La Crosse Technology WS-7013TWC - Manual

La Crosse Technology WS-7013TWC

La Crosse Technology WS-7013TWC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
Page: / 23

Table of Contents:

  • Page 3 – TABLE OF CONTENTS; Topic Page
  • Page 4 – INVENTORY OF CONTENTS; One strip of double sided adhesive tape.; ADDITIONAL EQUIPMENT; Philips screwdriver.
  • Page 6 – Remove the mounting bracket.; TEMPERATURE STATION; After the batteries are installed,; DO; press any buttons. This may interfere
  • Page 8 – SET
  • Page 10 – To reset both the minimum and; ADDING ADDITIONAL; The WS-7013U is able to receive
  • Page 11 – Note: When setting up multiple
  • Page 12 – VIEWING AND OPERATING; CH
  • Page 13 – MOUNTING; To achieve a true temperature; REMOTE CONTROL SENDER; Remove the mounting bracket from; THE TEMPERATURE STATION
  • Page 16 – Each temperature sensor is
  • Page 17 – Do not submerge in water.
Loading the manual

Quick Start for your WS-7013U

Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries.

1.

Have the indoor station and outdoor remote 3 to 5 apart.

2.

Batteries should be out of both units for 10 minutes.

3.

Place the batteries into the

outdoor remote

first then into the indoor station.

(All outdoor remotes must be started before the indoor station)

4.

DO NOT PRESS ANY BUTTONS FOR 10 MINUTES.


In this time the display and sensor will start to talk to each other and the display will show both the indoor
temperature and an outdoor temperature. If the station does not display both temperatures after the 10
minutes please retry the set up as stated above. After both indoor and outdoor temperatures are displayed
for 10 minutes you can place your sensor outdoors and set your time.

The remote sensor should be placed in a dry, shaded area. The remote sensor has a range of 80 feet. Any
walls that the signal will have to pass through will reduce distance. An outdoor wall or window will have
20 to 30 feet of resistance and an interior wall will have 10 to 20 feet of resistance. Your distance plus
resistance should not exceed 80 ft. in a straight line.

NOTE:

Fog and mist will not harm your remote sensor but direct rain must be avoided.


To complete the set up of your temperature station after the 10 minutes have passed please follow the steps
below.

1.

Press and hold the SET button for 5 seconds.
A 12h or 24h will appear on the top line. (12h for AM/PM, 24h for military time)

a.

To change between 12h and 24h press and release the MIN/MAX button.
When you have your choice shown on the display press and release the SET button
once.

2.

Degree Fahrenheit will now show.

a.

To change between Fahrenheit and Celsius, press and release the MIN/MAX button.
When you have your choice shown on the display press and release the SET button
once.

3.

An hour will now be flashing.

a.

Press and release the MIN/MAX button until the correct hour is shown.

NOTE:

When in the 12h mode there is “PM” displayed under the word TIME when in the PM

hours. During the AM hours this area will be blank.

When the correct hour is shown press and release the SET button once.

4.

A minute will now be flashing.

a.

Press and release the MIN/MAX button until the correct minutes are displayed.

Press and release the SET button once more and you are done.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - TABLE OF CONTENTS; Topic Page

2 TABLE OF CONTENTS Topic Page Inventory of Contents 1 Quick Setup 2 Detailed Setup Guide Battery Installation 3-4 Setting the Time 5 Selecting Units of Measurement 6 Features Minimum and Maximum Temperatures 6-7 Resetting Minimum and Maximum Temperatures 7 Additional remote control senders (optiona...

Page 4 - INVENTORY OF CONTENTS; One strip of double sided adhesive tape.; ADDITIONAL EQUIPMENT; Philips screwdriver.

1 INVENTORY OF CONTENTS 1. The Indoor Temperature Station (Figure 1) 2. The Remote Control Sensor (TX2U) and mounting bracket. (Figure 2) 3. 3 each, 1/2” Philips screws. 4. One strip of double sided adhesive tape. 5. Instruction Manual and Warranty Card. ADDITIONAL EQUIPMENT (not included) 1. 1 Phil...

Page 6 - Remove the mounting bracket.; TEMPERATURE STATION; After the batteries are installed,; DO; press any buttons. This may interfere

3 DETAILED SETUP GUIDE I. BATTERY INSTALLATION A. REMOTE CONTROL SENDER 1. Remove the mounting bracket. 2. Remove battery cover 3. Observing the correct polarity, install 2 AAA batteries—make sure they do not spring free, or start-up problems may occur. Replace cover. B. TEMPERATURE STATION Note: Af...

Other La Crosse Technology Models

All La Crosse Technology Other