Installation

Refer to the following pages for important information regarding the
installation of LCS and LCG ClimaPlus Combis. It is recommended
that installation be accomplished by a certified and properly trained
technician.

NOTE:

When installing a ClimaPlus combi, humidity calibration must

be performed. This process takes approximately 45-60 minutes. (page 62)

Site, leveling

1) Check for any transport damages.

Should there be any signs of transport

damage immediately inform your dealer/freight forwarder.

2) Check installation site.

Check entrance clearance.

Minimum entrance space needed without pallet:

Model 6 & 10:

35

1

2

in. (902 mm)

Model 1020:

49

5

8

in. (1262 mm)

Model 20:

39

7

8

in. (1012 mm)

Model 40:

52

1

2

in. (1332 mm)

Floor at installation site must be level.

Cold water line in place. (page 63)

2 in. (50 mm) drain connection installed.

Max. drain height for floor units: 4 in. (100mm)

Electrical power supply/protective measures installed and sized correctly.
(page 60-61)

3) Remove all cartons, packing materials, documents etc. from the interior cabinet.
4) Remove grid shelves/trolley from cabinet.
5) Take unit off the pallet.

Moving unit without pallet: Sizes 6, 10, 1020 (Fig. 1)

Moving unit without pallet: Sizes 20, 40 (Fig. 2)

Minimum clearance sides and back:
2 in. (50 mm)

Service clearance, left side:
20 in. (500 mm)

Clearance for door opening:

Model 6 & 10:

20

1

2

in. (521 mm)

Model 1020:

29

1

2

in. (749 mm)

Model 20:

28

3

4

in. (730 mm)

Model 40:

30

3

4

in. (781 mm)

Fig. 1

Fig. 2

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Electrical; ) Electrical connection; Connected load for electric units:

60 Unit weights: LCS 6: 270 lbs. (123 kg) LCG 6 335 lbs. (152 kg) LCS 10 334 lbs. (152kg) LCG 10 384 lbs. (174 kg) LCS 1020 484 lbs. (220 kg) LCG 1020 584 lbs. (265 kg) LCS 20 686 lbs. (312 kg) LCG 20 798 lbs. (362 kg LCS 40 972 lbs. (442 kg) LCG 40 888 lbs. (403 kg) 6) Installation models 6, 10, 10...

Page 3 - INSTALLATION

61 Choose conductor size according above tables and your local regulations. IMPORTANT Gas units are voltage specific. Supply voltage must match voltage rated on data plate. ■ Gas units are supplied with grounded power cord and plug. ■ Electric units are NOT supplied with power cord. To connect power...

Page 5 - Water supply; Optional Treated Water Connection

63 Fig. 12 Fig. 13 C B A Fig. 14 WA WA WZ INSTALLATION Water supply 9) Drain Connection (WA) ■ For drain connection (Fig. 12) use only steam temperature resistant pipe, diameter 2 in. (50 mm) and constant slope 5%. No hose should be used. ■ Direct drain connection is possible, ventilated gap is an i...