- Page 2 – PERFORMANCE SPECIFICATIONS; Single Phase Motor Data 60HZ Chart C; †Thermal overload protector - automatic reset
- Page 3 – Three Phase Motor Data Chart D; HP, 3 Phase motor operable on 60Hz only.; Material; Component; Chart F
- Page 4 – General Safety Information; WILL; HANDLING
- Page 5 – Mount pump in correct position or pump failure will result.; Figure 2 - No Air Pockets in Inlet Pipe; Figure 4A; Installation; Support pump and; PRESSURE BOOST SYSTEMS; Do not use a globe
- Page 6 – A pressure gauge installed in the; Install a pressure; Figure 6; A contained air pressure tank and pressure switch is required to; Pump used to boost incoming city pressure (automatic operation).; Clean all filters and strainers on a regular schedule.; Figure 7
- Page 7 – Proper rotation of; WIRING; Ground the pump permanently using; Do not ground to; Check local and/or; Make certain that; Figure 8; Dual voltage motors, change the red and
- Page 8 – Specific Wiring Procedure; Replace rear access cover before starting; not supplied; Never examine, make wiring changes or; Operation; Unit must be full of fluid before operat-; VALVES; CONNECTION FOR 3 PHASE, 9 LEADS. IF YOUR 3 PHASE; Figure 11 - Wiring Diagram for Three Phase Motors
- Page 9 – Do not go over recommended maximum; Maintenance; Disconnect power supply and depressur-
- Page 10 – Figure 13 - Remove Mechanical Seal; Seal
- Page 11 – Troubleshooting Chart; Symptom
- Page 13 – PRESSURE BOOSTER PUMP REPAIR PARTS; (For Pricing Refer To Repair Parts Price List)
1
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com
Description
Pressure booster pumps increase water pressure from city mains or private water sys-
tems. Applications include providing high water pressure for washing buildings, dairy
walls or floors, hog parlors, poultry houses, rinsing or spray cooling equipment, lawn
sprinkling and insecticide spraying. Stainless steel models can handle salt-water and
contaminated water in reverse osmosis filter and other aggressive water applications.
Single-phase models are equipped with a capacitor start, thermal protected motor.
Three-phase models require separate overload protection.
Unpacking
When unpacking the unit, inspect care-
fully for any damage that may have
occurred during transit.
NOTE
: Use pump with clear water
only.
132934
Pressure Booster Pumps
Operating Instructions & Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in per-
sonal injury and/or property damage! Retain instructions for future reference.
FW0154
0907
Supersedes
0306
IL0391
Figure 1
Inlet I
Discharge J
G
H
A
C
F
D
B
E
60 Hz Motor Driven Pump Dimensions (See Figure 1) •
Chart A
Stainless
Steel Fitted
Powder-Coated
Cast Iron Fitted
Cast Iron
Fitted
Dimensions In Inches
Lbs. Ship
Wt.
A
B
C
D
E
F
G
H
I
J
PB0508S031
PB0512S051
PB0516S071
PB0712S071
PB1014S101
PB1016S151
PB1914S201
PB2711S201
PB3506S201
PB2714S301
PB3508S301
-
-
-
-
PB0508C031
PB0512C051
PB0516C071
PB0712C071
PB1014C101
PB1016C151
PB1914C201
PB2711C201
PB3506C201
PB2714C301
PB3508C301
-
-
-
-
PB0508A031†
PB0512A051†
PB0516A071
PB0712A071
PB1014A101
PB1016A151
PB1914A201
PB2711A201
PB3506A201
PB2714A301
PB3508A301
PB5504A201
PB5506A301
PB8504A201
PB8505A301
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
10-3/16
13-3/8
16-1/2
13-3/8
16-5/16
17-5/8
18-1/8
15-3/8
13-15/16
18-1/2
17-1/8
13-3/4
18-1/16
16-1/2
19-5/16
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
19-15/16
23-3/8
27
23-7/8
27-1/4
29-3/16
29-11/16
27-1/2
25-7/8
30-9/16
29-3/16
25-15/16
30-3/16
28-5/8
31-1/2
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
1-7/16
1-7/16
1-7/16
1-7/16
1-7/16
1-7/16
1-7/16
1-7/16
1-7/16
1-7/16
1-7/16
2-1/8
2-1/8
2-1/8
2-1/8
3/4
3/4
3/4
3/4
3/4
3/4
3/4
1
1
1
1
2
2
2
2
3/4
3/4
3/4
3/4
3/4
3/4
3/4
1
1
1
1
2
2
2
2
35
38
43
42
48
51
51
52
51
54
53
57
57
58
58
50 Hz Motor Driven Pump Dimensions (See Figure 1) •58
PB0508Y031
PB0514Y051
PB0714Y071
PB1020Y101
PB1023Y101
PB2717Y201
-
PB1021Y101
PB1920Y151
-
-
-
-
-
PB1023Z101
-
-
-
-
PB1922Z201
PB0508X031
PB0514X051
PB0714X071
PB1020X101
PB1023X101
-
PB3508X151
-
-
-
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
3-3/4
10-3/16
14-7/16
14-15/16
21-11/16
24-3/8
21-5/16
16-13/16
22-1/2
24-1/16
26-1/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
3-7/8
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
20-3/16
25-7/16
25-15/16
33-5/16
36
33-7/16
29-11/16
34-3/16
34-3/8
37-3/16
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
7-3/8
1-7/16
1-7/16
1-7/16
1-7/16
1-7/16
1-7/16
1-7/16
1-7/16
1-7/16
1-7/16
3/4
3/4
3/4
3/4
3/4
1
1
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
1
1
3/4
3/4
3/4
34
41
47
53
55
56
52
54
56
59
(*) NOTE: Figure 1, holes in mounting base are open slotted 3/8” wide x 1/2” long; dimension A & B are centerline from these
open slotted holes. These holes are suitable for 1/4 to 3/8” bolts.
Dimensions also apply to three phase models.
(
†) Equipped with carrying handle. 132079 handle available as an option on other models. Add 1-3/8” to “G” if handle is included.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com PERFORMANCE SPECIFICATIONS PRESSURE ADDED - PSI 10 20 40 60 80 100 120 140 160 180 200 Max. Press. PSI Suction Pipe Tap NPT Disch. Pipe Tap NPT Stainless Steel Fitted Powder- Coated Cast Iron Fitted Cas...
3 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com Three Phase Motor Data Chart D Three Phase† 60/50 Hz 3450/2850 RPM Capacitor Start HP Motor Voltage Factory Connected Motor Voltage Service Factor Motor Amps Locked Rotor Motor Amps Code Letter 230V 460...
4 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com General Safety Information Carefully read and follow all safety instructions in this manual and on pump. Keep safety labels in good condition. Replace missing or damaged safety labels. This is a SAFETY ...