Lincoln Electric 10A - Manual

Lincoln Electric 10A

Lincoln Electric 10A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Power Feed 10A Controller; A CLOSER LOOK; FEATURES; Switch Panel
  • Page 3 – Memory panel; MSP4 and Memory Panel; Infrared IR Port; Encoder Panel Lockout
  • Page 4 – Waveform Control Technology®; AC
  • Page 5 – Single or Tandem Arc; Mounting and Motion Controls
  • Page 6 – QUALITY & RELIABILITY; ARCLINK®/LINC-NET CONTROL EXTENSION CABLES; RECOMMENDED OPTIONS; WELD POWER CABLES
  • Page 7 – GENERAL OPTIONS
  • Page 8 – T H E L I N C O L N E L E C T R I C C O M PA N Y; POWER FEED 10A CONTROLLER ORDER FORM; PRODUCT DESCRIPTION; POWER FEED 10A CONTROLLER; GENERAL OPTIONS CONT.
Loading the manual

Wire Feed

Wire Size Range

(1)

Dimensions

Product

Product

Input

Rated Output

Gear

Speed Range

(1)

Inches (mm)

H x W x D

Net Weight

Name

Number

Power

(1)

Current / Duty Cycle

Box

ipm (m/min)

Solid

Inches (mm)

lbs (kg)

Power Feed 10A

K2362-1

40 VDC

1000A/100%

142:1(1)

10-200 (.25-5.08)

5/32 - 7/32 (4.0 - 5.6)

15 x 13 x 4

25 (11.3)

Controller with

(381 x 259 x 102)

Wire Drive

95:1(1)

10-300 (.25-7.62)

1/8 - 5/32 (3.2 - 4.0)

Description

Output

Input

40

VDC

Power Feed™
10A Controller

AUTOMATIC WIRE FEEDERS

Built on the enduring and trusted foundation of the NA-5 controller and the innovations of the
new Power Feed 10M wire feeder, the Power Feed 10A Controller is the next generation in
automatic submerged arc feeding. Designed for use with the Power Wave AC/DC 1000 power
source, the Power Feed 10A eliminates the need for a separate AC and DC controller, making this
powerful hard automation system controllable, adaptable and easy to use. The user-friendly
control panel offers a single-point of control over the entire welding cell, including the Power
Wave's Waveform Control Technology™, delivering an unprecedented level of control over wave
balance, amplitude and frequency.

Publication E9.165 1/05

www.lincolnelectric.com

Advantage Lincoln

Recommended General Options

Order

TECHNICAL SPECIFICATIONS

Submerged Arc

Power Feed 10SM Motor Conversion Kit (converts Lincoln NA-style wire
drives), ArcLink Cable, Flux Hopper, Feeder Control Cable (14-pin to 14-
pin and 5-pin to 5-pin), Contact Nozzle Assembly, Contact Jaw
Assembly, Positive Contact Assembly, Linc-Fill Attachments, Narrow
Gap Deep Groove Nozzle, Concentric Flux Cone Assembly, Tandem Arc
Framework, Tandem Reels, Twinarc Contact Assemblies, Tiny Twinarc
Assemblies, Tiny Twinarc Solid Wire Straightener, TC-3 Travel Carriage,
Vertical Lift Adjuster, Horizontal Adjuster, Wire Reel Assembly for 50-60
lb. Coils, Spindle Kit – 2 in. hub, SpreadArc Oscillator, Flux Screen,
Magnetic Flux Screen Separator

K2362-1 Power Feed 10A Controller

ArcLink Controller for Power Wave AC/DC Systems.

Power Feed 10A Control Box, Remote Pendant, 10-ft. Remote Pendant
Cable

Power Wave AC/DC 1000 power source, and either the K2312-1 Power
Feed 10SF Wire Feed Head for fixed hard automation, or the K2370-1
Power Feed 10S Head for mounting to a Lincoln TC-3 Travel Carriage.
(other options may apply.)

Unit Requires:

• Versatile system set-up options for stand-alone or PLC

configurations help you customize the weld cell to make your
operations as efficient as possible.

• Lincoln’s Waveform Control Technology™ gives you the ability

to select the right waveform for each application.

• The Power Feed 10A Controller provides clear dual digital display

of set-up and weld modes, six memories, AC controls,
strike/start/end options, travel stop/start, and timers.

• Controls can be adjusted on-the-fly to change penetration and/or

deposition rates with Variable Frequency, Variable Amplitude and
Variable Balance.

• Easy-to-use switch panel can be removed and used as a Remote

Control Pendant to create a versatile work station set-up.

• The Power Feed 10SF and Power Feed 10S wire drive systems

are reliable and durable.

• The motor conversion kit allows the use of existing NA-3, NA-4,

and NA-5 feed head mounting hardware.

• Manufactured under a quality system certified to ISO 9001

requirements and ISO 14001 environmental standards.

• Three-year warranty on parts and labor.

Processes

Unit Includes:

(1) 142:1 gear box is standard. Conversion Kit supplied for conversion to 95:1 with Wire Drive (K2370-1, K2312-1, or K2311-1)

Recommended Power Source Option

Power Wave AC/DC 1000

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Power Feed 10A Controller; A CLOSER LOOK; FEATURES; Switch Panel

Power Feed 10A Controller [2] A CLOSER LOOK FEATURES www.lincolnelectric.com The Power Feed 10A control panel controls and monitors the advancedcapabilities of the Power Wave AC/DC 1000 in a single, simple, easy-to-understand user interface display panel. The Power Feed 10A com-municates using ArcLi...

Page 3 - Memory panel; MSP4 and Memory Panel; Infrared IR Port; Encoder Panel Lockout

Power Feed 10A Controller www.lincolnelectric.com [3] A CLOSER LOOK Memory panel Up to six user settings and two procedure settings can be saved andretrieved using the Memory Panel. Allows the operator to save weldparameters and set-up options, such as Timers, Start Options, EndOptions, AC Controls,...

Page 4 - Waveform Control Technology®; AC

Power Feed 10A Controller [4] A CLOSER LOOK www.lincolnelectric.com Driving Superior Welding PerformanceLincoln’s Waveform ControlTechnology controls and shapes theoutput waveforms (or weld modes)to adapt to virtually any application,material or weld position. SET-UP OPTIONS (User Preferences)Set-up...

Other Lincoln Electric Models

All Lincoln Electric Other