Page 2 - MAINTENANCE
2 DISCONNECT ELECTRIC POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT W a r n i n g TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING: 1. For general ventilating use only. Do not use for ventilat- ing hazardous or explosive materials. 2. To avoid motor bearing damag...
Page 3 - Before Installation; Check all the parts.
E F G H I J K L x4 * * * NOTE: Strain relief cable connector must be installed. Not Included. A B C 95047-04-000 75864-01-000 03242-07-133 95261-01-000 74508-03-133 96382-01-262 75184-01-133 96384-01-000 M 75730-01-214 Extra Screws x2 D 3/8” Cable Connector x2 3 1 Turn off the power source. Tools Ne...
Page 5 - New Construction; Choose Installation Option
9 E Pop out the first wiring access slug. Use second if needed. Insert the strain relief (not included) into the housing and secure with washer. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. New Construction 5 10 B C A11 E 5/81/2 5/81/2 A12...
Page 7 - Go to step
A19 I Secure the motor by tightening the 2 screws. A20 Turn on the power source. 7 Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. 00000000 A17 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the moto...
Page 8 - EXISTING FAN; Existing Construction
8 EXISTING FAN B11 E B12 Existing Construction B13 2 1 B14 Route wires through strain relief . Remove an existing fan and check to make sure the open- ing is large enough to accommodate the new motor hous- ing (7 1/4”x 7 3/4”). Move the housing into position above the ceiling Attach existing ducting...
Page 10 - Attaching the Grille
10 ON OFF B22 B23 C1 Go to step on page 10 to attach grille. B21 Test the motor. If the motor does not run, check the plug connection. Turn on the power source. Attaching the Grille Remove the thumbscrews. Connect wiring harness. DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS. K C1 C2 J 41...
Page 12 - Trouble Shooting
12 Trouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker. • Check all plug connections to be sure they a...
Page 13 - Warranty
13 41945-01 3/29/2006 41945-01 3/29/2006 Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fix...
Page 15 - DESDE; Ventilador para baño Sand Dollar; LEA y CONSERVE ESTAS INSTRUCCIONES
DESDE Ventilador para baño Sand Dollar 82003 con luz LEA y CONSERVE ESTAS INSTRUCCIONES 41945-02 3/29/2006 G u í a d e i n s t a l a c i ó n E s p a ñ o l 15 05-HF-021-Sp_3.29.06.indd 15 3/29/06 7:16:41 PM
Page 16 - A D V E R T E N C I A; ManteniMiento
16 41945-02 3/29/2006 41945-02 3/29/2006 DESCONECTE LA ALIMENTACIÓN ELÉCTRICA Y CIERRE EL PANEL DE SERVICIO ANTES DE DAR MANTENIMIENTO A LA UNIDAD tc. Retire las cubiertas de las puntas de tornillo precargadas. A D V E R T E N C I A PARA REDUCIR EL RIESGO DE DESCARGA ELÉCTRICA O LESIONES, OBSERVE LO...
Page 17 - Antes de la instalación; Verifique todos los
E F G H I J K L x4 * * * NOTA: Debe estar instalado el manguito de alivio de tensión del cable. No incluido. A B C 95047-04-000 75864-01-000 03242-07-133 95261-01-000 74508-03-133 96382-01-262 75184-01-133 96384-01-000 M 75730-01-214 Tornillos adicionales x2 D Conector de cable de 3/8” x2 17 1 2 E I...
Page 19 - Construcción nueva; Escoja la opción de instalación
9 E 19 10 B C A11 E 5/81/2 5/81/2 A12 Retire el primer tapón metálico de acceso del cableado. Utilice el segundo si es necesario. Inserte el manguito de alivio de tensión (no se incluye) en la caja y sujételo firmemente con una arandela. Ubique la correcta marca de profundidad en el borde inferior d...
Page 21 - Vaya al paso
A19 I A20 21 00000000 A17 00000000 H A18 ENCENDIDO APAGADO A21 A22 C1 Vaya al paso en la página 24 para fijar la rejilla. Asegure el motor apretando los 2 tornillos. Encienda la fuente de alimentación. Conecte el mazo de cables. NO PERMITA QUE EL MOTOR CUELGUE DEL MAZO DE CABLES. Vuelva a instalar e...
Page 22 - VENTILADOR EXISTENTE; Construcción existente
22 VENTILADOR EXISTENTE B11 E B12 B13 2 1 B14 E B15 Construcción existente Tienda los cables a través del manguito de alivio de tension. Retire el ventilador existente y asegúrese que la abertura sea suficientemente grande para acomodar el alojamiento del motor nuevo (7 1/4” x 7 3/4”). Mueva el aloj...
Page 24 - Fijación de la rejilla
24 ENCENDIDO APAGADO B22 B23 C1 Vaya al paso en la página 24 para fijar la rejilla. B21 Fijación de la rejilla Retire los tornillos de mano. Conecte el mazo de cables. NO PERMITA QUE EL MOTOR CUELGUE DEL MAZO DE CABLES. K C1 C2 J Pruebe el motor. Si el motor no funciona, verifique la conexión del en...
Page 26 - Solución de problemas
26 Solución de problemas problema: El ventilador no está operando. Solución: • Los ventiladores de baño Hunter son muy silenciosos. Para confirmar que el ventilador esté funcionando, coloque su mano cerca de los conductos de ventilación para sentir el movimiento del aire. • Encienda la alimentación ...
Page 27 - Garantía
27 41945-02 3/29/2006 41945-02 3/29/2006 Garantía Hunter Fan Company Extractor de aire para baño GARANTÍA LIMITADA Hunter Fan Company establece la siguiente garantía limitada al usuario o comprador original de este Extractor de aire para baño Hunter: Si alguna pieza de su Extractor de aire para baño...