Henny Penny HMR-104 - Manual
Henny Penny HMR-104 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – CONNECTION; This unit must be adequately and safely grounded. Refer to; International units are; not; supplied with cord and plug, and
- Page 3 – *Well modules can be arranged in opposite order
- Page 6 – INSTALLATION; Slide bracket off from around the 2 acorn nuts.
- Page 7 – Place glass in divider track as shown.
- Page 8 – Step 1
Model HMR-103,104,105,106,107
To remove the heated merchandiser from the carton, you should:
1. Carefully cut banding straps.
2. Open flaps of carton and remove packing.
3. Lift carton from unit.
4. Remove four bolts mounting the merchandiser to the skid.
5. If installing the unit on a merchandiser base, use existing bolts to
mount unit.
6. Unpack doors, cutting board, and pan supports, and install.
7. The heated merchandiser is now ready for location and setup.
203
2-1
SECTION 2. INSTALLATION
2-1. INTRODUCTION
This section provides the installation instructions for the Henny
Penny Heated Merchandiser.
Installation of this unit should be performed only by a qualified
service technician.
Do not puncture the heated merchandiser with any objects
such as drills or screws as component damage or electrical
shock could result.
2-2. UNPACKING
The Henny Penny Heated Merchandiser is tested, inspected and
expertly packed to ensure arrival at its destination in the best possible
condition. The unit has been bolted to wooden skid. All items have
been packed and taped inside of the unit. The unit is then packed
inside a triple wall corrugated carton with sufficient padding to with-
stand normal shipping treatment.
Any shipping damage should be noted in the presence of the
delivery agent and signed prior to his or her departure.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Model HMR-103,104,105,106,107 NEMA NUMBERS: Model 208/240-1 ph 208-3 ph 240-3 ph 107 14-50P L21-30P Hardwire 106 14-50P L21-30P Hardwire 105 14-50P L21-30P Hardwire 104 L14-30P L21-20P Hardwire 103 L14-30P L21-20P Hardwire 2-3. ELECTRICAL CONNECTION The heated merchandiser is available from the fact...
Model HMR-103,104,105,106,107 2-4. ELECTRICAL DATA TABLE COMBI- AMPS COMBI- AMPS MODEL NATION VOLTS KW 1 PHASE 3 PHASE MODEL NATION VOLTS KW 1 PHASE 3 PHASE HMR-107 7S 120/208 5.0 24 18 HMR-107 3F/2S/2F* 120/208 6.0 29 19 6.7 32 22 7.8 37 23 120/240 5.0 16 16 120/240 6.0 25 17 7.0 29 20 8.1 34 21 22...
Model HMR-103,104,105,106,107 2-6. CENTER GLASS These are the instructions for installing the center glass on units INSTALLATION that are combination, self-serve and standard merchandisers. 1. Notice the location of the bracket on unit, as indicated. 2. Using a 3/8” socket, or nut driver, loosen the...