Page 2 - Installers Guide; DO NOT; Owners Guide; ALERTED; Safety and Warning Information
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 2 These units MUST use one of the vent systems described in the Installing the Fireplace section ofthe Installers Guide . NO OTHER vent systems or components MAY BE USED . This gas fireplace and vent assembly MUST ...
Page 3 - Table of Contents
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 3 Table of Contents Safety and Warning Information .................................................. 2 Service Parts List ......................................................................... 4 Approvals and C...
Page 4 - Log Assembly; Service Parts; Grate
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 4 6 Log Assembly (NG, LP) Exploded Parts Diagram Service Parts Pier-HV-IPI Beginning Manufacturing Date: 6-03Ending Manufacturing Date: ______ 5 2 1 3 4 Grate Bar
Page 5 - ITEM; supply serial and model numbers to ensure correct service parts.
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 5 AVAILABLE TO SHIP IN 24 HOURS ITEM DESCRIPTION SERIAL # PART NUMBER Burner Orifice NG (#33DMS) 582-833 Y Burner Orifice LP (#50DMS) 582-850 Y 1 End Glass Assembly GLA-MS Y 2 Glass Door Assembly GLA-6TROC Y 3 Burn...
Page 8 - Part number list on following page.
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 8 Part number list on following page. 7 Log Assembly 15 (NG, LP) Exploded Parts Diagram Service Parts LCOR-HV-IPI Beginning Manufacturing Date: 6-03 Ending Manufacturing Date: ______ 1 2 3 4 5 6 15
Page 13 - Appliance Certification; The Heat & Glo fireplace models discussed in this; Certification; Underwriters Laboratories; Installation Codes
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 13 Appliance Certification The Heat & Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. Certification MODELS: PIER-HV...
Page 14 - The following requirements reference various; G. Requirements for the Commonwealth of
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 14 For all side wall horizontally vented gas fueled equipmentinstalled in every dwelling, building or structure used inwhole or in part for residential purposes, including thoseowned or operated by the Commonwealth...
Page 15 - Getting Started; Introducing the Heat & Glo Gas Fireplaces; Pre-install Preparation; Do not install any
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 15 2 Getting Started Introducing the Heat & Glo Gas Fireplaces Heat & Glo direct vent gas fireplaces are designed to oper-ate with all combustion air siphoned from outside of thebuilding and all exhaust gas...
Page 19 - Installing the Fireplace; Step 1. Locating the Fireplace; Fireplace Locations/Dimensions with
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 19 3 Installing the Fireplace Step 1. Locating the Fireplace The diagram below shows space and clearance require-ments for locating a fireplace within a room. Figure 4A. Fireplace Dimensions and Locations 36" G...
Page 20 - Step 2. Framing the Fireplace
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 20 Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Sides or Ends .......... 36 .................... 914 Floor ................................... 0 ....................... 0Rear Vent ...
Page 21 - Model; Framing Dimensions
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 21 Framing should beconstructed of 2 X 4lumber or heavier. Model A B C D E PIER-HV-IPI 42-1/8 42-1/2 23 35-3/4 48 ST-HV-IPI 47-5/8 42-1/2 23 35-3/4 48 L&RCOR-HV-IPI 42-1/8 42-1/2 28-3/4 35-3/4 48 Figure 5. Fram...
Page 23 - Step 3. Installing the Vent System
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 23 Figure 7. Vent System Components and Termination Kits Step 3. Installing the Vent System A. Vent System Approvals These models are approved to use DVP series direct ventpipe components and terminations (see Figu...
Page 24 - On vertical venting; Flue Restrictor Instructions; BREAK; . Center the Flue Restrictor on vent and secure in; CAP; Match the amount of; Vertical; FLUE
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 24 Figure 8 NOTE: On vertical venting configurations you maywant to install the flue re-strictor (385-128). See fluerestrictor installation in-structions. Flue Restrictor Instructions 1. Locate the Flue Restrictor ...
Page 26 - Figure 15. Venting with Two 90° Elbows
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 26 Figure 15. Venting with Two 90° Elbows H 1 H V V V 1 H NATURAL GAS VENTING WITH TWO 90° ELBOWS V (FT.) H + H 1 (FT.) 90 0 Elbow on top 2.5’ MAX. (64mm) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1....
Page 27 - Figure 17. Venting with Two 90° Elbows
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 27 Figure 16.Venting with Two 90° Elbows Figure 17. Venting with Two 90° Elbows H1 V H V H H 1 NATURAL GAS VENTING WITH TWO 90° ELBOWS V (FT.) H + H 1 (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (...
Page 28 - Figure 18. Venting with three 90° elbows
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 28 Figure 18. Venting with three 90° elbows H H 1 H 2 V H V H 1 V 1 NATURAL GAS VENTING WITH THREE 90° ELBOWS V + V 1 (FT.) H + H 1 + H 2 (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN...
Page 29 - Figure 19. Venting with three 90° elbows; NATURAL GAS
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 29 Figure 19. Venting with three 90° elbows V H H 1 V 1 V H H 1 V 1 NATURAL GAS VENTING WITH THREE 90° ELBOWS V + V 1 (FT.) H + H 1 (FT.) 90 0 Elbow on top 2.5’ MAX. (64mm) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (...
Page 30 - Venting Out Vertically
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 30 1. Attach the First Vent Component to the Starting Collars To attach the first vent component to the starting collarsof the fireplace: • Slide the first vent section onto the unit and push in until they snap loc...
Page 32 - For Horizontal Terminations -
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 32 Figure 26. Ceiling Firestop (Ceiling Side) If the area above the ceiling is NOT an attic, position and secure the ceiling firestop on the ceiling side of the previouslycut and framed hole. If the area above the ...
Page 33 - = AREA WHERE TERMINAL IS NOT PERMITTED; Figure 29. Vent Termination Minimum Clearances; public; N O T E 3
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 33 V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 29. Vent Termination Minimum Clearances A = 12" ....................... clearances above grade, veran- da, porch, deck or ...
Page 35 - Step 5. The Gas Control System; Figure 32. Gas Control System; IPI PILOT; THE FIREPLACE JUNCTION BOX IN A IPI SYSTEM.
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 35 Step 4. Positioning, Leveling, and Securingthe Fireplace • Place the fireplace into position. • Level the fireplace from side to side and from front to back. • Shim the fireplace with non-combustible material, s...
Page 36 - Pressure; Figure 33. Gas Supply Line
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 36 • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between thepipe and the outer casing. • At the gas line access hole the gap between the supply piping and gas...
Page 37 - Appliance Requirements; Note; WARNING
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 37 Step 8. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensedelectrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB-SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-VENT ACCIDENTAL FIREPLACE ...
Page 39 - Figure 38. Junction Box Wired to Wall Switch; Wall Switch Installation for Fan (Optional)
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 39 If the box is being wired to a wall mounted switch for usewith a fan (See Figure 38): • The power supply for the appliance must be brought intoa switch box. • The power can then be supplied from the switch box t...
Page 40 - materials may be used to cover the black fireplace front.; F. MINIMUM SEALANT MATERIAL; Hearth Extensions; r e q u i r e h e a r t h; Figure 41. Sealant Material
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 40 Step 9. Finishing Figures 39 and 40 show the minimum vertical and correspondingmaximum horizontal dimensions of fireplace mantels or othercombustible projections above the top front edge of the fireplace. SeeFig...
Page 41 - overlap onto the front face. The joints; FULL OPEN
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 41 Installing the Trim Combustible materials may be brought up to the specifiedclearances on the side and top front edges of the fireplace,but MUST NEVER overlap onto the front face. The joints between the finished...
Page 43 - Placing the Ember Material; To place the ember material:; NOT; Replace the glass door and a front trim door on the unit.; Figure 50. Placement of the Ember Material
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 43 Placing the Ember Material Ember material is shipped with this gas fireplace. The baglabeled Glowing Ember (050-721) is standard glowing em-ber material. To place the ember material: • Remove the glass door from...
Page 44 - Step 11. Before Lighting the Fireplace; Step 12. Lighting the Fireplace
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 44 Step 11. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace. Review safety warnings and cautions • Read the Safety and Wa...
Page 45 - Maintaining and Servicing Your Fireplace; Fireplace Maintenance; Placing Ember Material