Johnson Controls A19B - Manual

Johnson Controls A19B

Johnson Controls A19B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
Page: / 10

Table of Contents:

  • Page 2 – Catalogue Section 1; © 2003 Johnson Controls Inc.; -2 closes on temperature increase
  • Page 3 – ensor styles
  • Page 4 – ype number selection table:
  • Page 6 – Dimension A; Duct flange to be used with closed-tank
  • Page 7 – Reset lever
  • Page 8 – pecifications; According to low voltage directive and EMC directive
  • Page 9 – Instruction sheet
Loading the manual

European Refrigeration Controls Catalogue

Catalog Section

1

Product Bulletin

A19A

Issue

03/03/2003

© 2003 Johnson Controls Inc.

Catalogue Section 1

Order No. PD-A19A-E

PSC9705

I

ntroduction

These thermostats are designed for

refrigeration, cooling, heating, ventilation and

air-conditioning applications. Standard models

are provided for remote sensing or room

sensing. Models with manual reset are

available for low or high limit functions.

D

escription

These thermostats are available with fixed or

adjustable differential. The various control

ranges cover a broad range of temperature

applications with a minimum number of models.

On request a built-in high or low limit stop is

possible and can be adjusted quickly and easily

in the field. All models have a universal way of

adjustment. For this purpose a knob and sealing

cap are enclosed.

All A19 style 1 wholesaler code models have a

bulb clamp plus screw also enclosed.

A19A capillary thermostat

A19B space thermostat

Feature and Benefits

‰

Liquid filled sensing element

No cross ambient temperature problems

Contact differential over the whole range

‰

Dust tight Penn switch

Prevents pollution of the contacts by
electrostatic influences.

‰

Trip free manual reset

Override is not possible in the control function

‰

Front adjustment

Less mounting space required.

Series A19A/A19B/A19D

Thermostats for Refrigeration, Cooling, Heating, Ventilation

and Air-conditioning

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Catalogue Section 1; © 2003 Johnson Controls Inc.; -2 closes on temperature increase

A19A Issue 03/03/2003 Catalogue Section 1 © 2003 Johnson Controls Inc. Order No. PD-A19A-E 2 N ote These controls are designed for use only as operating controls. Where an operating control failure would result in personal injury or loss of property it is the responsibility of the installer to add d...

Page 3 - ensor styles

A19AIssue 03/03/2003 © 2003 Johnson Controls Inc. Catalogue Section 1 Order No. PD - A19A-E 3 S ensor styles Fig. 4 Style 1a (drawn bulb) Fig.5 Style 1b swaged bulb, can be used with closed-tank connector FTG13A-600 ½ " x 14 NPT 33.3 60 Fig. 6 Style 4h ½" x 14 NPT 58.3 60 Fig. 7 Style 2 Fig....

Page 4 - ype number selection table:

A19A Issue 03/03/2003 Catalogue Section 1 © 2003 Johnson Controls Inc. Order No. PD-A19A-E 4 T ype number selection table: Range( °C) Diff.(K) Bulb style Setting (see page 2 adjustment) Cap. length Max.bulbtemp. Wholesalercode Ordernumber Type A19AAC Capillary thermostat, fixed differential -35 to +...

Other Johnson Controls Models

All Johnson Controls Other