  • Page 2 – Label wires and remove old wallplate
  • Page 3 – Mount thermostat base; Existing wires Connect to:; Connect wires
  • Page 4 – Finish installation; Set cycle rate switches
  • Page 5 – Operation; Temperature setting; -year limited warranty; Temperature
  • Page 6 – Owner’s Manual; Vérifier le contenu de; Retrait de l'ancien thermostat
  • Page 7 – Étiquetage des fils et retrait de l'ancienne plaque murale; Installation de la plaque de raccordement
  • Page 8 – Installation de la plaque murale et de la plaque de raccordement; Les étiquettes ne; Fils existants Raccorder à :; Raccordement
  • Page 9 – Réglages du nombre de cycles; Montage du thermostat
  • Page 10 – Garantie limitée de un an; Sélecteur du ventilateur; Réglage de la; Fonctionnement
  • Page 11 – Lista de comprobación previa a la instalación; Remueva su viejo termostato
  • Page 12 – Rotule los cables y retire la vieja placa de montaje; Repérez la position de montage
  • Page 13 – Instalación de placa de montaje; Cableado CT87N; Cableado CT87K; ¿Los rótulos no coinciden?; Cables existentes Conecte a:; Conecte los cables
  • Page 14 – Finalice la instalación; Ajuste de funcionamiento del ventilador (CT87N)
  • Page 15 – Interruptor del ventilador; Interruptor del sistema; Instrucciones de funcionamiento; Ajuste de temperatura; Garantía limitada de un año
  • Page 16 – Honeywell International Inc.; Automation and Control Solutions; Honeywell Limited-Honeywell Limitée; For assistance with this product please visit
Loading the manual

Owner’s Manual

English: Page 1

Mode d’emploi

Français : Page 6

Manual de Uso

Español: Página 11

CT87N/CT87K

The Round

®

® U.S. Registered Trademark. U.S. Patents 7,159,789;

7,159,790; 7,476,988 and other patents pending.

Copyright © 2009, Honeywell International Inc.

All rights reserved.

69-1959EFS-02

The Round

®

1.

CAUTION

TURN OFF POWER to system at the furnace, or at the fuse/circuit breaker

panel before you begin.

2. Remove cover and thermostat, but leave wallplate with wires attached.

MERCURY NOTICE

If your old thermostat contains

mercury, contact your local waste

management authority for proper

disposal instructions.

Is there a sealed tube containing

mercury? If so, see mercury notice

below.

Leave wallplate in place.

Old thermostat

Cover

Check package contents:

• Thermostat

• Coverplate

• Wall anchors & screws (2 each)

• Wire labels

Before you begin, make sure

you have:

• No. 2 Phillips & small pocket

screwdrivers

• Hammer

• Level (optional)

• Pencil

• Drill and bit (3/16” for drywall, 7/32”

for plaster)

Getting started

Remove your old thermostat

CT87K

(24 Vac heating systems) •

CT87N

(24 Vac heating and cooling systems)

This thermostat contains a Lithium battery which

may contain Perchlorate material.

Perchlorate Material—special handling may apply,

See www.dtsc.ca.gov/hazardouswaste/perchlorate

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Honeywell CT87K

Summary

Page 2 - Label wires and remove old wallplate

CT87N/CT87K • Owner's Manual 69-1959EFS—02 2 Wrap supplied labels securely around each wire. Do not let wires fall into wall opening! IGNORE WIRE COLORS: Use only letter designations to identify wire types. For CT87N : If your old thermostat has 7 or more wires ( not counting terminals C or C1 ), yo...

Page 3 - Mount thermostat base; Existing wires Connect to:; Connect wires

English: Page 1 • Français : Page 6 • Español: Página 11 3 69-1959EFS—02 Wiring CT87N [1] If wires will be connected to both R and Rc terminals, remove the metal jumper. [2] Do not connect both O and B if you have a heat pump. Connect only the O wire. Wrap B wire with electrical tape and do not use....

Page 4 - Finish installation; Set cycle rate switches

CT87N/CT87K • Owner's Manual 69-1959EFS—02 4 1. Align the slots on the base with tabs on the thermostat, then push gently until the thermostat snaps into place. 2. Restore electrical power at the heating/ cooling system, or at the fuse/circuit- breaker panel. Move the switch to the proper setting fo...