Page 2 - WARNING; ACCESSORIES
WARNING Perfecto 2 ™Series 2 Part No 1150713 WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner ’s manual...
Page 3 - TABLE OF CONTENTS
TABLE OF CONTENTS Part No 1150713 3 Perfecto 2 ™Series ACCESSORIES .................................................. 2SPECIAL NOTES ............................................... 4LABEL LOCATION ............................................ 6SECTION 1—GENERAL GUIDELINES .....................7 Radio...
Page 4 - SPECIAL NOTES; NOTICE; SIGNAL WORD
SPECIAL NOTES Perfecto 2 ™Series 4 Part No 1150713 SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. Refer to the following table for definiti...
Page 5 - CAUTION
SPECIAL NOTES Part No 1150713 5 Perfecto 2 ™Series CAUTION “Caution: Statutory law can restrict this device to sale by or on order of a physician, or any other practitioner licensed by the law of the governmental agency in which he/she pr...
Page 6 - LABEL LOCATION
LABEL LOCATION Perfecto 2 ™Series 6 Part No 1150713 LABEL LOCATION Serial Number Label is located on the resonator intake assembly Specification Label is located on the back near the bottom Perfecto 2 ™ FOR OPERATING INSTRUCTIONS or ALARMS (See Operator’s Manual) DANGER - RISK OF FIRENO SMOKING - Ke...
Page 7 - SECTION 1—GENERAL GUIDELINES
SECTION 1—GENERAL GUIDELINES Part No 1150713 7 Perfecto 2 ™Series SECTION 1—GENERAL GUIDELINES In order to ensure the safe installation, assembly and operation of the Perfecto 2 concentrator these instructions MUST be followed. WARNING This section contains ...
Page 8 - Operating Information
SECTION 1—GENERAL GUIDELINES Perfecto 2 ™Series 8 Part No 1150713 Operating Information For optimum performance, Invacare recommends that each concentrator be on and running for a minimum of 30 minutes at a time. Shorter periods of operation may re...
Page 9 - Radio Frequency Interference
SECTION 1—GENERAL GUIDELINES Part No 1150713 9 Perfecto 2 ™Series Radio Frequency Interference This equipment has been tested and found to comply with EMC limits specified by IEC/EN 60601 ‐ 1 ‐ 2. These limits are designed to provide a reasonable prote...
Page 10 - SECTION 2—FEATURES
SECTION 2—FEATURES Perfecto 2 ™Series 10 Part No 1150713 SECTION 2—FEATURES Oxygen Outlet Flowmeter Oxygen Purity Indicator Lights / Fault and Power Indicator Lights Power Switch Circuit Breaker Elapsed Time Meter Cabinet Filter REAR VIEW *HF Outlet Fitting Power Cord *NOTE: This outlet fittin...
Page 11 - SECTION 3—HANDLING; Unpacking; Inspection
SECTION 3—HANDLING Part No 1150713 11 Perfecto 2 ™Series SECTION 3—HANDLING The concentrator should ALWAYS be kept in the upright position to prevent cabinet damage while being transported. If the concentrator is to be reshipped by common carrier, ...
Page 12 - SECTION 4—TECHNICAL DESCRIPTION
SECTION 4—TECHNICAL DESCRIPTION Perfecto 2 ™Series 12 Part No 1150713 SECTION 4—TECHNICAL DESCRIPTION The Invacare Perfecto 2 concentrator is used by patients with respiratory disorders who require supplemental oxygen. The device is not intended to sustain ...
Page 13 - SECTION 5—TYPICAL PRODUCT PARAMETERS
SECTION 5—TYPICAL PRODUCT PARAMETERS Part No 1150713 13 Perfecto 2 ™Series SECTION 5—TYPICAL PRODUCT PARAMETERS Alternating Current Type BF equipment Unit running Unit not running Attention - Consider Accompanying Documents DO NOT smoke Class II, Double Insulated Not Protected Electrical Requirement...
Page 17 - SECTION 6—OPERATING INSTRUCTIONS; SECTION 6—; OPERATING; Introduction
SECTION 6—OPERATING INSTRUCTIONS Part No 1150713 17 Perfecto 2 ™Series SECTION 6— OPERATING INSTRUCTIONS Introduction Your oxygen concentrator is intended for individual use. It is an electronically operated device that separates oxygen from room air. It pro...
Page 18 - Set Up; Filling the Humidifier
SECTION 6—OPERATING INSTRUCTIONS Perfecto 2 ™Series 18 Part No 1150713 Your oxygen concentrator will perform best when operated under the conditions outlined in the Typical Product Parameters on page 13. Usage in environments other than those describ...
Page 19 - Humidifer Bottle Adapter
SECTION 6—OPERATING INSTRUCTIONS Part No 1150713 19 Perfecto 2 ™Series 3. Insert a flathead screwdriver in the plate groove on the top edge of the filter access door and gently pry the filter access door off (FIGURE 6.2). 4. Pull up and remov...
Page 20 - Humidifier Compartment; Power Switch; For
SECTION 6—OPERATING INSTRUCTIONS Perfecto 2 ™Series 20 Part No 1150713 10. After assembly, ensure that oxygen is flowing through the cannula. FIGURE 6.3 Humidifier Compartment Power Switch NOTE: For this procedure, refer to FIGURE 6.4. 1. Press power switch to ...
Page 21 - Flowrate
SECTION 6—OPERATING INSTRUCTIONS Part No 1150713 21 Perfecto 2 ™Series Flowrate NOTE: For this procedure, refer to FIGURE 6.5. NOTE: Take care not to set the flow above RED ring. An oxygen flow greater than 5 L/min will decrease the oxygen co...
Page 22 - SensO
SECTION 6—OPERATING INSTRUCTIONS Perfecto 2 ™Series 22 Part No 1150713 SensO 2 Oxygen Purity Indicator - Model IRC5PO2AW This feature monitors the purity of oxygen generated by the oxygen concentrator. If purity falls below factory preset standards, indicator ...
Page 23 - Explanation of Indicator Lights - Model; IRC5PAW Model Indicator Light Explanation; Explanation of Indicator Lights - Model IRC5PAW
SECTION 6—OPERATING INSTRUCTIONS Part No 1150713 23 Perfecto 2 ™Series FIGURE 6.6 Explanation of Oxygen Purity Indicator Lights - Model IRC5PO2AW Explanation of Indicator Lights - Model IRC5PAW NOTE: For this procedure, refer to FIGURE 6.7. IRC5PAW Model Indicator Light Explanation RED...
Page 24 - SECTION 7—MAINTENANCE; Routine Maintenance; Cleaning the Cabinet Filter
SECTION 7—MAINTENANCE Perfecto 2 ™Series 24 Part No 1150713 SECTION 7—MAINTENANCE WARNING The Invacare concentrators are specifically designed to minimize routine preventive maintenance. Only qualified personnel should perform preventive maintenance on the con...
Page 25 - Cleaning the Cabinet
SECTION 7—MAINTENANCE Part No 1150713 25 Perfecto 2 ™Series 2. Clean the cabinet filter with a vacuum cleaner or wash in warm soapy water and rinse thoroughly. 3. Dry the filter thoroughly before reinstallation. FIGURE 7.1 Cleaning the Cabinet Filter Cleanin...
Page 26 - Model
SECTION 7—MAINTENANCE Perfecto 2 ™Series 26 Part No 1150713 PREVENTIVE MAINTENANCE RECORD Model No. IRC ______________ Serial No.________________ On Each Inspection *NOTE: Refer to Preventive Maintenance section of Service Manual. **NOTE: Model not available wit...
Page 27 - SECTION 8—TROUBLESHOOTING GUIDE
SECTION 8—TROUBLESHOOTING GUIDE Part No 1150713 27 Perfecto 2 ™Series SECTION 8—TROUBLESHOOTING GUIDE SYMPTOM: PROBABLE CAUSE: SOLUTION: Alarm: Main Power Loss: Short beeps, long pause 1. Power cord not plugged in. 1. Insert plug into outlet. Concentrator not operating,power switch On. 2. No power a...
Page 29 - SECTION 9—OPTIONAL ACCESSORIES
SECTION 9—OPTIONAL ACCESSORIES Part No 1150713 29 Perfecto 2 ™Series SECTION 9—OPTIONAL ACCESSORIES The following optional accessories are also available: • Standard Adult Nasal Cannula, 2.1 m (7 feet) ‐ M3120 • Standard Humidifier ‐ M5120 • PreciseRX™ Pediatric ...
Page 30 - RECYCLING INFORMATION
RECYCLING INFORMATION Perfecto 2 ™Series 30 Part No 1150713 RECYCLING INFORMATION This product has been supplied from an environmentally aware manufacturer that complies with the Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/CE. This p...
Page 31 - LIMITED WARRANTY
LIMITED WARRANTY Part No 1150713 31 Perfecto 2 ™Series LIMITED WARRANTY United Kingdom: Invacare Ltd, South Road, Bridgend Industrial Estate, UK ‐ Bridgend CF31 3PY Tel: (44) (0)1656 664 321, Fax: (44) (0)1656 667 532 [email protected] Ireland: Invacare Irel...