Lennox EL280UH - Manual

Lennox EL280UH

Lennox EL280UH – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
Page: / 51

Table of Contents:

  • Page 2 – SUPPLY AIR; FRONT VIEW
  • Page 3 – Parts Arrangement; FIGURE 1
  • Page 4 – Shipping and Packing List; Package 1 of 1 contains; Safety Information; DANGER; WARNING; Certifications
  • Page 5 – Heating Unit Installed Upstream of Cooling Unit; Gas Unit; Use of Furnace as Construction Heater
  • Page 6 – Product contains fiberglass wool.; CAUTION
  • Page 7 – FIGURE 3
  • Page 8 – FIGURE 4
  • Page 9 – Setting Equipment; The unit must be level.; Upflow Applications; Upflow Application Installation Clearances; FIGURE 8
  • Page 10 – − Single side return air with transition to accommodate 20; Refer to Engineering Handbook for additional information.; Transition; Single Side Return Air; SIDE VIEW; SIDE RETURN
  • Page 11 – Horizontal Applications
  • Page 12 – Filters; TABLE 1; Duct System; NOTE −
  • Page 13 – Venting; Mounting Screws Location; UPFlow Position; Top Vent Discharge; IMPORTANT; − Remove the four mounting screws which secure the; Left Side Vent Discharge; UPFLOW POSITION; Right Side Vent Discharge
  • Page 14 – Horizontal Position; HORIZONTAL LEFT POSITION; Side Vent Discharge; HORIZONTAL RIGHT POSITION
  • Page 15 – VENT CONNECTION UPFLOW AND HORIZONTAL POSITION
  • Page 16 – Common Venting Using Metal−Lined Masonry Chimney; General Venting Requirements
  • Page 17 – TABLE 2; Connector Diameter
  • Page 23 – Gas Piping; Gas Supply; NOTE − Capacity given in cubic feet (m
  • Page 24 – Horizontal Application
  • Page 25 – Leak Check; Electrical; Precautions and Procedures
  • Page 27 – DIP Switch Settings and On−Board Links (See figure 33)
  • Page 29 – EL280UH SCHEMATIC WIRING DIAGRAM
  • Page 30 – DIP SWITCH FUNCTIONS
  • Page 31 – Integrated Control; Select OFF
  • Page 32 – Unit Start−Up
  • Page 33 – Gas Pressure Adjustment; NOTE; Proper Combustion; ALL; High Altitude
  • Page 34 – Manifold Pressure Settings at all Altitudes; Natural; Pressure Switch and Gas Conversion Kits at all Altitudes; No Change
  • Page 35 – Other Unit Adjustments
  • Page 36 – Heating Sequence of Operation; Two−Stage Thermostat, Two Stage Heat. Dip Switch
  • Page 37 – BLOWER DATA
  • Page 39 – Service; Blower
  • Page 43 – Integrated Control Diagnostic Codes; FLASH CODE
  • Page 44 – Troubleshooting: Heating Sequence of Operation; HEATING SEQUENCE OF OPERATION; CONTINUED ON NEXT PAGE
  • Page 46 – CONTINUED
  • Page 48 – Troubleshooting: Cooling Sequence of Operation; COOLING SEQUENCE OF OPERATION
  • Page 49 – Troubleshooting: Continuous Fan Sequence of Operation; CONTINUOUS LOW SPEED FAN SEQUENCE OF OPERATION
  • Page 50 – Start−Up & Performance Check List; Gas Supply Pressure; Line Voltage; Filter; upflow furnace shown
  • Page 51 – Combustion CO; Temperatures
Loading the manual

Page 1

02/12

*2P0212*

506894−01

*P506894-01*

E

2012 Lennox Industries Inc.

Dallas, Texas, USA

UPFLOW

HORIZONTAL LEFT

HORIZONTAL RIGHT

AIR FLOW

AIR FLOW

AIR FLOW

INSTALLATION
INSTRUCTIONS

EL280UH

ELITE

®

SERIES GAS FURNACE

UPFLOW / HORIZONTAL AIR DISCHARGE

506894−01
02/2012

THIS MANUAL MUST BE LEFT WITH THE

HOMEOWNER FOR FUTURE REFERENCE

This is a safety alert symbol and should never be ignored.
When you see this symbol on labels or in manuals, be alert
to the potential for personal injury or death.

WARNING

Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person-
al injury or loss of life. Installation and service must
be performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.

CAUTION

As with any mechanical equipment, personal injury
can result from contact with sharp sheet metal
edges. Be careful when you handle this equipment.

Table of Contents

Unit Dimensions

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts Arrangement

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

EL280UH Gas Furnace

4

. . . . . . . . . . . . . . . . . . . . . . . . . .

Shipping and Packing List

4

. . . . . . . . . . . . . . . . . . . . . . . .

Safety Information

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Use of Furnace as a Construction Heater

5

. . . . . . . . . . .

General

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Combustion, Dilution & Ventilation Air

6

. . . . . . . . . . . . . .

Setting Equipment

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Filters

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Duct System

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Venting

13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gas Piping

23

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Electrical

25

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Integrated Control

31

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Unit Start−Up

32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gas Pressure Adjustment

33

. . . . . . . . . . . . . . . . . . . . . . . .

High Altitude

33

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Proper Combustion

33

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Other Unit Adjustments

35

. . . . . . . . . . . . . . . . . . . . . . . . . .

Sequence of Operation

36

. . . . . . . . . . . . . . . . . . . . . . . . . .

Blower Performance Data

37

. . . . . . . . . . . . . . . . . . . . . . . .

Service

39

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Planned Service

42

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Repair Parts List

42

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Integrated Control Diagnostic Codes

43

. . . . . . . . . . . . . . .

Troubleshooting

44

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Litho U.S.A.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SUPPLY AIR; FRONT VIEW

Page 2 Unit Dimensions − inches (mm) AIR FLOW 23 (584) (19) 3/4 (19) 1 Bottom Return Air Opening GAS PIPING INLET (Either Side) Side Return Air Opening (Either Side) 1 Bottom Return Air Opening FLUE OUTLET (Top) ELECTRICAL INLET (Either Side) SUPPLY AIR OPENING FRONT VIEW SIDE VIEW TOP VIEW AB 9/16 ...

Page 3 - Parts Arrangement; FIGURE 1

Page 3 Parts Arrangement FIGURE 1 Combustion Air Pressure Switch Combustion Air Inducer Gas Valve and Manifold Assembly Limit Switch (under collector box) Collector Box Heat Exchanger Integrated Control Indoor Blower and Motor Assembly (removed from cabinet) Indoor Blower and Motor Assembly (install...

Page 4 - Shipping and Packing List; Package 1 of 1 contains; Safety Information; DANGER; WARNING; Certifications

Page 4 EL280UH Gas Furnace The EL280UH unit is shipped ready for installation in theupflow or horizontal right position (for horizontal left posi-tion the combustion air pressure switch must be moved).The furnace is shipped with the bottom panel in place. Thebottom panel must be removed if the unit ...

Other Lennox Models

All Lennox Other