  • Page 5 – Electric; breaker, or unplug cord at wall receptacle.; Gas
  • Page 6 – REPLACEMENT; ELECTRIC
  • Page 7 – Tighten the compression nut hand tight and then a half turn; Excess force will damage temperature probe.
  • Page 20 – Heating elements should never be energized without
  • Page 29 – securing the autolift PC board bracket to the frame and remove
Loading the manual

Model OFE/OFG-321,322,323,324


SECTION 2. MAINTENANCE



2-1. INTRODUCTION

This section provides procedures for the checkout and replacement

of the various parts used within the fryer. Before replacing any

parts, refer to the Troubleshooting Section. It will aid you in

determining the cause of the malfunction.

2-2. MAINTENANCE HINTS

1. You may need to use a multimeter to check the electric

components.

2. When the manual refers to the circuit being closed, the

multimeter should read zero unless otherwise noted.


3. When the manual refers to the circuit being open, the

multimeter will read infinity.


2-3 HIGH TEMPERATURE
LIMIT CONTROL

The high temperature limit control is a safety, manual reset control

(Gas Units)

that senses the temperature of the shortening. If the shortening

temperature

exceeds

425

°

F (218

°

C), this switch will open

and shut off heat to the frypot. When the temperature of the

shortening drops to a safe operation limit, the control must be

manually reset by pressing the red reset button. The red reset

button is located under the control panel, in the front of the fryer.

This will allow heat to be supplied to the frypot once again.


Checkout

Before replacing a high temperature limit control, check to see

that

its

circuit

is

closed.

The shortening temperature must be below 380

°

F

(193

°

C) to accurately perform this check.

Checkout:

1.

Remove electrical power supplied to fryer.

To avoid electrical shock or property damage, move the

POWER switch to OFF and disconnect main circuit

breaker,

or

unplug

cord

at

wall

receptacle.

2.

Remove the control panel.

203

2-1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 5 - Electric; breaker, or unplug cord at wall receptacle.; Gas

Model OFE/OFG-321,322,323,324 2-5. POWER SWITCH (Continued) 4. With control panel removed, and the wires off the switch, push in on tabs on the switch to remove from panel. 5. Replace with new switch, and reconnect wires to switch. 6. Replace the control panel. 2-6. TEMPERATURE PROBE The temperature...

Page 6 - REPLACEMENT; ELECTRIC

Model OFE/OFG-321,322,323,324 2-6. TEMPERATURE PROBE REPLACEMENT (Continued) ELECTRIC GAS 2-6 606

Page 7 - Tighten the compression nut hand tight and then a half turn; Excess force will damage temperature probe.

Model OFE/OFG-321,322,323,324 2-6. TEMPERATURE PROBE 7. Tighten the compression nut hand tight and then a half turn REPLACEMENT with wrench. (Continued) Excess force will damage temperature probe. 8. Connect new temperature probe to PC board and replace control panel. 9. Replace shortening. 10. Turn...