- Page 2 – INSTALLATION; Installation Tips; CAUTION; Remote Sensor Wallplate Installation
- Page 3 – WIRING; OPERATION
- Page 4 – CHECKOUT
- Page 5 – NOTICE D'INSTALLATION; Capteur de température ambiante à; (À UTILISER AVEC LES THERMOSTATS VISIONPRO®); APPLICATION; CARACTÉRISTIQUES TECHNIQUES; L'installation doit être faite par un
- Page 6 – Conseils d'installation; Installation de la plaque murale du capteur à distance
- Page 7 – CÂBLAGE; FONCTIONNEMENT
- Page 8 – FICATION
- Page 9 – INSTRUCCIONES DE INSTALACIÓN; Sensor remoto para interiores C7189U; APLICACIÓN; Este producto debe ser instalado por un
- Page 10 – INSTALACION; Consejos para la instalación; Instalación de la placa para pared del sensor remoto
- Page 11 – CABLEADO; FUNCIONAMIENTO
- Page 12 – VERIFICACION
INSTALLATION INSTRUCTIONS
69-1710EFS-1
C7189U Remote Indoor Sensor
(USE WITH VISIONPRO
®
THERMOSTATS)
APPLICATION
This indoor sensor is designed to sense temperature at a remote location and send this information to the VisionPRO
Thermostat. This sensor can be used as a stand alone sensor or as part of an averaging network. Once a remote
indoor temperature sensor is connected to the thermostat, the thermostat's sensor is no longer used. The thermostat's
installer setup should be modified to tell the thermostat that remote indoor temperature sensor(s) have been used. The
Inside temperature reading on the thermostat's display will be the remote sensor(s) temperature location(s).
Fig. 1. C7189U Remote Indoor Sensor
SPECIFICATIONS
Operating Ambient Temperature Range:
45 to 88°F (7.2 to 32°C).
Display Range:
0 to 99°F (-18 to 37°C).
Sensor Accuracy:
+/-1.5°F at 70°F (+/-.84 at 21°C)
Operating Relative Humidity:
5% to 95% non-condensing.
Finish:
White.
Resistance Characteristics:
Negative temperature coefficient (NTC). Resistance
decreases as the temperature increases.
Dimensions in inches (mm):
1 1/2 (38) wide x 2 1/4 (57) high x 3/4 (19) deep.
Distance:
Maximum distance between thermostat and sensor is
200 feet.
Must be installed by a trained,
experienced technician
• Read these instructions carefully. Failure to follow
these instructions can damage the product or cause a
hazardous condition.
• Check the specification in this booklet to verify that
this product is suitable for the application.
• Always test for proper operation after installation
M24055
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Honeywell C7189U
Summary
C7189U REMOTE INDOOR SENSOR 69-1710EFS-1 2 INSTALLATION Installation Tips Install the sensor about 5 feet (1.5m) above the floor in an area with good air circulation at average temperature. Maximum distance between remote sensor and the thermostat is 200 feet. See Fig. 2. CAUTION Electrical Hazard C...
C7189U REMOTE INDOOR SENSOR 3 69-1710EFS-1 WIRING The sensor can be used to provide one remote sensor (see Fig. 6) or as a temperature averaging network with multiple sensors connected (see Fig. 7). The thermostat is not part of the average network. CAUTION ELECTRICAL HAZARD. Can cause electrical sh...
C7189U REMOTE INDOOR SENSOR Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 http://yourhome.honeywell.com ® U.S. Registered Trademark© 2005 Honeywell Inter...