Johnson Controls F) - Manual
Johnson Controls F) – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Johnson Controls Unitary Products; LIMITATIONS; The maximum allowable line length for this product is 75 feet.; SECTION III: UNIT INSTALLATION; LOCATION; Provide an adequate structural support.; Ambient Air Temperature; NOTICE; Typical Installation
- Page 3 – GROUND INSTALLATION; Apply with Models; All; Installation of Vapor Line; TO OUTDOOR UNIT
- Page 4 – PRECAUTIONS DURING BRAZING OF LINES; Connect the refrigerant lines using the following procedure:; Replace the Schrader core in the liquid and vapor valves.
- Page 5 – SECTION IV: ORIFICE INSTALLATION; Install Schrader Valve Core and Orifice as follows:; Replace black plastic cap on equalizer fitting.; SECTION V: TXV INSTALLATION; Loosen and remove distributor cap seal.; SECTION VI: EVACUATION; Orifice Installation; Only 1TVM900 series valves are to be used on this product.
- Page 6 – SECTION VII: SYSTEM CHARGE; Total system charge is determined as follows:; SUPERHEAT CHARGING METHOD -; Do not leave the system open to the atmosphere.
- Page 7 – SECTION VIII: ELECTRICAL; GENERAL INFORMATION & GROUNDING; Run power wiring from the disconnect switch to the unit.; Contactor
- Page 8 – FIELD CONNECTIONS CONTROL WIRING; Replace the corner cover removed in Step 2.
- Page 9 – Thermostat Chart - Single Stage AC with PSC Air Handler; Single Stage Air Conditioner
- Page 11 – Thermostat Chart - Single Stage AC with PSC Furnace
- Page 13 – SECTION IX: INSTRUCTING THE OWNER; MAINTENANCE
- Page 14 – SECTION X: WIRING DIAGRAM; Wiring Diagram - Single Phase
- Page 17 – SECTION XI: START UP SHEET; Air Conditioning and Heating Start-Up Sheet; Owner Information
- Page 18 – Copyright; York International Corp.
Johnson Controls Unitary Products
872678-UIM-C-0213
R-410A
OUTDOOR SPLIT-SYSTEM
AIR CONDITIONING
MODELS: 13 & 14.5 SEER -
TCG(D,F)/GCGD/TCJ(D,F)/YCJ(D,F) SERIES
1.5 TO 6.3 TONS – 1 & 3 PHASE
INSTALLATION MANUAL
®
LIST OF SECTIONS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ORIFICE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
TXV INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
EVACUATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SYSTEM CHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
INSTRUCTING THE OWNER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
START UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
LIST OF FIGURES
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation of Vapor Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Underground Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Heat Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Orifice Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Outdoor Unit Control Box (Single Phase) . . . . . . . . . . . . . . . . . . . . . . 7
Outdoor Unit Control Box (Three Phase) . . . . . . . . . . . . . . . . . . . . . . . 7
Typical Field Wiring (Air Handler / Electrical Heat) (Single-Phase) . . . 8
Typical Field Wiring (Air Handler / Electrical Heat) (Three-Phase) . . . 8
Thermostat Chart - Single Stage AC with PSC Air Handler . . . . . . . . 9
Thermostat Chart - Single Stage AC with PSC Air Handler . . . . . . . 10
Thermostat Chart - Single Stage AC with PSC Furnace . . . . . . . . . 11
Thermostat Chart - Single Stage AC with PSC Furnace . . . . . . . . . 12
Wiring Diagram - Single Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Wiring Diagram - Three Phase 2.5-5 Tons . . . . . . . . . . . . . . . . . . . . 15
Wiring Diagram - Three Phase 6.3 Ton . . . . . . . . . . . . . . . . . . . . . . 16
24 VAC Connection Wiring for 2-pipe A/C, 6.3 Ton
Condensing Unit with 7.5 Ton Air Handler . . . . . . . . . . . . . . . . . . . . 16
LIST OF TABLES
Application Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
R-410A Saturation Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SECTION I: GENERAL
The outdoor units are designed to be connected to a matching indoor
coil with sweat connect lines. Sweat connect units are factory charged
with refrigerant for a matching indoor coil plus 15 feet of field-supplied
lines.
The refrigerant charge may need to be changed for some indoor-out-
door unit combinations, elevation differences or total line lengths. Refer
to Application Data covering “General Piping Recommendations and
Refrigerant Line Length” (Part Number 247077).
SECTION II: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words
DANGER
,
WARNING
, or
CAUTION
.
DANGER
indicates an
imminently
hazardous situation, which, if not
avoided,
will result in death or serious injury
.
WARNING
indicates a
potentially
hazardous situation, which, if not
avoided,
could result in death or serious injury
.
CAUTION
indicates a potentially hazardous situation, which, if not
avoided
may result in minor or moderate injury
. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
INSPECTION
As soon as a unit is received, it should be inspected for possible dam-
age during transit. If damage is evident, the extent of the damage
should be noted on the carrier’s delivery receipt. A separate request for
inspection by the carrier’s agent should be made in writing. See Local
Distributor for more information.
Requirements For Installing/Servicing R-410A Equipment
•
Gauge sets, hoses, refrigerant containers, and recovery system
must be designed to handle the POE type oils, and the higher
pressures of R-410A.
•
Manifold sets should be high side and low side with low side
retard.
•
All hoses must have a 700 psig service pressure rating.
•
Leak detectors should be designed to detect HFC refrigerant.
•
Recovery equipment (including refrigerant recovery containers)
must be specifically designed to handle R-410A.
•
Do not use an R-22 TXV.
•
A liquid-line filter drier is required on every unit.
This product must be installed in strict compliance with the
enclosed installation instructions and any applicable local, state,
and national codes including, but not limited to building, electrical,
and mechanical codes.
R-410A systems operate at higher pressures than R-22 systems.
Do not use R-22 service equipment or components on R-410A
equipment. Service equipment
Must Be Rated
for R-410A.
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer or service agency.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
872678-UIM-C-0213 2 Johnson Controls Unitary Products LIMITATIONS The unit should be installed in accordance with all National, State andLocal Safety Codes and the limitations listed below: 1. Limitations for the indoor unit, coil, and appropriate accessoriesmust also be observed. 2. The outdoor uni...
872678-UIM-C-0213 Johnson Controls Unitary Products 3 GROUND INSTALLATION The unit should be installed on a solid base that is 2” (5.1 cm) abovegrade and will not shift or settle, causing strain on the refrigerant linesand possible leaks. Maintain the clearances shown in Figure 1 andinstall the unit...
872678-UIM-C-0213 4 Johnson Controls Unitary Products PRECAUTIONS DURING BRAZING OF LINES All outdoor unit and evaporator coil connections are copper-to-copperand should be brazed with a phosphorous-copper alloy material suchas Silfos-5 or equivalent. DO NOT use soft solder. The outdoor unitshave re...