Page 2 - PROFESSIONAL WEATHER CENTER; Instruction Manual; INSTANT TRANSMISSION; is the; INSTANT; offers you an; This product offers:; Weather Center; Time alarm function
2 PROFESSIONAL WEATHER CENTER Instruction Manual Congratulations on purchasing this state-of-the-art Professional W eather Center as an example of excellent design and innovative technology. Featuring time, date, calendar, weather forecast, wind direction and speed, rainfall, outdoor temperature and...
Page 3 - Wind Sensor
4 x MIN/MAX value of outdoor temperature and humidity display with time & date of recording x Low/High outdoor temperature and humidity alarm x Relative air pressure displayed in inHg or hPa x Air pressure tendency indicator for the past 12 hours (bar graph format) x LCD contrast selectable x Lo...
Page 4 - Positioning; First insert the batteries into the thermo-hygro sensor; nsert the batteries into the W eather Center (see “; How to install and; below
6 Cable connection between the wind sensor and the thermo-hygro sensor Cable connection between the rain sensor and the thermo-hygro sensor Wireless transmission at 915 MHz - thermo-hygro sensor to the Weather Center Weather Center Wind Sensor Rain Sensor SETTING UP: Note: When putting the W eather ...
Page 5 - Time and date shall be manually set (See; Manual Setting; or reflect a much larger portion of the sensor’s signal
8 displayed on the W eather Center. If this does not happen after 30 seconds, the batteries will need to be removed from both units. You will have to start again from step 1. 5. You may then check all cables for correct connection and all components for correct function by manually turning the wind-...
Page 6 - hygro sensor works with 2 x “AA”
10 x After batteries are installed, there will be synchronization between W eather Center and the sensor. At this time, the signal reception icon will be blinking. When the signal is successfully received by the W eather Center, the icon will be switched on. (If it is not successful, the icon will n...
Page 7 - SET key; In normal display mode, press and hold to switch on/off the Buzzer
12 and this code must be received and stored by the W eather Center in the first 30 seconds of power being supplied to it. BATTERY CHANGE: It is recommended to replace the batteries in all units every 24 months to ensure optimum accuracy of these units. Please participate in the preservation of the ...
Page 8 - ALARM key; LCD SCREEN
14 x In the weather alarm setting mode, press and hold to adjust different alarm value and switch the alarm On/Off x Press to activate the reset mode when max or min record is shown x Stop the alarm during the time alarm or weather alarm ringing + key x Press to change the calendar display to the pr...
Page 9 - SET; MANUAL TIME SETTING; Digit flashing
16 Air pressure histogram Outdoor temperature in °F or ºC Wind direction display and wind speed in Beaufort scale Calendar display Weather tendency indicator Time display Time alarm icon Outdoor relative humidity in % Weather forecast icon Relative air pressure display in inHg or hPa O td l ti Wind ...
Page 10 - MANUAL TIME SETTING:; SETTING; CALENDAR SETTING; Minutes flashing; TEMPERATURE UNIT SETTING
18 MANUAL TIME SETTING: You then may manually set the time of the clock by following the steps below: 1. The hour digit will start flashing. 2. Use the + or MIN/MAX key to set the hour. 3. Press the SET key to switch to the minutes. The minute digit will start flashing. 4. Use the + or MIN/MAX key t...
Page 11 - “mm”; Flashing
20 °F/°C TEMPERATURE UNIT SETTING The temperature display can be selected to show temperature data in °F or °C. (default °F) 1. The temperature unit is flashing 2. Use the + or MIN/MAX key to toggle between “°F” or “°C”. Confirm with the SET key and enter the WIND SPEED UNIT SETTING WIND SPEED UNIT ...
Page 13 - WEATHER TENDENCY INDICATOR; TIME ALARM SETTING; he “ALARM”
24 STORM WARNING THRESHOLD VALUE SETTING You may also define a switching sensitivity value for the storm warning display at a decrease of air pressure from .09 inHg to .27 inHg over 6 hours (Default 0.15 inHg). 1. The sensitivity value will start flashing. 2. Use the + or MIN/MAX key to select the v...
Page 14 - WEATHER ALARM OPERATIONS
26 4. Press the + or MIN/MAX key to set the minute of the alarm time. Press the ALARM key to confirm. W ait for about 30 seconds and the display will return to normal display mode automatically. 5. In the normal display mode, press the ALARM once key to go to the time alarm setting mode again. Then ...
Page 15 - High alarm
28 Default alarm values: Temperature Low 32 q F High 104 q F Relative Humidity Low 45% High 70% Wind speed High 62.0mph HIGH AND LOW OUTDOOR TEMPERATURE ALARM SETTING Note: The High and Low outdoor temperature alarm can be set On/Off independently, according to your needs. Set the Outdoor temperatur...
Page 17 - ALARM; HYSTERESIS; Weather data; WEATHER FORECAST AND WEATHER TENDENCY; WEATHER FORECASTING ICONS:; Sunny; change in the air press r; Rainy
32 4. Press the ALARM key once to return to the normal display mode. In case the wind speed exceeds the condition for high wind speed alarm, the value will be flashing, along with the corresponding high alarm icon ("HI AL"). And the buzzer will ring for 2 minutes. User may press any key to s...
Page 19 - WIND DIRECTION AND WIND SPEED MEASUREMENT; Wind chill in
36 The horizontal axis represents the last 12 hours air pressure recording (-12, -9, -6, -3 and 0 hour). The bars are plotted at each of the 5 steps and give the trend over the recorded period. The scale on the right compares the result. The "0" in the middle of this scale determines the cur...
Page 20 - RAINFALL MEASUREMENT; VIEWING THE MIN/MAX WEATHER DATA; VIEWING THE HISTORY DATA; the
38 RAINFALL MEASUREMENT The total rainfall measurement is displayed in the fourth section of the LCD, in the unit of mm or inch. (see VIEWING THE MIN/MAX WEATHER DATA below) VIEWING THE HISTORY DATA The W eather Center can store up to 200 sets of weather data which are recorded automatically at 3-ho...
Page 21 - key in normal; Min outdoor temperature with the date and time of recording
40 2. Press MIN/ MAX to view older records. (Press MIN/MAX and + key to view "Previous" and "Next" record respectively. The records are made at 3-hour intervals) Note: x The stored history records will not be retained after battery change or whenever battery is removed. x The total r...
Page 23 - key to show the desired weather data. For instance, if you want
44 8. Max relative pressure with the date and time of recording MAX icon MAX relative pressure value Time and date or recording 45 9. Maximum wind speed RESET THE MIN/MAX WEATHER DATA To reset the aforementioned MIN/MAX weather data 1. to 9., you shall need to reset each of the data independently. 1...
Page 24 - Total rainfall amount; SWITCHING ON/OFF THE BUZZER
46 2. Press and hold the SET key for about 2 seconds, then the "RESET" icon will appear at the bottom part of the LCD. 3. Press the + key once, then the stored value will be reset to the current value and current time. 4. Press the ALARM key to return to normal display mode. 10. Total rainfa...
Page 25 - Setting up; OUTDOOR SENSOR 915 MHz RECEPTION; outdoor display shows “
48 To re-enable the buzzer: 1. When the BUZZER OFF icon is shown on LCD, press the SET key shortly and the BUZZER OFF icon will disappear. 2. Press ALARM key once to return to the normal display mode. The "BUZZER OFF" icon will no longer be shown. Then the alarm will sound normally. LOW BATT...
Page 26 - reset all units (see; above) otherwise transmission problems may; POSITIONING; Using extension cables will shorten battery life.
50 reset all units (see Setting up above) otherwise transmission problems may occur. x During normal operation, after the outdoor display shows "- - -", the W eather Center will change to receive the outdoor data every 15 minutes, until the data is read again. Then the reception period will ...
Page 27 - Wall Bracket; Wind fan
52 Thermo-hygro Sensor An ideal mounting place for the thermo-hygro sensor would be the outer wall beneath the extension of a roof, as this will protect the sensor from direct sunlight and other extreme weather conditions. To wall mount, use the 2 screws to affix the wall bracket to the desired wall...
Page 28 - Rain Sensor; CARE AND MAINTENANCE:; Do not submerge the units in water.
54 Rain Sensor For best results, the rain sensor should be securely mounted onto a horizontal surface about 1 meter above the ground and in an open area away from trees or other coverings where rainfall may be reduced causing inaccurate readings. When securing into place, check that rain excess will...
Page 29 - LIABILITY DISCLAIMER
56 Wind speed : 0 to 111.8 mph (0 to 50 m/s) (displayed "OF.L" when > 50m/s) Wind chill : -40°F to +139.8°F (-40ºC to +59.9ºC) (displayed "OF.L" if outside this) Relative pressure pre-set range : 27.14 to 31.90 inHg (919 to 1080 hPa) Rainfall : 0" to 393.7" (0 to 9999 mm) ...
Page 30 - WARRANTY INFORMATION; Warranty Information; logy, Ltd or La Crosse Technology, Ltd’s authorized service center.
58 WARRANTY INFORMATION Warranty Information La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship. This limited warranty begins on the original date of purchase, is valid only on products purchased and used in North A...
Page 31 - La Crosse Technology, Ltd
60 This warranty gives you specific legal rights. You may also have other rights specific to your State. Some States do not allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you. For warranty work, technical support, or informatio...