Page 2 - Operating Instructions; To be handed to the operator; Environmental protection; Cleaning liquids; Important
Operating Instructions To be handed to the operator Read these instructions carefully before starting up the unit Retain for future reference Notes about these operatinginstructions Before starting up the interior cleaner for thefirst time, please carefully read throughthese instructions. In particu...
Page 3 - Table of contents
English SHD-R 3000 5.956-486 A2005937 (06/03) A. For your safety 1. Safety information and instructions 2. Noise protection 3. Authorized operators 4. Personal protective equipment 5. Emergency drill 6. Safety devices 7. Applicable regulations 8. Using the system for its intended purpose 9. Special ...
Page 4 - English; Safety information; detergents and solvents,; Authorized operators; Health hazard due to cleaning fluids.
SHD-R 3000 English 5.956-486 A2005937 (06/03) 1. Safety information and instructions The following symbols are used throughoutthese Operating Instructions: ! Danger! Denotes an immediate and present danger.Failure to observe this notice could lead tosevere injury or death. Caution! Denotes a potenti...
Page 5 - Turn off supply of cleaning liquid.; Safety valve; Applicable regulations; Accident prevent regulations
English SHD-R 3000 5.956-486 A2005937 (06/03) A2 A. For your safety 5. Emergency drill Turn mains supply voltage off at systemmaster switch. Turn off supply of cleaning liquid. If a handgun is being used, release anyremaining pressure in the system bypressing the lever on the handgun. 6. Safet...
Page 6 - Using the system for its
SHD-R 3000 English 5.956-486 A2005937 (06/03) A3 8. Using the system for its intended purpose This system is used for pumping a cleaningliquid at high-pressure, for the purpose of: with the handgun attached – cleaningcontainers, boxes, cases and equipmentparts, etc. with the interior cleaner att...
Page 7 - Schematic diagram of area classification
English SHD-R 3000 5.956-486 A2005937 (06/03) A4 A. For your safety 10. Schematic diagram of area classification
Page 8 - Area Classification
SHD-R 3000 English 5.956-486 A2005937 (06/03) A5 A. For your safety 11. Area Classification In the BetrSichV and EN 1127-1, hazardous(potentially explosive) areas are classifiedinto zones according to the frequency andduration of the occurrence of hazardous,potentially explosive atmospheres. It is t...
Page 9 - The static system; B. Types of system, and operating information; The mobile system
English SHD-R 3000 5.956-486 A2005937 (06/03) 1. Types of system Static or mobile systems The static system is intended to be installed on a base, has been mounted onto a rigid steelframe, is most suitable for use in conjunctionwith fixed-installation high-pressure lines. B. Types of system, a...
Page 10 - Water with
SHD-R 3000 English 5.956-486 A2005937 (06/03) B2 B. Types of system, and operating information Cleaning liquids Type of system (see rating plate) Cleaning liquid Working pressure/Pressure setting forsafety valve [bar] Comments SHD-R 3000 (F) - Water - VE -water * - Water with Kärcher-RM 50/65 Standa...
Page 11 - SSR; Water; VE; RM; immediately after use!
English SHD-R 3000 5.956-486 A2005937 (06/03) B3 B. Types of system, and operating information Cleaning liquids Type of system (see rating plate) Cleaning liquid Working pressure/Pressure setting forsafety valve [bar] Comments SHD-R 3000 (F) SSR - Water - VE -water - Water with Kärcher-RM - Acids 1)...
Page 12 - – Solvents
SHD-R 3000 English 5.956-486 A2005937 (06/03) B. Types of system, and operating information B4 Cleaning liquids Type of system (see rating plate) Cleaning liquid Working pressure/Pressure setting forsafety valve [bar] Comments SHD-R 3000 (F) SLA – Water – VE water* – Water with Kärcher-RM– Alkali so...
Page 13 - Emergency drill; You could lose your balance.; Starting up the system
English SHD-R 3000 5.956-486 A2005937 (06/03) B5 B. Types of system, and operating information 2. System start-up Emergency drill Turn mains supply voltage of at systemmaster switch. Turn off supply of cleaning liquid. If a handgun is being used, release anyremaining pressure in the system byp...
Page 15 - Cleaning liquid is taken in by the piston.; Features of the high-pressure pump; Horizontal construction.; Drive for the high-pressure pump
English SHD-R 3000 5.956-486 A2005937 (06/03) C2 C. System functions Operational sequence of the high-pressure pump Cleaning liquid is taken in by the piston. Suction valves (9) prevent cleaning liquidfrom flowing backwards. Action of piston pumps cleaning liquidonwards. Pressure valves (10)...
Page 16 - D. Technical specifications
SHD-R 3000 English 5.956-486 A2005937 (06/03) D1 D. Technical specifications Unit SHD-R 3000 (F) SHD-R 3000 (F) S SHD-R 3000 (F) SSR 1) SHD-R 3000 (F) SLA 1) SHD-R 3000 (F) SVA SHD-R 3000 (F) LM Electrical connection Type of current Frequency Hz 3~50* 3~50* 3~50* Voltage V 400** 400** 400** Motor ra...
Page 17 - E. Care and maintenance; General information; replacement and wearing parts; Maintenance agreement
English SHD-R 3000 5.956-486 A2005937 (06/03) E1 E. Care and maintenance 1. General information It is a fundamental requirement for ensuringthat this system functions safely and reliablythat maintenance is carried out regularly inaccordance with the following schedule. Use only original spare parts ...
Page 18 - Maintenance schedule
SHD-R 3000 English 5.956-486 A2005937 (06/03) E2 E. Care and maintenance 2. Maintenance schedule Frequency Type of pump SHD-R 3000(F) Action Procedure By whom? 1, 2, 4, 10 hours afterinitial start-up. LM SLASSR Regulate tension in compression glands See Maintenance Tasks Operator Onceonly after firs...
Page 20 - Changing the oil; Oil change procedure:
SHD-R 3000 English 5.956-486 A2005937 (06/03) E4 E. Care and maintenance 3. Maintenance tasks Changing the oil ! Danger! Burns hazard due to hot oil and hot systemcomponents. Allow pump to cool down for15 minutes before changing oil. i Important! Waste oil may only be disposed of by theoperators of ...
Page 21 - Test tension of V-belt and adjust as follows:
English SHD-R 3000 5.956-486 A2005937 (06/03) E5 E. Care and maintenance V-belt Test tension of V-belt and adjust as follows: Switch off system, and ensure that itcannot be switched back on againunintentionally. Remove guard over V-belt. Test belt tension.Press down on belt which should notmov...
Page 25 - Float tank with float valve; G. Mounting kits and accessories; Volume control valve; The pressure switch; Pulsation damper; Function
English SHD-R 3000 5.956-486 A2005937 (06/03) ! H a z a r d ! The following mounting and accessory kitsmust not be used for operation with solventsor in a hazardous (potentially explosiveatmosphere) area. 1. Mounting kits (non-hazardous area) Float tank with float valve Function The float valve fi...
Page 26 - Pressure-relief valve; check detergent reservoir regularly,
SHD-R 3000 English 5.956-486 A2005937 (06/03) G2 Pressure-relief valve Function The pressure-relief valve is an integratedsolenoid valve. The pressure-relief valve is only activeduring the start-up phase when thesystem is configured for star-deltastarting. When the pressure-relief valve is ope...
Page 33 - I. System installation; This system should only be installed by; Unpacking the system; For static systems; Preparing the installation site; Secure in position with suitable materials.; For static and mobile systems; Electrical connections; Start up the system; Switching off in an emergency
English SHD-R 3000 5.956-486 A2005937 (06/03) I1 I. System installation This system should only be installed by Kärcher Customer Service engineers, persons who have been speciallyauthorized by Kärcher. Unpacking the system Unpack the system and deliver the packag-ing materials to an appropriate ...
Page 34 - Static system
SHD-R 3000 English 5.956-486 A2005937 (06/03) I. System installation I2 Dimensional diagram: Static system Mobile system approx. 1100
Page 35 - J. Declaration of Conformity; EC Declaration of Conformity; High-pressure cleaner
English SHD-R 3000 5.956-486 A2005937 (06/03) J1 J. Declaration of Conformity EC Declaration of Conformity We herewith declare that the design andtype of machine named in the following aswell as the model marketed by us complieswith the relevant fundamental health andsafety requirements of the EC Di...