Page 2 - Cautions and Warnings; READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING; • To avoid possible electrical shock, before installing your fan,; Welc om e
2 45066-01 • 03/03/10 • Hunter Fan Company © 2010 Hunter Fan Company Your new Hunter ® ceiling fan is an addition to your home or office that will provide comfort and performance for many years. This installation and operation manual gives you complete instructions for installing and operating your ...
Page 3 - Step 1 - Choose the Fan Site; Choose a fan site where:; Checklist for Existing Fan Site; Pre parin g th e Fan Sit e
3 45066-01 • 03/03/10 • Hunter Fan Company 7’ Minimum Blades to Floor 8’ Minimum Ceiling Height 30” From Wall or Nearest Obstruction Step 1 - Choose the Fan Site Proper ceiling fan location and attachment to the building structure are essential for safety, reliable operation, maximum efficiency, and...
Page 4 - Step 2 - Cut the Ceiling Hole; • Installing the
4 45066-01 • 03/03/10 • Hunter Fan Company Pre parin g th e Fan Sit e (c ontinu ed) CAUTION: All wiring must be in accordance with national and local electrical codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician. Steps 2 – 3 Step 4 Step 5 Step 2 - Cut the Ceiling ...
Page 5 - Inst al ler’s Choice and O ptional Ac ce ss orie s; Understanding Mounting and Installer’s Choice; To
5 45066-01 • 03/03/10 • Hunter Fan Company Inst al ler’s Choice and O ptional Ac ce ss orie s Understanding Mounting and Installer’s Choice ® Hunter’s patented 3-position mounting system provides you maximum installation flexibility and ease. You can install your Hunter fan in one of three ways, dep...
Page 6 - To install a ceiling fan, be sure you can do the following:; Gathering the Tools; You will need the following tools for installing the fan:; Checking Your Fan Parts; Installing Multiple Fans?; • Gettin g R eady
6 45066-01 • 03/03/10 • Hunter Fan Company To install a ceiling fan, be sure you can do the following: • Locate the ceiling joist or other suitable support in ceiling.• Drill holes for and install wood screws.• Identify and connect electrical wires.• Lift 40 pounds. If you need help installing the f...
Page 7 - ANGLED; OR; • Inst al lin g th e Han ger Bracket
7 45066-01 • 03/03/10 • Hunter Fan Company 2-1. Drill two pilot holes into the wood support structure through the outermost holes in the outlet box. The pilot holes should be 9/64” in diameter. Note: Your fan comes with four pre-installed neoprene noise isolators. 2-2. Thread the lead wires from the...
Page 8 - -1. To assemble the housing to the hanger adapter, align the three; • A ssemblin g th e Top Housin g
8 45066-01 • 03/03/10 • Hunter Fan Company 3-1. To assemble the housing to the hanger adapter, align the three raised tabs on the hanger adapter with the three narrow notches in the top housing. Make certain the housing sits flat on the adapter. 3-2. Install three (3) assembly screws and washers and...
Page 9 - • Setting the remote wall control and receiver.; • A ssemblin g and Han g in g th e Fan
9 45066-01 • 03/03/10 • Hunter Fan Company You can assemble your fan for standard or angled mounting as shown in steps 4-1 – 4-3. For low profile mounting (ceilings less than 8 feet high), go to steps 4-6 – 4-9 on the next page. 4-1. To assemble fan to hang down from a flat or angled ceiling, place ...
Page 10 - • A ssemblin g and Han g in g th e Fan (Low Prof i le O nly); standard
10 45066-01 • 03/03/10 • Hunter Fan Company 4 • A ssemblin g and Han g in g th e Fan (Low Prof i le O nly) You can assemble your fan for standard or angled mounting as shown in steps 4-1 – 4-3 on the previous page. For low profile mounting (ceilings less than 8 feet high), see steps 4-6 – 4-10 on th...
Page 11 - Setting DIP switches; • Settin g th e R emot e Wal l Control and R e ceiver
11 45066-01 • 03/03/10 • Hunter Fan Company 5-1. Press inward on each side of the wall control to remove the face cover. Set the dip switches to match the dip switches in the receiver. IMPORTANT! Before you change the DIP switch settings, make sure the battery is not connected to the transmitter. Ch...
Page 12 - • Wirin g th e Fan
12 45066-01 • 03/03/10 • Hunter Fan Company All wiring must be in accordance with national and local electrical codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician. 6-1. Before attempting installation, make sure the power is still off.6-2. To connect the wires, hol...
Page 13 - Should you need to remove the canopy; Twist canopy trim ring counter; • Inst al lin g th e C anopy and C anopy Trim Rin g
13 45066-01 • 03/03/10 • Hunter Fan Company 7-1. Partially install two canopy screws (about 2 full turns) in the hanger bracket. 7-2. Raise the canopy over the hanger bracket. Align partially installed screws with key slots in canopy. 7-3. Twist canopy clockwise to secure.7-4. Install third & fo...
Page 14 - -3. For each blade, insert one blade iron armature screw through the; • A ssemblin g th e Bl ade s
14 45066-01 • 03/03/10 • Hunter Fan Company Steps 8-2 – 8-3 Hunter fans use several styles of fan blade irons (brackets that hold the blade to the fan).8-1. Install the grommets into the blades by hand. 8-2. Place each blade between a blade iron and medallion. Install three blade assembly screws to ...
Page 15 - Your Hunter fan comes with an integrated light fixture assembly.; assembly screws into the light kit mounting plate.; • Completin g Your Inst al l ation With a Li g ht Fi xture
15 45066-01 • 03/03/10 • Hunter Fan Company Your Hunter fan comes with an integrated light fixture assembly. WARNING: Use only the light fixture supplied with this fan model. 9-1. To attach the light kit top housing, partially install two housing assembly screws into the light kit mounting plate. 9-...
Page 16 - • Completin g Your Inst al l ation With a Li g ht Fi xture (Continu ed)
16 45066-01 • 03/03/10 • Hunter Fan Company Light Kit Plug Connector Housing Assembly Screw Housing Assembly Screw Plug Connector Detail Steps 9-5 – 9-6 9-5. To attach the light kit, connect the upper plug connector from the motor to the lower plug connector in the light kit. Note: Both plug connect...
Page 17 - Installing the Glass Bowl; -8. Lift the glass bowl up to the light kit top
17 45066-01 • 03/03/10 • Hunter Fan Company Installing the Glass Bowl 9-7. First install B10 candelabra bulbs (60 Watt Maximum) into the sockets. 9-8. Lift the glass bowl up to the light kit top housing. Align the three tabs in the glass bowl with the three slots in the light kit top housing. 9-9. R...
Page 18 - 0 • Inst al lin g th e Wal l Control
18 45066-01 • 03/03/10 • Hunter Fan Company 10-1. Disconnect the existing switch and remove it from the electrical box. Set the screws aside for reuse. 10-2. Connect each wire from the wall to a lead from the control. Use 2 of the wire connectors supplied to make the connections. Refer to Figure 1. ...
Page 19 - 1 • O p eratin g th e R emot e Control and Mountin g th e Hol der
19 45066-01 • 03/03/10 • Hunter Fan Company 11-1. The wall control has individual buttons for setting fan speed and light intensity. Refer to the figure on the right. Note: For best operation, start the fan by pressing high, then select your desired speed. 11-2. The light button turns the light. Pus...
Page 20 - To Change Airflow Direction; 2 • O p eratin g and Cleanin g Your C ei lin g Fan
20 45066-01 • 03/03/10 • Hunter Fan Company 12-1. Ceiling fans work best by blowing air downward (counterclockwise blade rotation) in warm weather to cool the room with a direct breeze. In cold weather, having the fan draw air upward (clockwise blade rotation) will distribute the warmer air trapped ...
Page 21 - Problem: Lights dim when turned on or do not turn on; Check to make sure wattage of light bulbs installed match the; Problem: If the light on this fan shuts off suddenly.; 3 • Trouble sho otin g
21 45066-01 • 03/03/10 • Hunter Fan Company Problem: Nothing happens; fan does not move. 1. Turn power on, replace fuse, or reset breaker.2. Loosen canopy, check all connections according to the wiring the fan section. 3. Check the plug connection in the light fixture.4. Remove the shipping bumpers....