A user manual for the Fire-Lite IPDACT system outlines its installation, connectivity, and programming requirements. The guide covers essential setup steps–including mounting hardware, power wiring, and cable connections–while emphasizing network and central-station compatibility. It also details configuration processes such as DHCP-based IP assignment, phone line management, and device registration via HyperTerminal or serial interfaces. Safety and proper polarity are highlighted throughout to ensure reliable operation.
Table of Contents:
- Page 1 – System Installation Components and Parts List
- Page 2 – Power Requirements and Mounting Guidance
- Page 3 – IPDACT Mounting Procedure
- Page 4 – Cable Interconnection Procedures
- Page 5 – Module Installation within Enclosures
- Page 6 – IPDACT Module Installation in Power Supply
- Page 7 – Module Programming and Defaults
- Page 8 – HyperTerminal Connection Configuration
- Page 9 – Serial Port and Password Setup
- Page 10 – Device Configuration Menu
- Page 11 – IP Address Configuration via Quick Install
- Page 12 – Device Registration and Reset Procedures
- Page 13 – Communication and Network Settings
- Page 14 – IP Address Behavior and Monitoring
- Page 15 – Viewing Active IP Configuration
5/19/2008
1 of 15
Application Note:
Fire-Lite IPDACT Setup for Installing Dealers
These pictorial instructions should be used in conjunction with the formal
PID (Product Installation Document) included with the IPBRKT or IPENC as
well as the instructions included with the IPDACT. Please Read all
documentation prior to performing any installation or programming.
Installation Instructions for use with HyperTerminal™ and serial port
Parts List
Part Numbers
Description
IPDACT
Internet Communicator-Contact ID only.
Requires compatible FL panel equipped
with on-board or optional DACT. Requires
300mA aux non-reset able power from
FACP. Includes cable from panel primary
telco port to IPDACT.
IPBRKT
Bracket for mounting IPDACT inside MS-
9200UDLS common enclosure or in
optional HPP-300ULX power supply
IPSPLT
Splitter for dual phone lines to IPDACT
input cable.
ALMSC119
RJ45-DB9F PC serial port programming
cable for IPDACT.
IPENC
Optional cabinet for mounting IPDACT next
to compatible Fire-Lite FACP. Use when
connecting to older non common enclosure
panels such as MS-9200UD or MS-9600.
Includes IPBRKT mounting bracket already
installed.
HP300ULX
Optional UL listed Fire Aux power supply for
mounting IPDACT next to compatible Fire
Panel when additional power is required for
IPDACT.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Honeywell
- Model
- Smoke Alarm
- Document type
- Manual
- Language(s)
- English
- Pages
- 15
- File size
- 560 KB
- Format
Other Manuals for Honeywell Smoke Alarm
Summary
Installation instructions and a parts list detailing required components such as the IPDACT unit, mounting brackets, splitters, programming cables, cabinets, and power supplies.
Power and connectivity requirements for the IPDACT device, programming information from the central station checklist, and instructions for mounting the device within a common enclosure.
Instructions for mounting the IPDACT device onto the IPBRKT using plastic standoffs and connecting to a 24 VDC power source, including polarity warnings.