Honeywell 2101 - User Manual

Honeywell 2101

A User Manual for Honeywell’s L4080 and L8080 immersion-type hydronic heating controllers covers their core function as temperature-regulating devices for boiler systems, emphasizing adjustable set points and safety mechanisms like diaphragm-actuated snap switches. The documentation highlights key operational principles–such as thermal cutoff via liquid expansion–and provides technical details on electrical ratings, pressure/temperature limits, and installation requirements, including mounting dimensions and wiring configurations for various power supply types. Safety considerations, including proper field verification before deployment, are also addressed to ensure reliable performance in heating applications.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
Page: / 7

Table of Contents:

  • Page 1 – Aquastat Controller Features and Mechanism
  • Page 2 – Temperature Control Model Specifications and Ordering
  • Page 3 – Thermostatic Switch Technical Specifications and Dimensions
  • Page 4 – Boiler Heating Element Installation Procedures
  • Page 5 – Powerpile System Wiring Hookup Diagrams
  • Page 6 – L4080F/G Powerpile Control Wiring Configurations
  • Page 7 – Temperature Control Unit Operation and Safety
Loading the manual
Page 1

-

0

THE L4080 AND L8080 ARE IMMERSION
TYPE

CONTROLLERS

FOR HYDRONIC

HEATING SYSTEMS THAT TURN OFF THE
BURNER WHENEVER THE BOILER WATER

TEMPERATURE

RISESTOTHESET

POINT.

0 L4080 High Limit Aquastat Controller

has

adjustable

set point.

Cl L4080

models

available

for use with

immersion

wells or for direct immersion

if

faster response

is needed.

0 A factory-set

stop is available on L4080 to

prevent

setting

the control

at too high a

temperature.

Cl L4080 models available with second limit
switch to shut off all gas to the burner.

III L8080 EC0 gas shutoff has fixed set point.

0 Liquid fill in sensing element expands as

the boiler temperature

rises.

Cl At the set point temperature, a diaphragm-

actuated

snap switch

breaks

the power

supply to the burner primary control.

SM.

REV.

4-66m

Form Number

60-2101-2

@Honeywell Inc. 1966

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

Helpful for 5 of 5 readers

About this manual

Brand
Honeywell
Model
2101
Document type
User Manual
Language(s)
English
Pages
7
File size
1.4 MB
Format
PDF

Other Manuals for Honeywell 2101

Summary

Page 1 - Aquastat Controller Features and Mechanism

Details on immersion-type controllers for hydronic heating systems, including adjustable set points, stop limits, limit switches, and the mechanism involving liquid expansion and a diaphragm-actuated snap switch. Model numbers L4080B,D,F,G and L8080A are referenced.

Page 2 - Temperature Control Model Specifications and Ordering

Specifications and ordering information for temperature control models, detailing model descriptions, case features, immersion well requirements, available temperature ranges, and customer service contact details.

Page 3 - Thermostatic Switch Technical Specifications and Dimensions

Technical specifications, electrical ratings, pressure and temperature ratings, certification information, and installation dimensions for the L4080 and L8080 series thermostatic switches, including mounting options.

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.