IDEAL 61-685 - Manual

IDEAL 61-685

IDEAL 61-685 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – Operating the Thermometer; Ratio of the distance from the measured object vs. the spot size; Emissivity; Emissivity is the ratio of infrared energy emitted from an; Emissivity Table
  • Page 4 – Made in China
  • Page 5 – Instrucciones de operación; Leyendas de las características
  • Page 6 – Operación del termómetro; entre la distancia y el tamaño de la mancha. El láser se usa sólo; Pantalla; Emisividad; El termómetro permite el ajuste de emisividad correspondi; Tabla de emisividad
  • Page 8 – Fabricado en China
  • Page 9 – Mode d’emploi; Légendes des caractéristiques; • Ne pas regarder directement le rayon laser – une lésion
  • Page 10 – Fonctionnement du thermomètre; objet et tirer sur la touche de détente Veiller à prendre en; Affichage; Rapport de la distance de l’objet mesuré vs la taille de spot de la; Emissivité; Table d’émissivité
  • Page 12 – SPÉCIFICATIONS; Remarque : Sous un champ électromagnétique de 3 V/m de; GARANTIE; d’achat. Durant cette période de garantie IDEAL INDUSTRIES,; Fabriqué en Chine
Loading the manual

Infrared (IR) Thermometer

Operating Instructions

#61-685

Instrument - Description

7

8

9

5

6

1

2

3

4

Feature Callouts

1. LCD display
2. Up key
3. Down key
4. Mode key
5. Thermocouple socket
6. Trigger key
7. Infrared lens
8. Class II laser
9. Battery cover

IMPORTANT SAFETY INFORMATION
Read

and

understand

all of the instructions and safety infor-

mation in these operating instructions before using this meter.
Use the meter only as specified in this manual; otherwise, the
protection provided by the meter may be impaired.
A

WARNING

statement identifies hazardous conditions

and actions that could cause bodily harm or death.

WARNINGS

To avoid possible electric shock, personal injury or death follow
these guidelines:

• Do not look directly into the laser beam – permanent eye

damage may result.

• Do not use a thermocouple on a live circuit.
• Do not use if meter appears damaged. Visually inspect the

meter to ensure case is not cracked.

• Do not use meter if it operates abnormally as protection

maybe impaired.

• Do not use without the battery and the battery case properly

installed.

• Do not attempt to repair this unit as it has no user-service

-

able parts.

• Replace battery if erratic operation occurs.
• Verify the thermometer is working properly by taking a

reading on a known measurement.

2

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Operating the Thermometer; Ratio of the distance from the measured object vs. the spot size; Emissivity; Emissivity is the ratio of infrared energy emitted from an; Emissivity Table

1 11 2 7 8 9 10 3 4 5 6 HOLD C F LOCK HI LOW Operating the Thermometer To measure temperature, aim the thermometer at an object and pull the trigger key. Be sure to consider the distance to spot size ratio. The laser is used for aiming only. Display 1. °F / °C Symbol - Fahrenheit / Celsius2. Hi alar...

Page 4 - Made in China

7 SPECIFICATIONS Item Non-contact Infrared Scan function Thermocouple Probe Scan function (K type; probe not included.) Measurement Range -76 to +932 °F (-60 to +500 °C) -83.2 to +1999°F (-64 to +1400°C) Operating Range 32 to +122°F (0 to +50°C) Accuracy [Tobj=59~95°F (15~35°C), Tamb=77°F (25°C)] 1....

Page 5 - Instrucciones de operación; Leyendas de las características

Termómetro infrarrojo (IR) Instrucciones de operación #61-685 Leyendas de las características 5 6 1 2 3 4 1. Pantalla LCD2. Tecla de subir3. Tecla de bajar4. Tecla de modo5. Zócalo de la termocupla6. Tecla de disparo7. Lente infrarroja8. Láser clase II9. Cubierta de las baterías INFORMACIÓN IMPORTAN...

Other IDEAL Models

All IDEAL Other