan Field: MS9591 i Refer to page 23 MS9590 i Refer to page 22 Width of Scan Field: MS9...
Page 34 - ECHANICAL; For regulatory compliance information see pages 35 – 37.; NVIRONMENTAL
30 D ESIGN S PECIFICATIONS MS9590 i Series Specifications M ECHANICAL Height H 1 : 160 mm (6.30") H 2 : 41 mm (1.60") Width W 1 : 65 mm (2.56") W 2 : 25.4 mm (1.00") Depth: 100 mm (3.93") Weight: 150g E LECTRICAL Input Voltage: 5VDC ± 0.25V Operating = 650 mW typical Power: Stand...
Page 35 - Scanner Pinout Connections; Keyboard Wedge and Stand-Alone
31 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections The MS9590 i and MS9591 i scanner interfaces terminate to a 10-pin modular jack. The serial number label indicates the interface enabled when the scanner is shipped from the factory. MS9590 i -14 or MS9591 i -14 RS232 Pin Function 1 Gro...
Page 36 - Cable Connector Configurations (Host End); Locking
32 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) RS232 PowerLink Cable 53-53000 x -3 Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR Input/Light Pen Source 5 Signal Ground 6 Light Pen Data (DSR Out for -14 interfaces) 7 CTS Input 8 RTS O...
Page 38 - Metrologic Eria Ibérica, SL; MTLG; Suzhou Sales Office
34 L IMITED W ARRANTY The MS9590 i Voyager GS ™ series scanners are manufactured by Metrologic at its Suzhou, China facility. The MS9590 i series scanners have a three (3) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS9590 i series scanners are fre...
Page 39 - Safety; ottici, equipaggiati con raggi
35 R EGULATORY C OMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circ...
Page 40 - EMC; meters in length when fully extended.
36 R EGULATORY C OMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Note: Immunity performance is not guaranteed for scanner cables greater than 3 meters in length when fully extended. Changes or modifications not expressly approved by the party responsible...
Page 41 - Standard Europeo; Reorient or relocate the receiving antenna; Notice; This Class B digital apparatus complies with Canadian ICES-003.; Remarque
37 R EGULATORY C OMPLIANCE EMC Standard Europeo Attenzione Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causare interferenze radio che potrebbero richiedere all’utilizzatore opportune misure. Attention Ce produit est de classe “A”. Dans un environnement dome...
Page 43 - NDEX
39 I NDEX A AC .................................. see power accessories ............................... 2, 3 adapter .......................................... 3 B beep ............................ see indicator blue LED...................... see indicator C cable.............................. 2–3, ...