5-1. TROUBLE SHOOTING GUIDE
Problem Cause Correction
POWER switch ON but fryer
• Open circuit
•
Plug fryer in
completely inoperative
•
Check breaker or fuse at supply
box
Shortening will not
•
Open high limit
•
Reset high limit per
heat but lights are on.
circuit
High Limit Temperature
Error message “E10”
Control Section
•
Drain valve open
•
Turn drain valve handle to
Error message “E15”
closed position
Foaming or boiling
•
Water in shortening
•
At end of Cook Cycle, drain
over of shortening
shortening and clean
•
Improper or bad
•
Use recommended shortening
shortening
•
Improper filtering
•
Refer to the procedure covering
filtering the shortening
•
Improper rinsing after
•
Clean and rinse the frypot, then
cleaning the fryer
dry thoroughly
Shortening will not
•
Drain valve clogged
•
Open valve, force cleaning
drain from frypot
with crumbs
brush through drain
Filter switch on,
•
Motor thermal
•
Reset thermal switch per section
motor does not run
protector tripped
on Filter Pump Motor
Protector – Manual Reset