Lennox MPDT-332PM-B - Manual
Lennox MPDT-332PM-B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – LENNOX HEARTH PRODUCTS • MERIT; Care and Operation; WARNING
- Page 3 – National; Table 1
- Page 4 – Figure 1; Table 3; REQUIREMENTS FOR THE COMMON-; Table 2; Tables 2 and 3; Figure 1: SIT Millivolt Gas Valve; Series; Table 4
- Page 5 – HORIZONTAL VENT; LOCATION; Figure 8; COLd CLIMATE INSULATION; Figure 3: Typical Locations
- Page 6 – Figure 5; VenT TerminaTion ClearanCes; These instructions should be used as a; Vertical Vent Termination Clearances; Figures; Termination Heights For Vents; Horizontal Vent Termination Clearances; Side Elevation View; Figure 6; Figure 4 - Multiple Terminations; minimum
- Page 7 – EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS; Figure 7
- Page 8 – MINIMUM CLEARANCES TO COMBUSTIBLES; When; Hearth Extension
- Page 9 – Figure 9: Minimum Mantel Clearances; MANTEL CLEARANCES; on
- Page 10 – Side; combustible framing; Unit Secured to Framing; Header Spacing Top Standoffs; Bend up the appropriate header spacing top; PRE-INSTALLATION STEPS; See; TYPICAL INSTALLATION SEQUENCE; Remove cardboard before using appliance.
- Page 11 – FIREPLACE ANd FRAMING SPECIFICATIONS; Vent Size; Vertical Venting through the Ceiling; Frame ceiling opening: Use a plumb line from the ceiling; above the appliance to locate center of the vertical run. Cut; Viewable Glass Size; Framing
- Page 12 – FIREPLACE FRAMING SPECIFICATIONS; Left Side Front; to; • MPdT-3328 ANd MPdR-3328 Models: Dimensions A through F occur when; one 45-degree elbow is connected directly to the appliance collar.; Back wall of chase/enclosure (including any finishing materials)
- Page 13 – Use only approved vent components (see; Approved Vent Components; Note: The vent restrictor is included in the; Step 3. PREPARING APPLIANCE VENT; VENT RESTRICTOR INSTALLATION; Step 4. INSTALLING VENT SYSTEM
- Page 14 – tf; use Firestop/Spacer; Effective Vent Length; Table 7; FlexTM pipe may also be used. A Vertical Vent; Tables on this page
- Page 15 – Vent / Appliance Collar; Note - Proper venting support is very important.
- Page 16 – Swivel Joint
- Page 17 – VERTICAL VENT FIGURES/TABLES; ideal, though rise per foot run ratios that are; Ratio V to H ratio is 1:2; together under any circumstances.; Ceiling Firestop/Spacer; Ceiling
- Page 18 – to a maximum horizontal run of 20 feet.
- Page 19 – Note: An elbow may also be attached to the; TYPICAL HORIZONTAL VENT INSTALLATION
- Page 20 – tion Guard; Figure; Venting Connection and Exterior Wall Recessing of the
- Page 21 – Venting Components Required for Various Exterior Wall Thick-; HORIZONTAL VENT FIGURES/TABLES; Under no circumstances, may separate sections of; Spacer
- Page 22 – up to a maximum horizontal run of 20 feet.
- Page 24 – Radius Minimum; SECuRE FlEx; Secure Flex; Attach Adapter to Appliance
- Page 25 – Showing the Blower Wiring for the Optional; with an optional Style View Door, mount the Rocker; Note: The supplied 15 feet of 2 conductor; CAUTION; In millivolt systems, do NOT connect; Note: Electronic models must be connected to
- Page 26 – BLOWER CONTROL CIRCUIT WIRING; Junction Box; Step 7. CONNECTING GAS LINE
- Page 27 – Step 8. VERIFYING APPLIANCE; Note: lighting Instructions are also found on; Piezo
- Page 28 – GLOWING EMBERS ANd LOGS; NOTE: Turn off all electricity to the appliance; Bag of Glowing; Glowing Embers
- Page 29 – Log; Catalog Number for the entire log set: 24M15
- Page 30 – Catalog Number for the entire log set: 24M22
- Page 31 – Catalog Number for the entire log set: 24M25
- Page 33 – WARNINGS; Light appliance (follow lighting procedure; Care and Operation Instructions; Allow the burner to operate for at least 15
- Page 34 – Louver Face Models; Adjustment Rod Up; Step 12. HOOd INSTALLATION; Refer to Figures 65 and 66. All models must; See Page 5 for
- Page 35 – Figure A; APPOSITION dES MISES EN GARdE RELATIVES
- Page 36 – INSTALLATION ACCESSORIES
- Page 37 – INSTALLATION ACCESSORIES CONTINUEd; All compressed flex vents can be expanded up to two times.
- Page 38 – Millivolt; assume les responsabilités liées à la conversion.
- Page 39 – Pilot
- Page 40 – Note: If the ignitor is damaged, a replacement; Model; Propane; Table 9
- Page 41 – NOTES
MODELS
OTL Report No. 116-F-13-4
US
Portland
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
INSTALLATION INSTRUC
TIONS
MPD Direct-Vent
Gas Fireplaces
MILLIVOLT:
ELECTRONIC:
MPDT-3328CNM-B
MPDT-3328CPM-B
MPDR-3328CNM-B
MPDR-3328CPM-B
MPD-3530CNM-B
MPD-3530CPM-B
MPD-4035CNM-B
MPD-4035CPM-B
MPD-4540CNM-B
MPD-4540CPM-B
MPDT-3328CNE-B
MPDT-3328CPE-B
MPDR-3328CNE-B
MPDR-3328CPE-B
MPD-3530CNE-B
MPD-3530CPE-B
MPD-4035CNE-B
MPD-4035CPE-B
MPD-4540CNE-B
MPD-4540CPE-B
P/N 850014 Rev. V 08/2011
This manual is one of a set of two supporting this product.
Refer to P/N 875014M for Care and Operation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 850014CF.
Please read and understand these instructions
before starting installation.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l’appareil.
CONSOMMATEUR : Conservez cette notice pour
consultation ultérieure.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d’incindie ou d’explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
WARNING /AVERTISSEMENT/AVISO
• HOT GLASS WILL CAUSE
BURNS.
• DO NOT TOUCH GLASS
UNTIL COOLED.
• NEVER ALLOW CHILDREN
TO TOUCH GLASS.
• UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
• EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not t
ry to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’
s phone. Follow the gas supplier
’s
instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteu
r. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
-
L
’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le
fournisseur de gaz.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INSTALLATION INSTRUCTIONS PACKAGING The assembled vented gas fireplace heater is packaged with:• (1 set) Logs (packaged in a carton inside the firebox). • (1 bag) Glowing Embers (in bottom compart- ment). • Literat...
3 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INSTALLATION INSTRUCTIONS WARNING Improper installation, adjust- ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult ...
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INSTALLATION INSTRUCTIONS Test gauge connections are provided on the front of the millivolt and electronic gas control valve (identified IN for the inlet and OUT...