INSTALLATION ADDENDUM
69-2576-01
Wiring Configuration
ADVANCED MODELS (HE150/HE250/HE300)
Fig. 1. Wiring H8908 to humidify only with a call for heat or fan.
Fig. 2. Wiring TrueIAQ, VisionPRO IAQ, or Prestige, using the intelligent control to program humidity calls with heat,
cool, or on demand.
HE150 OR HE250
DIP SWITCH SETTING
RESET POWER AFTER
ANY DIP SWITCH CHANGES
HE300
H8908
10
OFF
ON
20
30
40
50
60
M29938A
POWER IN
G OR W
C
OR
AIR PROVING
DEVICE
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
CONNECT G TO HUMIDIFY WHEN THERE IS A FAN CALL.
CONNECT W TO HUMIDIFY WHEN THERE IS A HEAT CALL.
NEVER CONNECT BOTH. CONNECT C WHEN USING G OR W.
USE AIR PROVING DEVICE INSTEAD OF THE G/W CONNECTION
TO HUMIDIFY ANY TIME THE FAN IS OPERATING.
1
1
2
3
3
2
HE300 USES A LINE CORD PLUG.
CONNECT G TO HUMIDIFY WHEN THERE IS A FAN CALL.
CONNECT W TO HUMIDIFY WHEN THERE IS A HEAT CALL.
NEVER CONNECT BOTH. CONNECT C WHEN USING G OR W.
USE AIR PROVING DEVICE INSTEAD OF THE G/W CONNECTION
TO HUMIDIFY ANY TIME THE FAN IS OPERATING.
1
3
2
H8908
10
OFF
ON
20
30
40
50
60
POWER IN
G OR W
C
AIR PROVING
DEVICE
1
2
3
OR
M29939A
FROM
HUMIDITY
CONTROL
HE150 OR HE250
DIP SWITCH SETTING
RESET POWER AFTER
ANY DIP SWITCH CHANGES
HE300
POWER IN
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
1
1
HE300 USES A LINE CORD PLUG.
1
POWER IN
FROM
HUMIDITY
CONTROL
1
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
WIRING CONFIGURATION 69-2576—01 2 Fig. 3. Wiring to force the HVAC system fan on whenever humidity is needed (on demand). Fig. 4. Wiring to force fan on and prove airflow in the duct. M29940A G (FURNACE) G (THERMOSTAT) ONLY NEEDED IF SYSTEM’S THERMOSTAT DOES NOT ISOLATE Y FROM G. IF NEEDED, BREAK TH...
WIRING CONFIGURATION 3 69-2576—01 BASIC MODELS (HE100/HE200) Fig. 5. Wiring H8908 with fan interlock. Fig. 6. Wiring H8908 with 2-speed fan motor. H8908 1 2 HUMIDIFIER TRANSFORMER FURNACE FAN MOTOR FAN CONTROL L1 (HOT) L2 M29945A POWER SUPPLY 10 OFF ON 20 30 40 50 60 1 2 PROVIDE DISCONNECT MEANS AND...
WIRING CONFIGURATION Automation and Control Solutions Honeywell International Inc.1985 Douglas Drive NorthGolden Valley, MN 55422 Honeywell Limited-Honeywell Limitée35 Dynamic DriveToronto, Ontario M1V 4Z9customer.honeywell.com ® U.S. Registered Trademark© 2011 Honeywell International Inc.69-2576—01...