Table of Contents:
- Page 2 – DO NOT; ALERTED; SAFETY AND WARNING INFORMATION
- Page 3 – TABLE OF CONTENTS
- Page 4 – Standing Pilot Ignition; Service Parts
- Page 5 – BAY-38HV Service Parts List / Liste des pièces de rechange; STANDING PILOT IGNITION ONLY / ALLUMAGE UNE VEILLEUSE SEULEMENT; L'information fournie dans cette brochure
- Page 6 – Appliance Certification; Installers; Certification; Approvals and; High Altitude Installations; Systems registered
- Page 7 – Getting Started; Introducing the Heat-N-Glo Gas Fireplaces; Pre-install Preparation
- Page 9 – Installing the Fireplace; Step 1. Locating the Fireplace; Vertical Sections; Constructing the Chase; MUST
- Page 10 – Figure 4. Vertical and Horizontal Vent Runs; Vertical Vent Runs; Figure 3. Framing Dimensions; Step 2. Framing the Fireplace; CAUTION: MEASURE FIREPLACE DIMENSIONS AND; WARNING: FRAMING DIMENSIONS ASSUME
- Page 12 – Step 3. Installing the Vent System; Identifying Vent Components; Termination Kits
- Page 13 – For vertical vent runs of
- Page 14 – For vertical vent runs of 10
- Page 15 – VENTING WITH TWO; Figure 11. Venting with Two 90° Elbows
- Page 16 – Figure 12. Venting with Two 90° Elbows
- Page 17 – Venting with three 90° elbows
- Page 18 – Figure 14. Venting with three 90° elbows; For vertical vent runs of 10 feet or greater
- Page 19 – B. Installing Vent Components
- Page 20 – NOTE: Model SLK-01TRD does not need an exterior
- Page 21 – NOTE: Keep insulation away from the vent pipe at least
- Page 25 – Standing Pilot Ignition
- Page 26 – Pressure
- Page 27 – Step 8. Wiring the Fireplace; This appliance
- Page 28 – Optional Accessories; Figure 31. Direct Spark Ignition Wiring Diagram; CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
- Page 30 – and Ember Material; CAUTION: IT IS STRONGLY RECOMMENDED THAT
- Page 31 – Step 11. Before Lighting the Fireplace; Step 12. Lighting the Fireplace; GLASS SPECIFICATIONS:; TEMPERED
- Page 32 – Maintaining and Servicing Your Fireplace; Fireplace Maintenance
1
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
-
What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Model:
BAY-38HV
Installers Guide
WARNING: IMPROPER INSTA L L A -
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
Underwriters
Laboratories Listed
287-900E 5/01
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS
INSTALLERS
GUIDE
MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Please contact your Heat-N-Glo dealer for any
questions or concerns. For the number of your
nearest Heat-N-Glo dealer, please call 952-985-6000.
Printed in U.S.A. Copyright 2001,
Heat-N-Glo, a division of Hearth Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 ! These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or components MAY BE USED . This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a...
3 TABLE OF CONTENTS Safety and Warning Information ................................................ 2 Service Parts Lists ..................................................................... 4 Section 1: Approvals and Codes ............................................... 6 Appliance Certification ....
4 BAY-38HV and BAY-38HV-DSI Exploded Parts Diagram / Vue éclatée des pièces * Part number list on following page.* La liste des numéros de pièce se trouve à la page suivante. 17 18 19 20 7 12 13 15 16 14 3 8 1 9 6 2 11 10 5 Standing Pilot Ignition DSI Ignition 3 Service Parts 4