HE225A,B

BypassFlow-ThroughHumidifier

READ AND SAVE THESE INSTRUCTIONS

APPLICATION

The Enviracaire

Elite

TM

HE225A,B Bypass Flow-Through

Humidifier

uses the warm air furnace blower to provide humidification

for the whole

humidifier pad assembly. See Fig. 2.

house. The HE225A,B works with virtually any Honeywell humidity
control, but for optimal performance,

use with the Honeywell Perfect

i

Climate Comfort Center

TM

control.

INSTALLATION

r-

injury or equipment

damage.

any air conditioning

or electrical

m

CAUTION

Freezing Water and High Water or Static Pressure Hazard.
Can cause water damage or permanent equipment

damage.

•

The humidifier must be located where the ambient
temperature

is above 32°F (0°C) and below 160°F (71 °C).

•

Be sure supply plenum static pressure is no greater than
0.3 in. w.c. and water pressure is no greater than 125 psi.

IMPORTANT

To assure optimal product performance,

be sure the template

is level before marking.

1. Determine the best location for the humidifier and draw a level line

on the plenum. See Fig. 1.

2. Tape this piece of paper in position as your template and trace

around the template.

3.

Remove the template and carefully cut the rectangular opening.

4.

Disassemble the humidifier. Remove the cover and take out the

12

Fig. 1. Typical humidifier installation

locations.

NOTE:

Sidewalls are interchangeable

for either left or right

bypass installation. To change direction, remove the
screws holding each sidewall, switch sidewall locations
and reinstall the screws.

IMPORTANT

Mount the humidifier at least 3 in. (76 mm) above the furnace

jacket to allow adequate space for the solenoid valve and drain

line. Check that there is adequate space above the humidifier
to remove and install the humidifier cove_ Do not install on a

furnace jacket.

5. Position the humidifier housing in the opening (be sure it is level),

so the locking tabs are in place on the lower sheet metal edge of
the opening.

6. Secure the humidifier housing to the opening at the top and

bottom using sheet metal screws.

.J

n

I-

® U.S. Registered Trademark

Copyright © 2003 Honeywell

International

Inc.

•

All Rights Reserved

TEMPLATE

69-1425EF-1

IMPORTANT

The damper is specifically designed with snap featues for use

specifically with Honeywell humidifiers. It is not intended for
use in any other application.

7. To install the damper:

a.

Insert the damper into the humidifier with the selector knob
aligned with the forward-facing

hole in the humidifier collar.

b.

Twist the damper until it snaps into place.

WATER

IUMIDIFIER

PAD ASSEMBLY

B_PASS

SUMMER

SHUTOFF

DAMPER

M19791

Fig. 2. Humidifier

components.

8. Locate the other plenum and cut an opening for a 6 in. (152 mm)

collar.

9. Install the 6 in. (152 mm) collar.

10.

Install a 6 in. (152 mm) diameter duct from the collar to the
humidifier.

NOTE:

Some installations

require a 90 ° elbow attachment

to the

collar.

11. Seal the duct connections with duct tape.

NOTE:

To avoid sagging and stress on the humidifier, add
support when ducting is longer than 4 ft (120 cm).

12. Reinstall the humidifier pad assembly in the humidifier housing.

NOTE:

Be sure the water feed tube is not pinched or kinked.

13. Hinge the cover in place and secure with the thumbscrew

located

at the bottom of the cover.

WIRING

CAUTION

Hazardous

Voltage.

Can cause personal injury or equipment

damage.

•

Disconnect

power supply before installing or servicing.

•

On multispeed blower applications,

do not wire the high

voltage side of the transformer

to the same power source that

services the furnace blower or the transformer

may burn out

prematurely.

All wiring must comply with applicable local codes, ordinances and
regulations.

1. Mount the transformer

in a convenient location.

IMPORTANT

Install transformer

on the outside of a grounded metal junction

box using only a 7/8 in. (22 mm) knockout hole. Place mounting
tabs into the knockout hole and firmly tighten the locking screw
Field wiring connections

and grounding

means for the

transformer and enclosure shall be in accordance

with the

National Electrical Code (NEC) and the Canadian Electrical

Code (CEC).

2. Connect wires to the 120V side of the transformer.

For humidity control wiring

connections:

1. Wire the humidifier solenoid valve, current sensing relay or sail

switch, humidity control and transformer.

Refer to the humidity

control installation instructions

for mounting and wiring

information.

IMPORTANT

•

Forproper

operation, the humidifier must be energized during

blower motor cycles.

•

Current sensing relay or sail switch is not needed with the

Automatic

Humidity Control.

NOTE:

Select models of fan centers include humidifier taps so the
current sensing relay or sail switch are not needed.

69-1425EF

PLUMBINGSADDLE VALVE

Hot or cold water, either hard or softened, can be used in the humidifier.

1. Use the self-piercing

saddle valve (included) to tap into the water

supply line at an appropriate

location.

WARNING

Chemical

Hazard.

Can cause personal injury or equipment

damage.

Do not use any line connected to an air conditioner.

IMPORTANT

•

The saddle valve is not designed to be used to regulate water

flow. The valve is either open or closed.

•

To prevent debris from clogging the solenoid in-line filter, be

sure to install the saddle valve handle pointing toward the
ceiling.

NOTE:

Lightly clean the copper tubing ends with fine sandpaper
before making any connections.

Use 1/4 in. O.D. copper tubing and connect the saddle valve to the
inlet side of the solenoid valve.

a.

Place the brass compression

nut over the copper tubing.

b.

Slide the brass ferrule over the tubing.

NOTE:

Do not over-tighten the compression

nut. Moderate

tightness will prevent leaking.

c.

Insert the tubing into the solenoid valve fitting and support
the valve while tightening the compression

nut.

NOTE:

Slope drain tube downward for correct drainage.

3. Connect a 1/2 in. drain tube to the humidifier drain fitting and run

to a suitable drain.

CHECKOUT

1. Open the saddle valve.

NOTE:

The furnace blower must be on for the humidifier to

operate.

2. Set the thermostat setpoint 10°F (6°C) above the room

temperature.

3. Set the Convertible

Humidity Control to a high humidity setting, or

place the H1008A Automatic Humidity Control in the test position.

4. Observe the water running out of the drain line to be sure the

humidifier is working properly.

5. Check for leaks.
6. Reset the thermostat and Convertible

Humidity Control to a

comfortable setting, or the Automatic

Humidity Control to the

desired frost factor setting.

Honeywell

Automation

and Control

Solutions

Honeywell

International

Inc.

Honeywell

Limited-Honeywell

Limit@

1985 Douglas

Drive

North

35 Dynamic

Drive

Golden

Valley,

MN 55422

Scarborough,

Ontario

MIV

429

69-1425EF-1

G.H.

10-03

Printed

in U.S.A. on recycled

paper containing

at least 10%

post=consumer

paper fibers.

,r|

www.honeywell.com/yourhome/

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Honeywell
Model
HE265A1007
Document type
Installation Manual
Language(s)
English
Pages
1
File size
250.8 KB
Format
PDF

Other Manuals for Honeywell HE265A1007

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.