Lennox 10ACB - Manual

Lennox 10ACB

Lennox 10ACB – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 3 – WARNING; Unit must be grounded in accordance with nation-
  • Page 5 – Expansion Valve Systems; IMPORTANT; To Access Schrader Port:
  • Page 6 – Using an Electronic Leak Detector or Halide
  • Page 8 – units) should be energized 24 hours before unit; TABLE 3
  • Page 9 – TABLE 4; -- The outdoor temperature will determine which; door unit’s rating plate.; Outdoor Temp; vice port and the unit operating stably, record the
  • Page 11 – Refrigerant Sight Glass (Option Units ONLY); IRUP DQ\ VHUYLFH RU PDLQWHQDQFH WXUQ; Evaporator Coil
Loading the manual

3DJH

£

PRODUCT LITERATURE

¤1998 Lennox Industries Inc.

Dallas, Texas

VALUE 10

TM

CONDENSING UNIT

Value 10 condensing units are designed for expansion

valve (TXV) and RFC systems. Refer to Lennox engi-

neering handbook for expansion valve kits which must

be ordered separately.

SHIPPING AND PACKING LIST

1-- Assembled 10ACB condensing unit
1-- 45E copper street elbow
1-- RFCIV refrigerant metering device (bullet)
1-- Coupling -- 5/16 x 3/8” (18, 24, 30)

Check unit for shipping damage. Consult last carrier

immediately if damage is found.

GENERAL INFORMATION

These instructions are intended as a general guide and

do not supersede national or local codes in any way.

Authorities having jurisdiction should be consulted be-

fore installation.

IMPORTANT

The Clean Air Act of 1990 bans the intentional

venting of refrigerant (CFC’s and HCFC’s) as of July

1, 1992. Approved methods of recovery, recycling

or reclaiming must be followed. Fines and/or in-

carceration may be levied for non--compliance.

INSTALLATION

INSTRUCTIONS

9DOXH

70

6HULHV

$&% &RQGHQVLQJ 8QLWV

&21'(16,1* 81,76

1--1/2 through 5 ton

503,800M

2/98

Supersedes 503,755M

TABLE OF CONTENTS

VALUE 10 CONDENSING UNIT

1

. . . . . . . . . . . . . . . . . . . . .

SHIPPING AND PACKING LIST

1

. . . . . . . . . . . . . . . . . . . . . .

GENERAL INFORMATION

1

. . . . . . . . . . . . . . . . . . . . . . . . . .

10ACB UNIT DIMENSIONS

2

. . . . . . . . . . . . . . . . . . . . . . . . .

SETTING THE UNIT

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ELECTRICAL

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PLUMBING

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

REFRIGERANT METERING DEVICE

4

. . . . . . . . . . . . . . . . . .

MANIFOLD GAUGE SET

5

. . . . . . . . . . . . . . . . . . . . . . . . . . .

LIQUID & SUCTION LINE SERVICE VALVES

5

. . . . . . . . . .

LEAK TESTING

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

EVACUATION

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START-UP

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CHARGING CONSIDERATIONS

8

. . . . . . . . . . . . . . . . . . . . .

CHARGING FOR RFC SYSTEMS

9

. . . . . . . . . . . . . . . . . . . .

CHARGING FOR TXV SYSTEMS

10

. . . . . . . . . . . . . . . . . . .

SYSTEM OPERATION

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10ACB CHECK POINTS

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

WARNING

Product contains fiberglass wool.
Disturbing the insulation in this product during

installation, maintenance, or repair will expose

you to fiberglass wool. Breathing this may cause

lung cancer. (Fiberglass wool is known to the

State of California to cause cancer.)
Fiberglass wool may also cause respiratory, skin,

and eye irritation.
To reduce exposure to this substance or for further

information, consult material safety data sheets

available from address shown below, or contact

your supervisor.

Lennox Industries Inc.

P.O. Box 799900

Dallas, TX 75379--9900

/LWKR 86$

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - WARNING; Unit must be grounded in accordance with nation-

3DJH SETTING THE UNIT Refer to unit dimensions on page 2 for sizing mountingslab, platforms or supports. Refer to figure 1 for instal-lation clearances. INSTALLATION CLEARANCES FIGURE 1 36 (914 mm) *36 (914 mm) 36 (914 mm) NOTE—48 inch clearance required on top of unit. *NOTE—One side must be 36 inc...

Page 5 - Expansion Valve Systems; IMPORTANT; To Access Schrader Port:

3DJH Expansion Valve Systems Expansion valves equipped with either “Chatleff” or flare type fittings are available from Lennox. Refer to the indoor coil installation instructions or the engineer- ing handbook for applicable expansion valves for use with specific match--ups.If an expansion valve appl...

Page 6 - Using an Electronic Leak Detector or Halide

3DJH 3-- Replace stem cap. Tighten finger tight, then tighten an additional 1/6 turn. FIGURE 5 SUCTION LINE SERVICE VALVE (VALVE OPEN) SCHRADER VALVE SERVICE PORT SERVICE PORT CAP INSERT HEX WRENCH HERE TO INDOOR COIL TO OUTDOOR COIL STEM CAP SCHRADER VALVE OPEN TO LINE SET WHEN VALVE IS CLOSED (FRO...

Other Lennox Models

All Lennox Other