Lincoln Electric SVM 122-A - Manual

Lincoln Electric SVM 122-A

Lincoln Electric SVM 122-A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111
112 Page 112
113 Page 113
114 Page 114
115 Page 115
116 Page 116
Page: / 116

Table of Contents:

  • Page 2 – SAFETY; WARNING; CALIFORNIA PROPOSITION 65 WARNINGS; The Above For Diesel Engines
  • Page 3 – ii; ELECTRIC SHOCK can kill.
  • Page 4 – iii
  • Page 5 – iv; PRÉCAUTIONS DE SÛRETÉ
  • Page 6 – MASTER TABLE OF CONTENTS FOR ALL SECTIONS; Page
  • Page 7 – TABLE OF CONTENTS; Installation; Lifting
  • Page 8 – INSTALLATION; TECHNICAL SPECIFICATIONS - IDEALARC DC-400
  • Page 9 – SAFETY PRECAUTIONS; SELECT SUITABLE LOCATION; LIFTING
  • Page 10 – INPUT CONNECTIONS; FIGURE A.1 – RATING PLATE LOCATION; GROUND CONNECTION; • Turn the input power off at the
  • Page 11 – INPUT WIRE AND FUSE SIZE; FIGURE A.3 – INPUT POWER SUPPLY CONNECTIONS
  • Page 12 – RECONNECT PROCEDURE
  • Page 13 – OUTPUT CONNECTIONS
  • Page 14 – TABLE A.1 - CABLE SIZES FOR COMBINED LENGTHS OF COPPER ELECTRODE; WIRE FEEDER CONNECTIONS; Automatic Wire Feeders:
  • Page 15 – Operation
  • Page 16 – OPERATING INSTRUCTIONS; OPERATION
  • Page 17 – GENERAL DESCRIPTION; RECOMMENDED PROCESSES; Amps; LIMITATIONS
  • Page 18 – CONTROLS AND SETTINGS; FIGURE B.1 – CASE FRONT CONTROLS; trols voltage in CV mode and current in CC mode.; OUTPUT TERMINALS “ON” OR “REMOTE”
  • Page 19 – AUXILIARY POWER AND REMOTE CONTROL; Selects between Constant; DC VOLTMETER: Displays output voltage when
  • Page 20 – WELDING OPERATION; OPERATING STEPS; LOCAL CONTROL
  • Page 23 – NOTE: These semiautomatic wire feeders cannot; be used in the CC mode.; OVERLOAD PROTECTION
  • Page 24 – Accessories
  • Page 25 – FACTORY INSTALLED OPTION; DIODE OPTION; FIELD INSTALLED OPTIONS; ACCESSORIES; MULTIPROCESS SWITCH
  • Page 26 – Multiprocess Switch Operation; The operation of the Multiprocess Switch is as follows:; Connections; ) jumper from the work; NOTE: When a DC-400 equipped with Multiprocess; jumper
  • Page 27 – • Turn the input supply power OFF
  • Page 28 – K843 AMPTROL ADAPTER INSTALLATION INSTRUCTIONS (Continued)
  • Page 29 – NOTE: The Idealarc DC-400 must be properly
  • Page 31 – NOTE: The connection diagram shown in Figure C.5; Disconnect main AC input power to the Idealarc; NOTE: Welding cable must be sized for the cur-; rent and duty cycle of the application.; K597-XX INPUT CABLE ASSEMBLY
  • Page 32 – SEMIAUTOMATIC WIRE FEEDERS; NOTE: Welding cable must be sized for the current; and duty cycle of the application.; NOTE: If optional remote control is used, place the
  • Page 35 – K595-XX INPUT CABLE ASSEMBLY
  • Page 36 – NOTE: Welding cable must be sized for the current; NOTE: If optional remote control is used, set the
  • Page 37 – Maintenance
  • Page 38 – MAINTENANCE
  • Page 39 – FIGURE D.1 – GENERAL COMPONENT LOCATIONS
  • Page 40 – Theory of Operation; FIGURE E.1 – IDEALARC DC-400 BLOCK LOGIC DIAGRAM
  • Page 41 – THEORY OF OPERATION; FIGURE E.2 – INPUT LINE VOLTAGE, CONTACTOR AND MAIN TRANSFORMER
  • Page 42 – FIGURE E.3 – OUTPUT MODE AND CONTROL, RECTIFICATION AND FEEDBACK
  • Page 44 – SCR OPERATION; FIGURE E.4 – SCR Operation
  • Page 45 – Test Procedures
  • Page 46 – HOW TO USE TROUBLESHOOTING GUIDE; TROUBLESHOOTING & REPAIR; CAUTION; The
  • Page 47 – PC BOARD TROUBLESHOOTING PROCEDURES
  • Page 48 – Observe Safety Guidelines; TROUBLESHOOTING GUIDE; detailed in the beginning of this manual.; OUTPUT PROBLEMS
  • Page 49 – Check for blown or missing
  • Page 50 – Rectifier Bridge Test.
  • Page 52 – Make certain the remote control
  • Page 53 – Check the welding Mode switch
  • Page 54 – FUNCTION PROBLEMS
  • Page 55 – Check for an internal short
  • Page 56 – WELDING PROBLEMS; Check the welding cables for
  • Page 59 – INPUT CONTACTOR TEST; DESCRIPTION
  • Page 60 – TEST PROCEDURE; Electric Shock can kill.; FIGURE F.1 – INPUT CONTACTOR CONNECTIONS
  • Page 61 – TEST FOR CONTACT CONTINUITY; Disconnect the main input supply power to; FIGURE F.2 – INPUT CONTACTOR TEST CONNECTIONS
  • Page 63 – FIGURE F.3 – CONTROL TRANSFORMER AND LEAD LOCATIONS
  • Page 64 – Read the meter for 115VAC.; FIGURE F.4 – CONTROL TRANSFORMER X1 AND X2 TEST CONNECTIONS
  • Page 66 – FIGURE F.5 – INPUT CONTACTOR, RECONNECT PANEL, AND PRIMARY LEADS
  • Page 67 – Test with an AC voltmeter for proper main; FIGURE F.6 – MAIN SECONDARY LEAD TEST POINTS
  • Page 68 – Test with an AC voltmeter for 21VAC for
  • Page 69 – Plug P1 PHASE ANGLE WINDING VOLTAGES; Expected VAC; FIGURE F.8 – CONTROL BOARD PLUG P1 LOCATION; Plug P1
  • Page 71 – STATIC SCR/DIODE RECTIFIER BRIDGE TEST; FIGURE F.9 – CONTROL BOARD AND SNUBBER BOARD PLUG LOCATIONS
  • Page 72 – Remove the red insulating paint from the; FIGURE F.11 – HEAT SINK AND SCR TEST POINTS
  • Page 74 – ACTIVE SCR TEST; FIGURE F.12 – CONTROL BOARD PLUG
  • Page 75 – FIGURE F.15 – HEAT SINK TEST POINTS
  • Page 76 – Test the voltage level of the battery. Short; FIGURE F.16 – SCR TESTER CIRCUIT AND SCR CONNECTIONS
  • Page 77 – SCOPE SETTINGS; NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM; volts
  • Page 78 – MAXIMUM OUTPUT SETTING – NO LOAD
  • Page 80 – TYPICAL OUTPUT VOLTAGE WAVEFORM – MACHINE LOADED
  • Page 82 – TYPICAL SCR GATE VOLTAGE WAVEFORM
  • Page 83 – ABNORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
  • Page 85 – FIGURE F.17 – INPUT CONTACTOR CLEANING AND REMOVAL; CLEANING PROCEDURE
  • Page 87 – FAN MOTOR AND BLADE REMOVAL AND REPLACEMENT; FIGURE F.18 – FAN MOTOR MOUNTING DETAILS; PROCEDURE; You may need to loosen the
  • Page 89 – SCR/DIODE RECTIFICER ASSEMBLY
  • Page 91 – FIGURE F.20 – SCR DETAILS; SCR REMOVAL AND REPLACEMENT; SPECIAL INSTRUCTIONS
  • Page 92 – FIGURE F.22 – CLAMP ASSEMBLY; Go to the procedure below that matches your
  • Page 93 – Do not turn the nuts. While holding the nuts
  • Page 94 – FIGURE F.23 – HOUSING AND PRESSURE PAD FOR 5/8” WIDE LEAF SPRING
  • Page 95 – AFTER REPLACING THE SCRs
  • Page 97 – Install the case top and sides.; DIODE STUD; MOUNTING OF STUD TYPE DIODES TO ALUMINUM
  • Page 99 – REMOVAL OF LIFT BAIL; MAIN TRANSFORMER REMOVAL & REPLACEMENT; FIGURE F.25 – LIFT BAIL REMOVAL
  • Page 100 – FIGURE F.26 – CHOKE REMOVAL; NOTE: The coils may be “stuck” to the top iron
  • Page 101 – FIGURE F.27 – EPOXY MIX APPLICATION AREAS; Apply a coating of Lincoln Electric E2547
  • Page 102 – FIGURE F.28 – COIL LEAD PLACEMENT
  • Page 103 – Mount the primary thermostat to the lead; FIGURE F.30 – PRIMARY THERMOSTAT LOCATION
  • Page 104 – NOTE: The following procedure assumes you have; REASSEMBLE THE LIFT BAIL
  • Page 105 – RETEST AFTER REPAIR; INPUT IDLE AMPS AND WATTS; Maximum Idle Amps; OPEN CIRCUIT VOLTAGES; Mode
  • Page 106 – MAXIMUM ACCEPTABLE OUTPUT VOLTAGE-
  • Page 108 – NOTES
  • Page 109 – ELECTRICAL DIAGRAMS
Loading the manual

SVM 122-A

Oct. 1996

Safety Depends on You

Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However,
your overall safety can be
increased by proper installation
. . . and thoughtful operation on
your part. DO NOT INSTALL,
OPERATE OR REPAIR THIS
EQUIPMENT WITHOUT READ-
ING THIS MANUAL AND THE
SAFETY PRECAUTIONS CON-
TAINED THROUGHOUT.
And,
most importantly, think before
you act and be careful.

SERVICE MANUAL

LINCOLN

®

ELECTRIC

World’s Leader in Welding and Cutting Products Premier Manufacturer of Industrial Motors

Sales and Service through subsidiaries and Distributors Worldwide

22801 St. Clair Ave. Cleveland, Ohio 44117-1199 U.S.A. Tel. (216) 481-8100

For use with machine code numbers 9847, 9848 and 9850

IDEALARC DC-400

TM

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

V

iew Safety Info

V

iew Safety Info

V

iew Safety Info

V

iew Safety Info

RETURN TO MAIN INDEX

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY; WARNING; CALIFORNIA PROPOSITION 65 WARNINGS; The Above For Diesel Engines

Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC SAFETY i i LINCOLN ® ELECTRIC IDEALARC DC-400 FOR ENGINEpowered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. _____________...

Page 3 - ii; ELECTRIC SHOCK can kill.

Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC SAFETY ii ii LINCOLN ® ELECTRIC IDEALARC DC-400 ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks andthe rays of the arc when welding or observingopen a...

Page 4 - iii

Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC SAFETY iii iii LINCOLN ® ELECTRIC IDEALARC DC-400 FOR ELECTRICALLYpowered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working onthe equipment. 8.b. Install equipment in...

Other Lincoln Electric Models

All Lincoln Electric Other